journal article·2001-03

Near–surface sensors for condition monitoring of cover-zone concrete

W.J McCarter, T.M Chrisp, A Butler, P.A.M Basheer

Construction and Building Materials· Volume 15· Issue 2-3
Publisher page

Abstract

Abstract With more demands being made on reinforced concrete, 100-year guarantees of durability will become a necessity. Lifetime calculations, and prediction of the residual service-life of structures, require quantitative information on cover-zone properties and threshold values for corrosion initiation. It is clear that there exists a need to determine quantitatively those near-surface characteristics of concrete which promote the ingress of gases and/or liquids containing dissolved contaminants. In addition, in-situ monitoring of the temporal change in such properties could assist in making realistic predictions as to the in-service performance of the structure; likely deterioration rates for a particular exposure condition or compliance with the specified design life. This paper details covercrete sensor arrangements; format of data presentation and information that can be obtained from embedded sensors. Such sensors could, ultimately, form part of a high-level monitoring strategy and should be considered at the design stage.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Analytical Chemistry and Sensors · Smart Materials for Construction

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. European Committee for Standardisation (CEN), Eurocode 1: Basis of design and actions on structures, Part 1: Basis of Design. CEN, Brussels, ENV 1991;1:1994.
2. Eurocode 2-innovations in design and construction of concrete structures
3. European Committee for Standardisation (CEN), Concrete Performance, Production and Conformity. Draft CEN. Brussels, prEN 206, 1997.
4. Schießl, P., Raupach, M., Instrumentation of structures with sensors-why and how? In: R.K. Dhir, M.R. Jones editor. Proceedings of the Concrete in the Service of Mankind Conference, E and EF sponsors, London, 1996: 1–15
5. The conduction of electricity through concrete10.1680/macr.1981.33.114.48 ↗
6. Monitoring the influence of water and ionic ingress on cover-zone concrete subjected to repeated absorption, ASTM10.1520/CCA10312J ↗
7. Examination of three methods for studying ion diffusion in cement pastes, mortars and concretes10.1007/BF02472720 ↗
8. Chemical composition of cement pore solutions10.1016/0008-8846(89)90022-7 ↗
9. Shi, C., Stegemann, J.A., Caldwell, R.J., Effect of supplementary cementing materials on the specific conductivity of pore solution and its implications on the rapid chloride permeability test (AASHTO T277 and ASTM C1202) results, Am Concr Inst Matls J, 1998:389–394.
10. Relation between resistivity and corrosion rate of reinforcements in carbonated mortar made with several cement types
11. Andrade, C., Alonso, C., Goni, S.,Possibilities for electrical resistivity to universally characterise mass transport processes in concrete, In: R.K.Dhir and M.R. Jones editors. Proceedings of the Concrete 2000 Conference, Vol. 2, E and FN Sponsors, London, 1993:1639–1652.
12. Influence of degree of saturation on the resistivity of concrete and the corrosion rate of steel reinforcement10.1016/0008-8846(93)90102-F ↗
13. Permanent corrosion monitoring
14. Schieß1 P, Raupach, M, New approavhes for monitoring the corrision risk for the reinforcement-installation of sensors, Proceedings of the concrete across Borders Conference, Odense, Denmark, 1994;1:65–77.
15. McCarter WJ, A study of moisture movement in concrete using a novel ac impedance spectroscopy technique, Final Report No. GR/F26645, Engineering and Physical Sciences Research Council (EPSRC), Swindon, UK, 1992;21.
16. Properties of concrete in the cover zone: developments in monitoring techniques10.1680/macr.1995.47.172.243 ↗
17. McCarter WJ, Chrisp TM, Ezirim, H, Basheer PAM, In-situ evaluation of properties of concrete in the cover-zone, In: RK Dhir and MR Jones editors. Proceedings of the Concrete Repair, Rehabilitation and Protection Conference, Dundee, 1996: 113–123, E and FN Sponsors.
18. Watson DW, McCarter WJ, The efficacy of hydrophobic surface treatments for concrete and their influence on moisture movement within the cover zone, Proceedings of the International Conference on New Requirements for Materials and Structures, Prague, 1998: 23–28, (ISBN 80-01-01838-5).
19. Tuutti K, Effect of cement type and different additions on service life, In: RK Dhir and MR Jones editors. Proceedings of the Concrete 2000 Conference, Vol. 2, E and FN Sponsors, London, 1993;2:1285–1295.
20. Properties of concrete in the cover zone: water penetration, sorptivity and ionic ingress10.1680/macr.1996.48.176.149 ↗