journal article·2013-10

Numerical modelling of the hygro-thermal response of timber bridges during their service life: A monitoring case-study

Stefania Fortino, Alessandra Genoese, Andrea Genoese, Lina Nunes, Pedro Palma

Publisher page

Abstract

The monitoring of timber bridges during their service life is important for the maintenance plans of these structures. Numerical modelling can integrate the monitoring techniques by reducing the needed inspections and the maintenance costs. In this paper a 3D computational model based on a well assessed multi-Fickian theory is implemented in Abaqus FEM code. The hygro-thermal response of a timber pedestrian bridge is simulated during a period of its service life. The numerical results are in agreement with measurements taken by a sensor-based technique. Conclusions are given on the moisture gradients which could generate the so-called moisture induced stresses (MIS).
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Hygrothermal properties of building materials · Structural Health Monitoring Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Aasheim E. Nordic timber bridge program – an overview, international wood engineering conference, New Orleans; 1996.
2. Research on and development of wooden bridges in Finland10.2749/101686600780481455 ↗
3. Gustafsson A, Pousette A, Björngrim N. Health monitoring of timber bridges. In: Proc int conf on timber bridges, September 12–15, Lillehammer, Norway; 2010.
4. Dinwoodie · 1979
5. Tannert T, Mueller A, Vogel M. Structural health monitoring of timber bridges. In: Proc int conf on timber bridges, September 12–15, Lillehammer, Norway; 2010.
6. Tannert T, Berger R., Mueller A, Vogel M. Remote moisture monitoring of timber bridges: a case study. In: Proceedings of the 5th international conference on structural health monitoring of intelligent infrastructure (SHMII-5) 2011, 11–15 December 2011, Cancún, México; 2011.
7. Mechanical response of wood perpendicular to grain when subjected to changes of humidity10.1007/s00226-001-0130-4 ↗
8. Predicting moisture state of timber members in a continuously varying climate10.1016/j.engstruct.2011.04.029 ↗
9. Moisture-induced stresses perpendicular to grain in timber sections exposed to European climates10.1016/j.engstruct.2011.06.018 ↗
10. Jönsson · 2005
11. Frühwald · 2008
12. Moisture-induced stresses in spruce cross-laminates10.1016/j.engstruct.2009.11.006 ↗
13. A revised multi-Fickian moisture transport model to describe non-Fickian effects in wood10.1515/HF.2007.085 ↗
14. COST Action E55. Modelling of the performance of timber structures. ; 2006–2011.
15. Implementation of moisture hysteresis in multi-Fickian moisture transport10.1515/HF.2007.113 ↗
16. Frandsen · 2007
17. A multi-scale approach for simulation of transient moisture transport processes in wood below the fiber saturation point10.1016/j.compscitech.2011.08.004 ↗
18. Abaqus/Standard · 2008
19. Abaqus/Standard · 2008
20. NMR imaging study and multi-Fickian numerical simulation of the moisture transfer in Norway spruce samples10.1016/j.engstruct.2011.04.011 ↗
21. A 3D moisture-stress FEM analysis for time dependent problems in timber structures10.1007/s11043-009-9103-z ↗
22. Ormarsson · 1999
23. Modelling the hygrothermal stress in curved glulam beams10.1243/03093247JSA563 ↗
24. Parameter influence on moisture induced eigen-stresses in timbers10.1007/s00107-009-0377-2 ↗
25. Stamm · 1964
26. A critical discussion of the physics of wood–water interactions10.1007/s00226-012-0514-7 ↗
27. Ressel · 2006
28. Measurement system for with internal conductively glued electrodes10.1016/j.buildenv.2007.10.002 ↗
29. Forsén H, Tarvainen V. Accuracy and functionality of hand held wood moisture content meters. VTT, Espoo, Research, Report 79; 2000.
30. Frandsen · 2005
31. Siau · 1984