Monitoring moisture movements in building materials using X-ray attenuation: Influence of beam-hardening of polychromatic X-ray photon beams
Source abstract
Abstract
X-ray attenuation measurements are commonly used as a non-destructive method to monitor internal concentration changes of moisture (i.e., moisture content) and other chemical compounds in porous building materials. The technique provides direct measurements of moisture content changes through analysis with a composite model consisting of a dry porous material and a thickness of water equivalent to the moisture content of the material. The current formulation of this composite model relies on certain assumptions, including a monochromatic X-ray photon beam source (i.e., X-ray photons of a single, consistent energy) and that interactions between the X-ray photons and the materials (water and porous material) are independent. However, X-ray sources typically used by researchers in this field of study produce X-ray photon beams over a spectrum of energy levels, or polychromatic X-ray photons. Implications of this inconsistency are introduced and discussed. This paper presents both an overview of fundamental descriptions of the X-ray attenuation measurement technique and results from a parametric experimental study of various porous construction materials, including calcium silicate board, aerated autoclaved concrete, clay brick, cementitious materials, and wood. Results from the parametric investigation indicate the attenuation coefficient of water is dependent on the type and thickness of the porous material.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Geophysical Methods and Applications · Ultrasonics and Acoustic Wave Propagation · Concrete and Cement Materials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Timber-framed partition walls and their restraining effect on warp in built-in wall studs – models for twist10.1016/j.conbuildmat.2009.06.048 ↗
2. Measuring the water capacity and transfer properties of fresh mortar10.1016/j.cemconres.2010.08.002 ↗
3. Influence of shrinkage-reducing admixtures on the development of plastic shrinkage cracks
4. Environmental cycling and laboratory testing to evaluate the significance of moisture control for lime mortars10.1016/j.conbuildmat.2010.01.019 ↗
5. Evaluation of moisture susceptibility of porous asphalt concrete using water submersion fatigue tests10.1016/j.conbuildmat.2009.08.016 ↗
6. Influences of mixture composition on properties and freeze-thaw resistance of rcc10.1016/j.conbuildmat.2010.06.023 ↗
7. A comparison of different techniques to quantify moisture content profiles in porous building materials
8. Hansen K, Jensen S, Gerward L, Singh K. Dual-energy X-ray absorptiometry for the simultaneous determination of density and moisture content in porous structural materials. In: Proceedings of the 5th symposium on building physics in the Nordic countries, vol. 1. Gothenburg, Sweden; 1999. p. 281–8.
9. Shrinkage-reducing admixtures and early-age desiccation in cement pastes and mortars10.1016/S0008-8846(01)00519-1 ↗
10. X-ray absorption study of drying cement paste and mortar10.1016/S0008-8846(02)00972-9 ↗
11. Direct measurement of the soil water retention curve using X-ray absorption10.5194/hess-8-2-2004 ↗
12. Measuring moisture content profiles in a board during drying: a polychromatic X-ray system interfaced with a vacuum/pressure laboratory kiln10.1007/s00226-006-0068-7 ↗
13. Measurement of water transport from saturated pumice aggregates to hardening cement paste10.1617/s11527-006-9137-5 ↗
14. Analysis of moisture flow in porous materials using microfocus X-ray radiography10.1016/j.ijheatmasstransfer.2006.06.035 ↗
15. The application of X-ray absorption to building moisture transport studies10.1016/j.measurement.2006.10.016 ↗
16. Pease B, Couch J, Geiker M, Stang H, Weiss J. Assessing the portion of the crack length contributing to water sorption using X-ray absorption measurements on concrete wedge splitting specimens. In: ConcreteLife’09: second international RILEM workshop on concrete durability and service life planning, Haifa, Israel; 2009.
17. Pour-Ghaz M, Rajabipour F, Couch J, Weiss J. Modeling fluid transport in cementitious systems with crack-like (notch) geometries. In: ConcreteLife’09: second international RILEM workshop on concrete durability and service life planning; 2009.
18. Using X-ray absorption to assess moisture movement in cement-based materials10.1520/JAI102234 ↗
19. The testing of two methods for the moisture measurement of building fabrics via comparisons with data from an X-ray system10.1016/j.buildenv.2008.04.009 ↗
20. Pease B. Influence of concrete cracking on ingress and reinforcement corrosion, Ph.D. thesis, Technical University of Denmark, Kgs. Lyngby, Denmark; December 2010.
21. Measuring and simulating moisture uptake in a fractured porous medium10.1016/S0309-1708(02)00185-9 ↗
22. Three-dimensional liquid transport in concrete cracks10.1002/nag.373 ↗
23. Monitoring reinforcement corrosion and corrosion-induced cracking using non-destructive X-ray attenuation measurements10.1016/j.cemconres.2011.06.006 ↗
24. Knoll · 1989
25. Tsoulfanidis · 1983
26. Van Geet M. Optimisation of microfocus X-ray computer tomography for geological reserach with special emphasis on coal components (macerals) and fractures (cleats) characterisation, Ph.D. thesis, KU Leuven, Heverlee; April 2001.
27. Dyson · 1973
28. Curry · 1990
29. Hubbell J, Seltzer S. Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients. Tech Rep NISTIR 5632. National Institute of Standards and Technology, Maryland, USA; 2004.
30. Beam hardening in X-ray reconstructive tomography10.1088/0031-9155/21/3/004 ↗
31. Weiss J, Geiker M, Hansen K. Using X-ray absorption to detect fluid ingress in cracked concrete. Tech rep. Purdue University School of Civil Engineering, West Lafayette, IN, USA; 2004. p. 15.
32. Analytical considerations of beam hardening in medical accelerator photon spectra10.1118/1.598704 ↗
33. Beam hardening: analytical considerations of the effective attenuation coefficient of X-ray tomography10.1118/1.2742501 ↗
34. GNI X-ray System. Technical University of Denmark; 2010. .
35. A CdTe real time X-ray imaging sensor and system10.1016/j.nima.2004.02.046 ↗
36. A photon counting CdTe gamma- and X-ray camera10.1016/j.nima.2005.04.081 ↗