journal article·2011-04

Mechanical investigation of two fiber-reinforced repair mortars and the repaired system

Amjad Mallat, Abdenour Alliche

Publisher page

Abstract

Abstract The mechanical behavior of two repair mortars was investigated. The first one is a fiber reinforced lime-based mortar, which contains thickening agent and limestone additions. The second one is a fiber reinforced ordinary mortar, which contains a small quantity of silica fume and additives. Mechanical characterization was based on compression, tensile and three-point bending tests. The bond between the repair mortars and substrate was investigated by slant shear and flexural bonding tests. The results obtained have demonstrated the influence of the surface roughness and moisture conditions on the bond strength. Finally, Scanning Electron Microscopic observations have showed the morphology of the repair mortar-to-substrate interfacial zone.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Innovative concrete reinforcement materials · Concrete and Cement Materials Research · Building materials and conservation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Repair material properties for effective structural application10.1016/S0008-8846(97)00027-6 ↗
2. Mechanical behaviour of polymer modified mortars10.1016/j.msea.2004.03.049 ↗
3. Pascal S. Comportement mécanique de composites mortier polymère, Ph.D. Thesis, Ecole Centrale Paris, Châtenay-Malabry, France; 2002.
4. Repair of concrete floors with polymer modified cement mortars
5. Transition zone studies of new-to-old concrete with different binders10.1016/S0958-9465(01)00002-6 ↗
6. Concrete-to-concrete bond strength. influence of the roughness of the substrate surface10.1016/j.conbuildmat.2004.04.023 ↗
7. Surface repair, section 6: bonding repair materials to existing concrete
8. AFNOR, EN 12617-4: determination of shrinkage and expansion, AFNOR, France; 2002.
9. Mallat A, Alliche A. Physico-chemical and mechanical behaviors of fiber reinforced repair mortars. Third international conference on FRP composites in civil engineering (CICE 2006), Miami, USA; 2006. p. 511–4 [part 18].
10. Mallat A. Phénomènes de dégradation des ouvrages anciens, techniques et matériaux de réhabilitation, Ph.D. Thesis, École Centrale Paris, Châtenay-Malabry, France; 2008.
11. Mallat A, Alliche A. A modified tensile test to study the behaviour of cementitious materials, Strain, doi: 10.1111/j.1475-1305.2009.00717.x.10.1111/j.1475-1305.2009.00717.x ↗
12. Arizona slant shear test
13. The evaluation of resin systems for concrete repair10.1680/macr.1978.30.105.221 ↗
14. BSI, BS 6319: part 4 slant shear test method for evaluating bond strength of epoxy systems. London: BSI British Standards; 1984.
15. ASTM, C882-99 standard test method for bond strength of epoxy-resin systems used with concrete by slant shear. American Society for Testing and Materials.
16. Factors affecting bond between new and old concrete
17. The dimensioning of adhesive-bonded joints in concrete building components
18. Evaluation of bond strength between old and new concrete
19. Evaluation of test methods for measuring the bond strength of portland cement based repair material to concrete10.1520/CCA10096J ↗
20. A unified failure envelope from the evaluation of concrete repair bond tests10.1680/macr.1995.47.170.57 ↗
21. Miltiadou AE. Étude des coulis hydrauliques pour la répartition et le renforcement des structures et des monuments historiques en maçonnerie, Ouvrages dart OA8, Laboratoire Central des ponts et Chaussées, France; 1991.
22. Significance of property mismatch in the patch repair of structural concrete. part 1: properties of repair systems10.1680/macr.1990.42.152.147 ↗
23. Folliot A, Buil M. La structuration progressive de la pierre de ciment, in: Le béton hydraulique: connaissance et pratique, Presses de l’ENPC, Paris; 1982.