Accelerated electric curing of steel-fibre reinforced concrete
Source abstract
Abstract
This paper evaluates the effect of electric curing on the mechanical properties and microstructure of steel fibre reinforced concrete. Specimens subjected to electric curing, steam curing and without curing were tested for compressive and residual flexural tensile strengths at different ages. The fibre-matrix contact area after pull-out was characterized by means of scanning electron microscopy. Although electric cured specimens had consistently smaller residual flexural strengths than steam cured specimens, differences were not statistically significant. Results derived from this study confirm the feasibility of applying electric curing for the production of elements made with steel-fibre reinforced concrete.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Innovative concrete reinforcement materials · Fire effects on concrete materials · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Taylor · 2013
2. Various methods of accelerated curing for precast concrete applications, and their impact on short and long term compressive strength
3. Electrical curing of concrete10.1680/macr.1959.1.1.21 ↗
4. Direct electric curing of concrete: basic design
5. Microwave curing technique in concrete manufacture10.1016/0008-8846(87)90103-7 ↗
6. Fibre reinforced cement-based (FRC) composites after over 40 years of development in building and civil engineering10.1016/j.compstruct.2008.03.006 ↗
7. Structural behaviour of precast tunnel segments in fiber reinforced concrete10.1016/j.tust.2010.10.003 ↗
8. Experiences in Barcelona with the use of fibres in segmental linings10.1016/j.tust.2011.07.001 ↗
9. Paillere, A., Serrano, J. (1981). Utilisation de la conductivité des fibres métalliques dans le traitement thermique des bétons frais. Bull. Liason Labo. P. et Ch.113:59-61 (in French)
10. EN 14651 (2005). Test method for metallic fibre concrete - measuring the flexural tensile strength (limit of proportionality (LOP), residual)
11. Assessment of fibre content and 3D profile in cylindrical SFRC specimens10.1617/s11527-014-0521-2 ↗
12. Improved assessment of fibre content and orientation with inductive method in SFRC10.1617/s11527-014-0279-6 ↗
13. Inductive method for assessing the amount and orientation of steel fibers in concrete10.1617/s11527-012-9858-6 ↗
14. EN 12390-3, Testing Hardened Concrete. Part 3: Compressive Strength of Test Specimens, 2003.
15. UNE 83515, Hormigones con fibras. Determinación de la resistencia a fisuración, tenacidad y resistencia residual a tracción (Fibre reinforced concrete. Determination of cracking strength, ductility and residual tensile strength), 2010.
16. Generalization of the Barcelona test for the toughness control of FRC10.1617/s11527-011-9816-8 ↗
17. New analytical model to generalize the Barcelona test using axial displacement10.3846/13923730.2012.756425 ↗
18. Multidirectional double punch test to assess the post-cracking behaviour and fibre orientation of FRC10.1016/j.conbuildmat.2014.02.023 ↗
19. Upcrete® and SCC – a new production method for precast elements to meet highest demands
20. Beyond the floor cycle: integral casting of walls and floor slabs through double shutter formwork and SCC
21. Krylov · 1997
22. Direct electric curing of concrete10.1680/macr.1993.45.162.71 ↗
23. Equipment for the investigation of the accelerated curing of concrete using direct electrical conduction10.1016/j.measurement.2003.11.002 ↗
24. Thermal acceleration of Portland cement concretes using direct electronic curing
25. Direct electric curing of in situ concrete
26. The conduction of electricity through concrete10.1680/macr.1981.33.114.48 ↗
27. Electrical resistivity of concrete-a literature review
28. Preliminary interpretation of Portland cement hydration process using resistivity measurements
29. Self-compacting concrete: an analysis of 11 years of case studies10.1016/j.cemconcomp.2005.10.003 ↗
30. A method for mix-design of fiber-reinforced self-compacting concrete10.1016/j.cemconres.2007.03.014 ↗
31. Reinforcing the future
32. Intrinsic scatter of FRC: an alternative philosophy to estimate characteristic values10.1617/s11527-014-0420-6 ↗
33. Setting time: an important criterion to determine the length of the delay period before steam curing of concrete10.1016/S0008-8846(02)01058-X ↗
34. Short-term steam-curing and concrete later-age strength10.1007/BF02478955 ↗
35. Correlation between the Barcelona test and the bending test in fibre reinforced concrete10.1016/j.conbuildmat.2017.07.028 ↗
36. Framework to predict the orientation of fibers in FRC: a novel philosophy10.1016/j.cemconres.2012.02.013 ↗
37. Comparison of methods for arresting hydration of cement10.1016/j.cemconres.2011.06.003 ↗
38. Effect of steam curing on class C high-volume fly ash concrete mixtures10.1016/j.cemconres.2004.08.011 ↗
39. Mehta · 2006
40. Effects of transition zone densification on fiber/cement paste bond strength improvement10.1016/S1065-7355(97)90010-9 ↗
41. The alternating current electrolysis of water10.1139/cjr29-020 ↗
42. The microstructure of the steel fibre-cement interface10.1007/BF01113768 ↗