Analytical solution for the full-range pull-out behavior of FRP ground anchors
Source abstract
Abstract
Abstract This paper attempts to predict the nonlinear pull-out response of fiber reinforced polymer (FRP) rods embedded in steel tubes filled with cement grout. Based on a tri-linear bond–slip model, the whole FRP rod is divided into three zones: linear elastic, softening, and frictional. In each zone, a set of two second-order ordinary differential equations are established in terms of the displacements of the FRP rod and steel tube and solved in an analytical manner. When the thickness of the steel tube approaches infinity, the solution can be applied to the problem of FRP rods embedded in rock. Based on the derived solution, the interfacial bond properties and snapback phenomenon are discussed. After the analytical solution is validated by comparisons with four sets of experimental data, the effects of the radius and length of FRP rods, the local peak bond stress and the residual frictional strength on the maximum pull-out load are evaluated through sensitivity analysis.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. Tensile behavior of FRP tendons for prestressed grouted anchors10.1061/(ASCE)1090-0268(2001)5:2(85) ↗
2. Design and evaluation of fiber-reinforced polymer bond-type anchorages and ground anchors10.1061/(ASCE)1532-3641(2006)6:3(166) ↗
3. On steady-state fibre pull-out I: the stress field10.1016/S0266-3538(99)00110-4 ↗
4. Field pullout testing and performance evaluation of GFRP soil nails10.1061/(ASCE)GT.1943-5606.0000457 ↗
5. Grouted anchorages for aramid fiber reinforced plastic prestressing tendons10.1139/l93-137 ↗
6. Tensile properties and pullout behaviour of AFRP and CFRP rods for grouted anchor applications10.1016/S0950-0618(00)00017-9 ↗
7. Discussion: grouted anchorages for aramid fiber reinforced plastic prestressing tendons10.1139/l94-074 ↗
8. Prediction of tensile capacity of bond anchorages for FRP tendons10.1061/(ASCE)1090-0268(2000)4:2(39) ↗
9. Pullout bond properties of fiber-reinforced polymer tendons to grout10.1061/(ASCE)0899-1561(2002)14:5(399) ↗
10. Bond strength of cement grouted glass fiber reinforced plastic (GFRP) anchor bolts10.1016/0148-9062(96)00006-X ↗
11. Analytical solution for the pull-out response of FRP rods embedded in steel tubes filled with cement grout10.1617/s11527-009-9515-x ↗
12. An analytical analysis of the full-range behaviour of grouted rockbolts based on a tri-linear bond–slip model10.1016/j.conbuildmat.2009.08.021 ↗
13. Arnol’d · 1992
14. Chen WW, Ren FF. Mechanical behavior of the bamboo-steel composite rockbolt. Report 2006BAK30B02, Lanzhou University, Lanzhou, China; 2008, [in Chinese].
15. Testing study on working mechanism of fully grouted bolts of thread steel and smooth steel