Strength of compression lap-spliced GFRP bars in concrete columns with different splice lengths
Source abstract
Abstract
Abstract Recent years have seen valuable research work on using glass-fiber-reinforced-polymer (GFRP) bars in reinforced-concrete (RC) members under compression. Nonetheless, lap splicing of GFRP bars under compression has not yet been explored with due consideration of its components. To address this knowledge gap, this paper comparatively demonstrates the results of an experimental investigation pertaining to the effect of splice length on the compression lap splicing of GFRP bars in concrete columns. The experiment comprised 11 large-scale circular columns measuring 300 mm in diameter and 1600 mm in height: seven specimens reinforced with GFRP bars, three specimens with steel bars for comparison purposes, and one specimen without reinforcement (plain concrete). All columns were tested under a monotonically increasing concentric load. The test variables included the reinforcement type (GFRP versus steel) and splice length. The results were compared in terms of the stress–strain curves, ultimate loading, displacement capacity, and splice strength. The test results indicate that the required compression splice length for GFRP bars is less than that required for steel. As the strength of a compression splice consists of end-bearing and bond components, the contribution of each part was scrutinized in detail using measured strain values. The required splice length for GFRP bars was considerably based on the end-bearing component. Based on the experimental results, a length of 8 d b can reliably be considered as the required splice length for No. 5 GFRP bars in compression.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. ACI Committee 440. Guide for the Design and Construction of Structural Concrete Reinforced with FRP Bars (ACI 440.1R-15). Farmington Hills, MI: American Concrete Institute, 2015.
2. Flexural stiffness and second-order effects in fiber-reinforced polymer-reinforced concrete frames10.14359/51689257 ↗
3. Shear strength of FRP reinforced concrete members with stirrups10.1061/(ASCE)CC.1943-5614.0000483 ↗
4. Shear capacity of RC and PC beams using FRP reinforcement
5. Shear resistance of FRP RC beams: experimental study10.1061/(ASCE)1090-0268(2006)10:6(464) ↗
6. Shear behavior of circular concrete members reinforced with GFRP bars and spirals at shear span-to-depth ratios between 1.5 and 3.0
7. Shear strength of large concrete members with FRP reinforcement10.1061/(ASCE)CC.1943-5614.0000108 ↗
8. Brhaviour of restrained concrete bridge deck slabs reinforced with FRP reinforcing bars under concentrated loads, El-Gamal.pdf
9. Shear strength of fibre-reinforced polymer reinforced concrete deep beams without web reinforcement10.1139/l2012-034 ↗
10. Shear behavior of large reinforced concrete beams without web reinforcement10.1061/(ASCE)CC.1943-5614.0000385 ↗
11. Punching shear strength of flat slabs reinforced with glass fibre-reinforced polymer (GFRP) bars
12. Design of RC columns using glass FRP reinforcement10.1061/(ASCE)CC.1943-5614.0000354 ↗
13. Design and performance of reinforced concrete water chlorination tank totally reinforced with GFRP bars: case study10.1061/(ASCE)CC.1943-5614.0000429 ↗
14. Behavior of full-scale glass fiber-reinforced polymer reinforced concrete columns under axial load
15. Behavior of concentrically loaded fiber-reinforced polymer reinforced concrete columns with varying reinforcement types and ratios10.14359/51686630 ↗
16. Axial capacity of circular concrete columns reinforced with GFRP bars and spirals
17. Confinement model for concrete columns internally confined with carbon FRP spirals and hoops10.1061/(ASCE)ST.1943-541X.0001197 ↗
18. Experimental investigations on circular concrete columns reinforced with GFRP bars and helices under different loading conditions10.1061/(ASCE)CC.1943-5614.0000670 ↗
19. Failure envelope of circular concrete columns reinforced with glass fiber-reinforced polymer bars and spirals10.14359/51689498 ↗
20. Experimental study of circular high-strength concrete columns reinforced with GFRP bars and spirals under concentric and eccentric loading
21. Axial load-moment interaction diagram of circular concrete columns reinforced with CFRP bars and spirals: experimental and theoretical investigations
22. CAN/CSA S806-12. Design and construction of building structures with fiber reinforced polymers. Mississauga, Ontario, Canada: Canadian Standards Association, 2012.
23. High strength bars as concrete reinforcement, Part 5: lap splices in concentrically loaded columns
24. ACI Committee 318. Building code Requirements for Structural Concrete (ACI 318M-14) and Commentary (ACI318RM-14). Farmington Hills, MI: American Concrete Institute, 2014.
25. Compression lap splice in unconfined concrete of 40 and 60 MPa (5800 and 8700 psi) compressive strengths
26. CSA A23.3-14. Design of concrete structures. Mississauga, Ontario, Canada: Canadian Standards Association, 2014.
27. ASTM. Standard Test Method for Tensile Properties of Fiber Reinforced Polymer Matrix. vol. i. West Conshohocken, PA: ASTM D7205M-06, 2011.
28. Strength of compression splices a reevalution of test data
29. Simplified design equation of lap splice length in compression10.4334/IJCSM.2010.4.1.063 ↗
30. Park · 1974
31. Compression splices in confined concrete of 40 and 60 MPa (5800 and 8700 psi) compressive strengths
32. Behaviour of contact and noncontact lap compression splices
33. Fracture of plain concrete under biaxial stresses10.1016/0008-8846(74)90031-3 ↗
34. Behavior of concrete under biaxial stresses
35. A study of the failure of concrete under combined compressive stresses
36. ACI Committee 408. Bond and Development of Straight Reinforcing Bars in Tension (ACI 408-03). Farmington Hills, MI: American Concrete Institute, 2003.
37. Bond strength of lap-spliced bars
38. Bond strength of high relative rib area reinforcing bars
39. Bond strength of high relative rib area reinforcing bars
40. Splice strength of conventional and high relative rib area bars in normal and high-strength concrete
41. Comparison of bond strength of steel bars in normal- and high-strength concrete10.1061/(ASCE)0899-1561(2004)16:4(365) ↗
42. Lateral blow-out failure of headed studs near a free edge
43. CAN/CSA S6-14. Canadian Highway Bridge Design code. Mississauga, Ontario, Canada: Canadian Standards Association, 2014.
44. Concrete columns reinforced longitudinally and transversally with glass fiber-reinforced polymer bars
45. Components of compression splice resistances in high-strength concrete10.1680/jmacr.16.00412 ↗
46. Strength of lapped splices in reinforced concrete columns
47. Bond strength and Load distribution of composites GFRP reinforcing bars in concrete