Evaluation of corrosion-induced crack and rebar corrosion by ultrasonic testing
Source abstract
Abstract
Abstract Recently, the maintenance of concrete structures has become important for the sustainability of infrastructure. Steel-bar (rebar) corrosion is one of typical deteriorations to reduce the service life of concrete structures. Corrosion products of rebar cause cracking in concrete. When these cracks reach to the concrete surface, the damage of rebar corrosion is readily recognized by visual inspection. In this case, however the damage is referred to as the acceleration stage. In order to evaluate the performance of concrete members and structures, it is important to evaluate the corrosion of rebar as early as possible. Thus, the corrosion of rebar is often detected directly to remove cover concrete. In this concern, nondestructive evaluation is important to detect the corrosion and corrosion-induced cracking inside concrete at the dormant and the initiation stage prior to the acceleration stage. In the acceleration stage, it is important to detect the corrosion precisely and to evaluate the cracking of concrete. In order to detect rebar corrosion at early stage, ultrasonic testing is applied. The damage of concrete and cracking under an electrolytic corrosion test is estimated.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Infrastructure Maintenance and Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (11)
Show source-provided references
1. ASTM C876. Standards test method for half-cell potentials of uncoated reinforcing steel in concrete. Annual book of ASTM Standard; 1991.
2. Ohtsu M. Detection and identification of concrete cracking in reinforced concrete by AE. Review of progress in quantitative NDE. In: AIP conference proc. 657, 22B; 2003. p. 1455–62.10.1063/1.1570302 ↗
3. AE monitoring of corrosion process in cyclic wet–dry test10.1016/j.conbuildmat.2010.05.006 ↗
4. Sansalone · 1997
5. Detection of the corrosion damage of rebar in concrete using impact-echo method10.1016/S0008-8846(01)00569-5 ↗
6. BS1881 part 203. Recommendations for measurement of velocity of ultrasonic pulses in concrete, British Standards; 1990.
7. JCMS-IIIB5704. Test method for compressive strength of concrete by ultrasonic waves, Federation of Construction Material Industries; 2003 [in Japanese].
8. JCMS-IIIB5705. Method for estimating surface-crack depth in concrete by ultrasonic-wave velocity, Federation of Construction Material Industries; 2003 [in Japanese].
9. Watanabe T, Miyachi T, Hashimoto C, Ohtsu M. Detecting defects in patch repaired concrete by ultrasonic method. Structural Faults and Repair 2008, (CD-ROM); 2008.
10. Evaluation of self healing effect in fly-ash concrete by ultrasonic test method10.1142/S0217979211066830 ↗
11. Detection of the corrosion damage in reinforced concrete members by ultrasonic testing10.1016/S0008-8846(98)00060-X ↗