journal article·2018-06Open access

Effects of rising damp and salt crystallization cycles in FRCM-masonry interfacial debonding: Towards an accelerated laboratory test method

Elisa Franzoni, Cristina Gentilini, Mattia Santandrea, Christian Carloni

Abstract

Abstract Fiber-reinforced composites with inorganic matrix (FRCMs) have been recently proposed as a more compatible and durable route to strengthen masonry structures with respect to FRPs (fiber-reinforced polymers), but their weathering mechanisms in aggressive environments are still scarcely known. In this paper, brick masonry specimens were reinforced with FRCM strips, made of galvanized steel fibers embedded within a hydraulic lime-based mortar, and were subjected to an artificial weathering procedure designed by the authors, involving capillary water absorption and salt crystallization cycles. Finally, direct shear tests were performed on the FRCM-masonry joints. To reproduce conditions that may be found in real buildings, shear tests were also carried out after applying the FRCM composite on salt laden masonry blocks. Interfacial debonding behavior was interpreted based on the salt distribution within the masonry joints and the porosity of materials. The permeable matrix did not hinder the migration of the saline solution used in some cycles, which in turn resulted in no significant accumulation of salts beneath the composite strip, and no micro-crack opening in the composite after accelerated weathering. Some corrosion of the galvanized steel cords in presence of high amount of chlorides was observed in the composite.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Building materials and conservation · Masonry and Concrete Structural Analysis · Concrete and Cement Materials Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. Seismic vulnerability assessment of a historical church: limit analysis and nonlinear finite element analysis10.1155/2013/517454 ↗
2. Multi-directional seismic assessment of historical masonry buildings by means of macro-element modelling: application to a building damaged during the L'Aquila earthquake (Italy)10.3390/buildings7040106 ↗
3. Damage patterns in the town of Amatrice after August 24th 2016 Central Italy earthquakes10.1007/s10518-017-0254-z ↗
4. Seismic-induced damage in historical masonry vaults: a case-study in the 2012 Emilia earthquake-stricken area10.1016/j.jobe.2017.08.005 ↗
5. Damage assessment of three medieval churches after the 2012 Emilia earthquake10.1007/s10518-016-0073-7 ↗
6. Current practice and open issues in strengthening historical buildings with composites10.1617/s11527-014-0359-7 ↗
7. The role of mortar joints in FRP debonding from masonry10.1016/j.compositesb.2017.10.021 ↗
8. Debonding process of masonry element strengthened with FRP10.1016/j.proeng.2015.06.206 ↗
9. Bond behaviour of FRP strips glued on masonry: experimental investigation and empirical formulation10.1016/j.conbuildmat.2011.12.100 ↗
10. FRP–brick masonry bond degradation under hygrothermal conditions10.1016/j.compstruct.2016.03.037 ↗
11. Effect of environmental aging on the numerical response of FRP-strengthened masonry walls10.1061/(ASCE)ST.1943-541X.0001358 ↗
12. Influence of water on bond behavior between CFRP sheet and natural calcareous stones10.1016/j.compositesb.2012.03.002 ↗
13. Out-of-plane behavior of URM walls strengthened with fabric-reinforced cementitious matrix composite
14. Textile reinforced mortar (TRM) versus FRP as strengthening material of URM walls: out-of-plane cyclic loading
15. A. Mordanova, S. De Santis, G. De Felice. State-of-the-art review of out-of-plane strengthening of masonry walls with mortar-based composites (2016) Structural Analysis of Historical Constructions: Anamnesis, diagnosis, therapy, controls – in: Proceedings of the 10th International Conference on Structural Analysis of Historical Constructions, SAHC 2016, 337–343.10.1201/9781315616995-44 ↗
16. Rising damp removal from historical masonries: a still open challenge10.1016/j.conbuildmat.2013.12.054 ↗
17. Repair systems for the restoration of ancient buildings – dampness rise problem10.1515/rbm-2007-6129 ↗
18. E. Garavaglia, C. Tedeschi, S. Perego, M.R. Valluzzi, Probabilistic modelling of the damage induced by salt crystallization in fiber reinforced clay brick masonry (2016) Brick and Block Masonry: Trends, Innovations and Challenges – in: Proceedings of the 16th International Brick and Block Masonry Conference, IBMAC 2016, 487–494.10.1201/b21889-59 ↗
