journal article·2020-01

Performance of polypropylene fiber reinforced concrete-filled UPVC tube columns under axial compression

Shahram Mohammad Askari, Alireza Khaloo, Mohammad Hadi Borhani, Mohammad Sadegh Tale Masoule

Publisher page

Abstract

Abstract This paper aims to study the behavior of UPVC-confined columns reinforced with polypropylene fibers under axial compression. A sum of 42 column specimens has been tested, including 18 Unconfined Concrete Cylinders (UCC) and 24 confined Concrete-Filled UPVC Tube (CFUT) specimens. To investigate the sensitivity of these columns to various parameters, different levels of material volumes have been used, which include two concrete strengths of 40 and 50 MPa, two tube grades of PN6 and PN10, and three polypropylene fiber content of 0, 1 and 3 kg/m3 of the concrete mixture. The influence of each variable on the ultimate strength, ductility and confinement effectiveness of the specimens have been examined. Similar test data on the PVC-confined specimens have been collected from the literature, and along with the test data of the current study, are used to determine the influence of various parameters on the response of composite columns. Finally, a model for the prediction of ultimate strength of PVC composite columns is proposed using two different coefficients: one for UPVC tube and one for confined concrete. The confined concrete coefficient is calculated from the database by considering numerous regression models that showed strong dependency to column diameter to pipe thickness ratio (D/t), UPVC pipe tensile yield stress to concrete compressive strength ratio (fy/fc′) and the fiber content. It was found that polypropylene fibers slightly increase the column strength up to a certain volume fraction, after which strength usually experiences a decline. Ductility, on the other hand, increases considerably with fiber volume fraction. UPVC tubes have a positive effect on both ultimate load-bearing capacity and especially ductility of the column. Though not as strong as their steel counterparts, they present certain benefits such as low cost and environmental resistance that can be a determining factor in certain practices.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Behavior of steel fiber reinforced concrete-filled steel tube columns under axial compression10.1016/j.conbuildmat.2015.07.114 ↗
2. Strength, stiffness and ductility of concrete-filled steel columns under axial compression10.1016/j.engstruct.2016.12.049 ↗
3. Concrete filled PVC tube: A review10.1016/j.conbuildmat.2017.08.156 ↗
4. Investigation on compressive behaviors of thermoplastic pipe confined concrete10.1016/j.conbuildmat.2012.04.017 ↗
5. Performance of UPVC Pipe Confined Concrete Columns in Compression, Jomo Kenyatta University of Agriculture and
6. Saadon · 2010
7. Study of concrete-filled unplasticized poly-vinyl chloride tubes in marine environment
8. Durability studies on concrete columns encased in PVC–FRP composite tubes10.1016/S0263-8223(01)00067-8 ↗
9. Effect of fiber on the concrete resistance to surface scaling due to cyclic freezing and thawing10.1016/j.proeng.2015.07.065 ↗
10. A.A. Havez, N. Wahab, A. Al-Mayah, K.A. Soudki, Behaviour of PVC encased reinforced concrete walls under eccentric axial loading, in: Structures, Elsevier, 2016: pp. 67–75.10.1016/j.istruc.2015.09.003 ↗
11. Experimental study and theoretical analysis on slender concrete-filled CFRP–PVC tubular columns10.1016/j.conbuildmat.2013.11.089 ↗
12. Compressive behavior of FRP-confined concrete-filled PVC tubular columns10.1016/j.compstruct.2016.01.004 ↗
13. FRP-confined concrete filled PVC tubes: A new design concept for ductile column construction in seismic regions10.1016/j.conbuildmat.2016.11.056 ↗
14. Effect of intumescent paint coating on mechanical properties of FRP bars at elevated temperature10.1016/j.polymertesting.2018.08.020 ↗
15. Experimental investigation and probabilistic models for residual mechanical properties of GFRP pultruded profiles exposed to elevated temperatures10.1016/j.compstruct.2018.12.032 ↗
16. Experimental study on PVC-CFRP confined concrete columns under low cyclic loading10.1016/j.conbuildmat.2018.05.111 ↗
17. Strength and ductility improvement of recycled aggregate concrete by polyester FRP-PVC tube confinement10.1016/j.compositesb.2018.10.102 ↗
18. Experimental study on steel tubular columns in-filled with plain and steel fiber reinforced concrete10.1016/j.tws.2010.01.009 ↗
19. Mechanical properties of polypropylene fiber reinforced concrete and the effects of pozzolanic materials10.1016/0958-9465(95)00003-8 ↗
20. Mechanical properties of polypropylene hybrid fiber-reinforced concrete10.1016/j.msea.2008.05.037 ↗
21. Microscopic, physical and mechanical analysis of polypropylene fiber reinforced concrete10.1016/j.msea.2009.07.056 ↗
22. 4. Design of steel and concrete structures, Part1.1, General rules and rules for building
23. Tests on stub columns of concrete-filled RHS sections10.1016/S0143-974X(01)00059-1 ↗
24. Fire performance of concrete filled steel tubular beam-columns10.1016/S0143-974X(00)00030-4 ↗
25. Experimental behaviour of stiffened concrete-filled thin-walled hollow steel structural (HSS) stub columns10.1016/j.jcsr.2004.12.003 ↗
26. A study of the failure of concrete under combined compressive stresses, University of Illinois at Urbana
27. Failure of plain and spirally reinforced concrete in compression, University of Illinois at Urbana