Performance criteria for the fire safe use of thermal insulation in buildings
Source abstract
Abstract
Building design can be considered as a multi-objective optimisation problem, in which many criteria are considered for determining the most favourable solution. The application of optimisation techniques requires the design criteria to be quantifiable, which sets the baseline for the application of performance-based designs. Sustainability has become the main driver in the built environment during recent decades, with energy efficiency becoming the foremost design criteria and appropriately quantified. By contrast, the approach taken for fire safety is much simplistic, relying on a series of prescriptions based on material classification and “pass–fail” criteria defined in standard fire tests. This results in deficiencies in identification of fire hazards and undermines any attempt at design optimisation. A redefinition of the failure criteria framework based on fundamental understanding of the material behaviour, including the heat transfer controlled processes governing the onset of pyrolysis, can provide a performance-based methodology for the fire safe use of insulation materials in buildings. The different hazards from insulation materials in fire are identified and a set of criteria are defined to identify likely failure modes. A series of highly instrumented large-scale experiments of a construction system involving a common combustible material are referenced to demonstrate the proposed methodology.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Wind and Air Flow Studies · Structural Analysis of Composite Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (58)
Show source-provided references
1. Applying a multi-objective optimization approach for design of low-emission cost-effective dwellings10.1016/j.buildenv.2010.07.006 ↗
2. Optimization approach of balancing life cycle cost and environmental impacts on residential building design10.1016/j.enbuild.2014.11.048 ↗
3. An evolutionary approach to generating constraint-based space layout topologies
4. Application of multi-objective genetic algorithm to optimize energy efficiency and thermal comfort in building design10.1016/j.enbuild.2014.11.063 ↗
5. Building envelope design with the objective to ensure thermal, visual and acoustic comfort conditions10.1016/S0360-1323(03)00141-0 ↗
6. Risk design optimization using many-objective evolutionary algorithm with application to performance-based wind engineering of tall buildings10.1016/j.strusafe.2014.01.002 ↗
7. On the energy performance of buildings
8. State of the art in thermal insulation materials and aims for future developments10.1016/j.enbuild.2004.05.006 ↗
9. M. Gilles, T.D. Jensen, SRI roadshow Paris 2011. (accessed February 1, 2015).
10. V.M. Brannigan, The regulation of technological innovation: the special problem of fire safety standards, FireSeat “Fire Build. Saf. Single Eur. Mark., Edinburgh, UK, 2008, pp. 20–33.
11. Fundamentals of the fire behaviour of cellular polymers10.1007/978-94-009-3443-6_4 ↗
12. A contemporary review of large-scale non-standard structural fire testing10.1186/2193-0414-2-1 ↗
13. C. Wade, Future directions in fire testing of building products. Build. a Glob. Futur. – Aust. Built Environ, Australian Building Codes Board, Gold Coast, Australia, 2003.
14. J.M. Buist, S.J. Grayson, W.D. Woolley, Fire and Cellular Polymers, 1986, ISBN: 978-94-010-8041-5 (Print) 978-94-009-3443-6 (Online). Available from: .
15. The international FORUM of fire research directors: a position paper on sustainability and fire safety10.1016/j.firesaf.2012.01.003 ↗
16. Meacham · 2012
17. BS EN 13501-1, Fire classification of construction products and building elements. Part 1: classification using data from reaction to fire tests, 2009.
18. BS EN 1363-1, Fire resistance tests – Part 1: general requirements, 2012.
19. P.H. Thomas, A.J. Heselden, M. Law, Fully-developed compartment fires -two kinds of behaviour. Fire Res Tech Pap No 18 Minist Technol Fire Off Committee, Jt Fire Res Organ FRS, London, UK ,1967, 18.
20. NFPA 5000 – Building Construction and Safety Code, 2015.
21. BS EN ISO 13823, Reaction to fire tests for building products — building products excluding floorings exposed to the thermal attack by a single burning item ,2010.
22. BS EN ISO 11925-2, Reaction to fire tests — ignitability of products subjected to direct impingement of flame. Part 2: single-flame source test, 2010.
23. BS EN ISO 1182, Reaction to fire tests for products — non-combustibility test, 2010.
24. BS EN ISO 1716, Reaction to fire tests for products — determination of the gross heat of combustion (calorific value), 2010.