19. Influence of salt crystallization on composites-to-masonry bond evaluated on site by pull-off tests10.4028/www.scientific.net/KEM.624.338 ↗
20. D. Arboleda, S. Babaeidarabad, C. DiLaurenzio Hays, A. Nanni, Durability of Fabric Reinforced Cementitious Matrix (FRCM) composites (2014) in: Proceedings of the 7th International Conference on FRP Composites in Civil Engineering, CICE.
21. Fabric-reinforced cementitious matrix behavior at high-temperature: experimental and numerical results10.1016/j.compositesb.2016.10.004 ↗
22. Salt weathering: a selective review10.1144/GSL.SP.2002.205.01.05 ↗
23. Salts in the deterioration of porous materials: an overview10.1179/019713600806113176 ↗
24. Durability of steel FRCM-masonry joints: effect of water and salt crystallization10.1617/s11527-017-1070-2 ↗
25. EN 772–1 Methods of test for masonry units – Part 1: Determination of compressive strength, 2015.
26. EN 998-2 Specification for mortar for masonry – Part 2: Masonry mortar, 2016.
27. Kerakoll 2017. Technical data sheet Biocalce Muratura. http://products.kerakoll.com/gestione /immagini/prodotti/00339bio%20muratura%202013.pdf.
28. EN 1015–11 Methods of test for mortar for masonry - Part 11: Determination of flexural and compressive strength of hardened mortar, 1999.
29. Kerakoll 2016. Technical data sheet GeoSteel G600. http://products.kerakoll.com/gestione /immagini/prodotti/00075GeoSteel%20G600%202016.pdf.
30. Effect of salt crystallisation on the shear behaviour of masonry walls: an experimental study10.1016/j.conbuildmat.2012.07.086 ↗
31. Towards the assessment of the shear behaviour of masonry in on-site conditions: a study on dry and salt/water conditioned brick masonry triplets10.1016/j.conbuildmat.2014.05.002 ↗
32. EN 12370 Natural stone test methods – Determination of resistance to salt crystallization, 1999.
33. Determination of the resistance of wallettes against sulphates and chlorides10.1007/BF02486406 ↗
34. Unidirectional salt crystallization test for masonry units10.1007/BF02486407 ↗
35. Materials decay and environmental attack in the Pio Palace at Carpi: a holistic approach for historical architectural surfaces conservation10.1016/j.buildenv.2006.04.021 ↗
36. Characterization procedure for ancient mortars’ restoration: the plasters of the Cavallerizza courtyard in the Ducal Palace in Mantua (Italy)10.1016/j.matchar.2009.10.012 ↗
37. Rising moisture, salts and electrokinetic effects in ancient masonries: from laboratory testing to on-site monitoring10.1016/j.culher.2013.03.003 ↗
38. Compressive behaviour of brick masonry triplets in wet and dry conditions10.1016/j.conbuildmat.2015.02.052 ↗
39. Multi-scale analysis on the influence of moisture on the mechanical behavior of ferruginous sandstone10.1016/j.conbuildmat.2013.12.024 ↗
40. An investigation of the debonding mechanism between FRCM composites and a masonry substrate10.4028/www.scientific.net/KEM.747.382 ↗
41. Experimental analysis of the bond behavior of glass, carbon, and steel FRCM composites10.4028/www.scientific.net/KEM.624.371 ↗
42. Role of the matrix layers in the stress-transfer mechanism of FRCM composites bonded to a concrete substrate
43. Effect of the inherent eccentricity in single-lap direct-shear tests of PBO FRCM-concrete joints10.1016/j.compstruct.2016.01.076 ↗
44. Matrix-fiber bond behavior in PBO FRCM composites: a fracture mechanics approach10.1016/j.engfracmech.2014.01.011 ↗
45. Problems connected with use of hot-dip galvanized reinforcement in concrete elements10.1016/j.proeng.2017.02.086 ↗
46. Corrosion characteristics in concrete environment of hot dip galvanised steel and Zn alloy hot dip coated steel10.1179/174591908X371177 ↗
47. Bellezze T, Fratesi R, Tittarelli F. Corrosion behaviour of galvanized steel rebars in the presence of coating discontinuities (2006) Corrosion of Reinforcement in Concrete: Monitoring, Prevention and Rehabilitation Techniques, 27–37.10.1533/9781845692285.27 ↗
48. Corrosion resistance of galvanized steel reinforcements in carbonated concrete: effect of wet–dry cycles in tap water and in chloride solution on the passivating layer10.1016/j.cemconres.2014.07.014 ↗
49. Effect of inhibitors on the corrosion of galvanized steel and on mortar properties10.1016/j.cemconcomp.2012.08.014 ↗
50. Degradation mechanism of galvanized steel in wet–dry cyclic environment containing chloride ions10.1016/S0010-938X(03)00153-7 ↗
51. Atmospheric corrosion of galvanised steel in different environments in Chile and Mexico10.1016/S1452-3981(23)11071-6 ↗