Axial load-bending moment diagrams of GFRP reinforced columns and GFRP encased square columns
Source abstract
Abstract
Abstract Fiber reinforced polymer (FRP) pultruded materials are available in a wide variety of shapes, including bars, I-sections, C-sections and other structural sections. Due to their high durability, low self-weight and reduced maintenance costs, these FRP materials are becoming a competitive option for replacing steel as structural materials especially in corrosive environments. This paper summarizes an experimental program on the axial and flexural behaviour of square concrete members reinforced with glass fiber reinforced polymer (GFRP) bars and embedded with pultruded GFRP structural sections under different loading conditions. Furthermore, an analytical model is presented to predict the axial load-bending moment interaction diagrams of the experimentally tested specimens. It can be concluded from this study that the analytical models provide reliable estimates of the maximum load and bending moment capacities of GFRP reinforced and GFRP encased concrete columns. In addition, a parametric study was conducted to study the effects of concrete compressive strength and longitudinal GFRP reinforcement ratio on the structural performance of GFRP reinforced square concrete columns.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. ACI 440.1R-15, Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer (FRP) Bars, American Concrete Institute, Farmington Hills, MI, 2015.
2. N. Kawaguchi, Ultimate Strength and Deformation Characteristics of Concrete Members Reinforced with AFRP Rods under Combined Axial Tension or Compression and Bending, Fiber-Reinforced-Plastic Reinforcement for Concrete Structures, SP-138, A, 1993.
3. Strength of rectangular concrete columns reinforced with fiber-reinforced polymer bars
4. Minimum reinforcement ratio for fiber-reinforced polymer reinforced concrete rectangular columns
5. Design of RC columns using glass FRP reinforcement10.1061/(ASCE)CC.1943-5614.0000354 ↗
6. M.N.S. Hadi, H. Karim, M.N. Sheikh, Experimental investigations on circular concrete columns reinforced with GFRP bars and helices under different loading conditions, J. Compos. Constr. 2015, http://dx.doi.org/10.1061/(ASCE)CC.1943-5614.0000670.10.1061/(ASCE)CC.1943-5614.0000670 ↗
7. Local buckling experiments on FRP columns10.1016/0263-8231(94)90012-4 ↗
8. Short-term behaviour and design of fiber-reinforced polymeric slender members under axial compression10.1061/(ASCE)1090-0268(1997)1:4(140) ↗
9. GFRP–concrete hybrid cross-sections for floors of buildings10.1016/j.engstruct.2008.04.021 ↗
10. Indicative performance of fiber reinforced polymer (FRP) encased beam in flexure10.1016/j.conbuildmat.2013.07.013 ↗
11. Experimental investigation of GFRP reinforced and GFRP encased square concrete specimens under axial and eccentric load, and four-point bending test10.1061/(ASCE)CC.1943-5614.0000675 ↗
12. AS1391-2007, Metallic materials – Tensile testing at ambient temperatures, Standards Australia, Sydney, Australia, 2007.
13. Pultrall, Inc., V-ROD – Specification HM, Thetford Mines, Canada, 2012, www.pultrall.com.
14. ASTM D7205-11, Standard test method for tensile properties of fiber reinforced polymer matrix composite bars, American Society for Testing and Materials, West Conshohocken, PA, USA, 2011.
15. GRP (Glass Reinforced Products), Load Test of Pultruded Sections – Report Data, Lytton, Queensland, Australia, 2008 (www.grpaustralia.com.au), accessed Aug. 08, 2014.
16. ISO. 527-4, Determination of tensile properties of plastics. Part 4: Test conditions for isotropic and orthotropic fiber-reinforced plastic composites, ISO, European Committee for Standardisation, Brussels, Belgium, 1997.
17. ASTM D695-15, Standard test method for compressive properties of rigid plastics, American Society for Testing and Materials, West Conshohocken, PA, 2015.
18. Experimental determination of the compressive strength of pultruded structural shapes10.1016/S0266-3538(99)00063-9 ↗
19. Stress-strain model for various unconfined concretes in compression
20. AS3600-2009, Concrete Structures, AS3600-2009, Standards Australia, Sydney, Australia, 2009.
21. Mallick · 1998 · 469
22. W.P. Wu, Thermomechanical properties of fiber reinforced plastic (FRP) Bars (Ph.D. dissertation), West Virginia University, Morgantown, WV 1990, 292 pp.
23. M.R. Ehsani, Glass-fiber reinforcing bars, alternative materials for the reinforcement and prestressing of concrete, in: J.L. Clarke (Ed.), Blackie Academic & Professional, London, UK, 1993, pp. 35–54.
24. Physical and mechanical performance of an innovative glass-fiber-reinforced plastic rod for concrete and grouted anchorage10.1139/l93-031 ↗
25. K. Kobayashi, T. Fujisaki, Compressive behaviour of FRP reinforcement in non-prestressed concrete members, in: 2nd International RILEM Symposium on Non-Metallic (FRP) Reinforcement for Concrete Structures, E & FN Spon, London, 1995, pp. 267–274.
26. Physical properties of glass fiber reinforced polymer rebars in compression10.1061/(ASCE)1090-0268(2003)7:4(363) ↗
27. ACI 318-14, Building code requirements for structural concrete, American Concrete Institute, Farmington Hills, MI, 2014.
28. CSA S806-12, Design and Construction of Building Structures with Fiber-Reinforced Polymers, Canadian Standards Association, Toronto, Canada, 2012.
29. Concrete columns reinforced longitudinally and transversally with glass fiber-reinforced polymer bars
30. Behaviour of concentrically loaded fiber-reinforced polymer reinforced concrete columns with varying reinforcement types and ratios
31. Axial load-bending moment diagrams of carbon FRP wrapped hollow core reinforced concrete columns10.1061/(ASCE)CC.1943-5614.0000010 ↗