journal article·2017-11

Recovering flexural performance of thermally damaged concrete beams using NSM CFRP strips

Rami H. Haddad, Oubaida A. Almomani

Publisher page

Abstract

Abstract The potential of recovering the flexural performance of thermally damaged concrete beams using near surface mounted (NSM) carbon fiber reinforced polymer (CFRP) strips was experimentally investigated. Twenty reinforced concrete beams (150 × 250 × 1400 mm) were cast then cured for 28 days in moist burlap. A set of ten beams were heated at 600 °C for 2 h using an electrical furnace whereas those of the second set were left in laboratory air. Four pairs of beams from each set were repaired/strengthened at their tension side using similar configurations of NSM CFRP strips. Duplicate beams of each set were tested as controls. The mechanical performance of different beams was evaluated under four-point loading test setup including measurement of strain in NSM CFRP strips and slippage between NSM CFRP strips and concrete. Moreover, cracking and failure modes were monitored and characterized. Intact/strengthened and heat-damaged/repaired beams showed improved load capacity and toughness, yet experienced reductions in ductility and toughness as compared to control ones. Different performance indicators revealed good potential of repairing heat-damaged beams using NSM CFRP strips. End-cover separation failure mode was observed for both strengthened as well as repaired beams. Analytical predictions of ultimate load capacity for different beams confirmed experimentally obtained results.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Study on compressive mechanical capability of concrete after high temperature exposure and thermo-damage constitutive model10.1016/j.conbuildmat.2014.06.052 ↗
2. Residual compressive strength and freeze–thaw resistance of ordinary concrete after high temperature10.1016/j.conbuildmat.2013.12.089 ↗
3. Experimental study on residual flexural behavior of reinforced concrete beams after exposure to fire
4. Structural damage evaluation of reinforced concrete beams exposed to high temperatures10.1177/1042391512474666 ↗
5. An approach for evaluating residual capacity of reinforced concrete beams exposed to fire10.1016/j.engstruct.2015.11.047 ↗
6. Effect of elevated temperature on bond between steel reinforcement and fiber reinforced concrete10.1016/j.firesaf.2007.11.002 ↗
7. Repair of heat-damaged reinforced concrete T-beams using FRC jackets10.1680/macr.2007.59.3.223 ↗
8. Repair of heat-damaged reinforced concrete slabs using fibrous composites materials10.1016/j.conbuildmat.2010.09.033 ↗
9. Plate separation and anchorage of reinforced concrete beams strengthened by epoxy-bonded steel plates
10. Flexural behavior of pre-cracked reinforced concrete beams strengthened externally by steel plates
11. Effect of advanced composites in repairing heat-damaged RC columns10.1617/s11527-013-0022-8 ↗
12. Axial capacity of post-heated square columns wrapped with FRP composites10.1016/j.cemconcomp.2011.03.011 ↗
13. Repairing reinforced concrete slabs using composite layers10.1016/j.matdes.2014.02.015 ↗
14. Bond behavior of FRP NSM systems in concrete elements10.1016/j.compositesb.2011.10.017 ↗
15. Near surface mounted strengthening of RC beams using basalt fiber reinforced polymer bars10.1016/j.conbuildmat.2016.02.046 ↗
16. Flexural performance of RC beams strengthened with near surface mounted CFRP strips
17. Recovering shear capacity of heat-damaged beams using NSM CFRP strips10.1016/j.conbuildmat.2015.12.152 ↗
18. Flexural behavior of fire-damaged reinforced concrete slabs repaired with near-surface mounted (NSM) carbon fiber reinforced polymer (CFRP) rods10.3151/jact.13.15 ↗
19. Design formula to evaluate the NSM FRP strips shear strength contribution to a RC beam10.1016/j.compositesb.2013.09.001 ↗
20. Flexural response of reinforced concrete (RC) beams strengthened with near surface mounted (NSM) fiber reinforced polymer (FRP) bars10.1016/j.compstruct.2013.10.051 ↗
21. An experimental study on reinforced concrete beams strengthened with prestressed near surface mounted CFRP strips10.1016/j.engstruct.2014.08.007 ↗
22. Bond strength of near surface mounted FRP plates for retrofit of concrete structures10.1016/j.compstruct.2012.08.038 ↗
23. Experimental and numerical investigation for the flexural strengthening of RC beams using near-surface mounted steel or GFRP bars10.1016/j.conbuildmat.2012.09.107 ↗
24. Bond of NSM systems in concrete strengthening – examining design issues of strength, groove detailing and bond-dependent coefficient10.1016/j.conbuildmat.2013.06.069 ↗
25. Interaction forces in RC beams strengthened with near-surface mounted rectangular bars and strips10.1016/j.compositesb.2012.09.038 ↗
26. Shear strengthening of concrete members using NSM method10.1016/j.proeng.2013.09.056 ↗
27. NSM shear strengthening technique with CFRP laminates applied in high-strength concrete beams with or without pre-cracking10.1016/j.compositesb.2011.09.006 ↗
28. Flexural response of reinforced concrete members strengthened with near-surface-mounted CFRP strips
29. Investigation of bond in concrete structures strengthened with near surface mounted carbon fibers reinforced polymer strips10.1061/(ASCE)1090-0268(2003)7:3(248) ↗
30. American Concrete Institute · 2008
31. American Society for Testing and Materials International (ASTM), West Conshohocken, PA, 2004.
32. ACI Manual of Concrete Practice, Standard practice for selecting proportions for normal, heavyweight, and mass concrete (ACI 211.1), Part I: Materials and General Properties of Concrete, Detroit, Michigan, 2008.
33. Concrete stress distribution in ultimate strength design
34. Eurocode 2, Design of concrete structures-Part 1-2. Europian Committee for Standardization, Avenue Marnix 17 – B-1000, Brussels, Belgium, 1995.