25. BS 8414-1, Fire performance of external cladding systems. Test methods for non-loadbearing external cladding systems applied to the face of a building, 2002.
26. BS EN 1364-4, Fire resistance tests for non-loadbearing elements. Curtain walling. Part configuration, 2014.
27. M. Smolka, Y. Suurenbroek, Smoke and heat emissions as measures for interaction of tested elements with test environment in fire resistance testing, in: Proc. 13th Int. Interflam Conf., 2013.
28. Gas and particle effluents released from boundaries of fire compartments: first results and analyses
29. Three-dimensional simulation of a fire-resistance furnace10.3801/IAFSS.FSS.5-1009 ↗
30. Adiabatic surface temperature and the plate thermometer for calculating heat transfer and controlling fire resistance furnaces10.3801/IAFSS.FSS.9-1227 ↗
31. Normalized heat load: a key parameter in fire safety design10.1002/fam.810060108 ↗
32. ASTM E84: Standard test method for surface burning characteristics of building materials, 2014.
33. ASTM Standard E119, Test methods for fire tests of building construction and materials, 2012. http://dx.doi.org/10.1520/e0119-12a.10.1520/E0119-12A ↗
34. ISO 9705, Fire tests – full-scale room test for surface products, 1993.
35. J.P. Hidalgo-Medina, Performance-based methodology for the fire safe design of insulation materials in energy efficient buildings (Ph.D. thesis). The University of Edinburgh, 2015.
36. R.T. Long, J.L. Torero, J.G. Quintiere, A.C. Fernandez-Pello, Scale and transport considerations on piloted ignition of PMMA, in: Sixth Int. Symp. Fire Saf. Sci., 1999, pp. 567–578.10.3801/IAFSS.FSS.6-567 ↗
37. Fire performance of sandwich panels in a modified ISO 13784-1 small room test: the effect of damage and increased fire load
38. ISO 13784-1, Reaction to fire test for sandwich panel building systems. Part 1: small room test, 2014.
39. The relation of oxygen to the heat of combustion of organic compounds10.1080/14786440208635627 ↗
40. Measuring rate of heat release by oxygen consumption10.1007/BF01038449 ↗
41. Limits of flammability and premixed flames
42. Flammability characteristics of combustible gases and vapours
43. The role of thermal feedback in compartment fires10.1007/BF02590002 ↗
44. Estimating room temperatures and likelihood of flashover using fire test data correlations10.1007/BF02479583 ↗
45. Experimental study on the burning behavior of pool fires in rooms with different wall linings10.1007/s10694-011-0230-0 ↗
46. An experimental study of the effect of thermal radiation feedback on the room-burning behaviour of horizontal slabs of polyurethane foam
47. Combustion of liquid fuel in gas stream
48. J.L. Torero, A.H. Majdalani, C. Abecassis-Empis, A. Cowlard, Revisiting the compartment fire, in: 11th Int. Symp. Fire Saf. Sci., 2014.10.3801/IAFSS.FSS.11-28 ↗
49. A.H. Majdalani, Compartment fire analysis for contemporary architecture (Ph.D. thesis), The University of Edinburgh, 2014.
50. Transient plane source techniques for thermal conductivity and thermal diffusivity measurements of solid materials10.1063/1.1142087 ↗
51. Measurement of specific heat functions by differential scanning calorimetry10.1021/ac60242a011 ↗
52. ASTM E1269, Standard test method for determining specific heat capacity by differential scanning calorimetry, 2011.
53. BS 476-15, ISO 5660-1, Fire tests on building materials and structures. Method for measuring the rate of heat release of products, 1993.
54. ASTM E 2058, Standard test methods for measurement of synthetic polymer material flammability using a fire propagation apparatus (FPA), 2009. http://dx.doi.org/10.1520/E2058-09.10.1520/E2058-09 ↗
55. The heat-transfer rate inducing system (H-TRIS) test method
56. Experimental characterisation of the fire behaviour of thermal insulation materials for a performance-based design methodology
57. J.P. Hidalgo, S. Welch, J.L. Torero, Design tool for the definition of thermal barriers for combustible insulation materials, in: Proc 2 Nd IAFSS Eur Symp Fire Saf Sci, 2015.
58. HM Government, Approved Document L – Conservation of fuel and power n.d. (accessed February 1, 2015).