Thermally-induced moisture transport in high-performance concrete studied by X-ray-CT and 1H-NMR
Source abstract
Abstract
Abstract The thermohydraulic damage mechanism is one of the primary causes for explosive spalling of high-performance concrete. This paper presents the spatially- and temporally-resolved analysis of the thermally-induced moisture transport and reconfiguration processes by means of X-ray-CT and 1 H-NMR. Thermal testing results for a high-performance concrete, which is sensitive to explosive spalling and which was prepared with and without added polypropylene fibres, are presented in this paper. These results indicate that the addition of fibres leads to a faster and deeper migration of the drying front and, thus, to a lower likelihood of vapour-pressure induced explosive spalling.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Engineering and Material Science Research · Geophysical Methods and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Planung unterirdischer Verkehrsanlagen gegen Brandgefahren
2. Jansson · 2007 · 735
3. Horvath · 2004
4. Spalling and pore pressure in HPC at high temperatures10.1016/S0008-8846(00)00384-7 ↗
5. Krusterle, W., et al., “Brandbeständigkeit von Faser-, Stahl- und Spannbeton”, Heft 544, 2004
6. Harmathy · 1965
7. Abplatzverhalten an Tunnelinnenschalenbeton10.1002/best.200200860 ↗
8. Jansson · 2009
9. One-dimensional scanning of moisture in heated porous building materials with NMR10.1016/j.jmr.2010.11.010 ↗
10. Neutron radiography of heated high-performance mortar10.1051/matecconf/20130603004 ↗
11. Real-time measurement of temperature, pressure and moisture profiles in High-Performance Concrete exposed to high temperatures during neutron radiography imaging10.1016/j.cemconres.2014.11.003 ↗
12. Stelzner · 2017 · 227
13. Water migration in one-side heated concrete: 4D In-Situ CT monitoring of the moisture-clog-effect10.1007/s10921-018-0552-7 ↗
14. Quantitative In-situ analysis of water transport in concrete completed using X-Ray computed tomography10.1007/s11242-018-1197-9 ↗
15. Dauti · 2017 · 249
16. Analysis of moisture migration in concrete at high temperature through in-situ neutron tomography10.1016/j.cemconres.2018.06.010 ↗
17. DIN EN 1992-1-2, “Eurocode 2: Bemessung und Konstruktion von Stahlbeton- und Spannbetontragwerken”, Teil 1-2: Allgemeine Regeln - Tragwerksbemessung für den Brandfall, Beuth Verlag GmbH, 2010.
18. “129-MHT Test Methods for mechanical properties of concrete at high temperatures”, Compressive strength for service and accident conditions, Volume 28, (7), 1995.
19. Three-Dimensional X-Ray Microtomography10.1126/science.237.4821.1439 ↗
20. Practical cone-beam algorithm10.1364/JOSAA.1.000612 ↗
21. Blümich · 2014
22. Modified spin-echo method for measuring nuclear relaxation times10.1063/1.1716296 ↗
23. Observation of the redistribution of nanoscale water filled porosity in cement based materials during wetting10.1016/j.cemconres.2014.10.013 ↗
24. Localization and identification of thin oil layers using a slim-borehole nuclear magnetic resonance tool
25. Three-dimensional modelling and inversion of dc resistivity data incorporating topography – II. Inversion10.1111/j.1365-246X.2006.03011.x ↗
26. Artefacts in CBCT: a review10.1259/dmfr/30642039 ↗
27. A study of reconstruction artifacts in cone beam tomography using filtered backprojection and iterative EM algorithms10.1109/23.106711 ↗
28. Permeability measurement on high strength concrete without and with polypropylene fibers at elevated temperatures using a new test setup10.1016/j.cemconres.2013.06.005 ↗
29. Harvey · 2014