In-situ assessment of physical performance and degradation analysis of rendering walls
Source abstract
Abstract
Abstract The use of in-situ diagnostic techniques can lead to a more accurate evaluation of the performance level of facade claddings. The paper aims to evaluate the advantages of using visual inspection and selected in-situ techniques (infrared thermography, Karsten tubes and moisture meter) for the evaluation of the physical performance of renders and their state of deterioration. The main objective of the study is to propose a methodology for in-situ inspections with a low degree of intrusion for the evaluation of physical in-service performance of renders applied on external walls. Three experimental campaigns were performed and different types of renders were analyzed for several in-service conditions. This work enabled the identification of the various factors that affect the results of the selected in-situ techniques. Furthermore, it was made evident, that there are advantages in the cross-comparison of different results, which in certain situations can complement the visual inspection.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Thermography and Photoacoustic Techniques · Conservation Techniques and Studies · Building Energy and Comfort Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. On-site performance assessment of rendering façades for predictive maintenance10.1108/02630801111132812 ↗
2. In-situ techniques of mechanical performance and degradation analysis of rendering walls10.1515/rbm-2013-6606 ↗
3. Review of NDT methods in the assessment of concrete and masonry structures10.1016/S0963-8695(00)00032-3 ↗
4. Stains in facades’ rendering – diagnosis and maintenance techniques’ classification10.1016/j.conbuildmat.2006.08.023 ↗
5. Addleson · 1991 · 588
6. Flow and changes in appearance
7. Duarte R, Flores-Colen I, de Brito J. In-Situ Testing Techniques for In-Service Evaluation of Water Penetration in Rendered Façades - The Portable Moisture Meter and Karsten Tube. 12th DBMC International Conference on Durability of Building Materials and Components, Porto: 1307–1314 (2011).
8. Expected render performance assessment based on impact resistance in situ determination10.1016/j.conbuildmat.2009.05.003 ↗
9. ASTM C 1060, Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings. ASTM: American Society for Testing and Materials (2003).
10. BS EN 13187, Thermal performance of buildings - Qualitative detection of thermal irregularities in building envelopes - Infrared method. BSI: British Standards Institution (1999).
11. ISO 6781, Thermal insulation - Qualitative detection of thermal irregularities in building envelopes - Infrared method. ISO: International Organization for Standardization (1983).
12. Assessment technologies for sewer system rehabilitation10.1016/S0926-5805(97)00071-X ↗
13. Evaluation of building materials using infrared thermography10.1016/j.conbuildmat.2005.06.049 ↗
14. Ibarra-Castanedo C, Genest M, Piau JM, Guibert S, Bendada AH, Maldague X. Chapter 14: Active Infrared Thermography Techniques for the Nondestructive Testing of Materials. Ultrasonic and Advanced Methods for Nondestructive Testing and Material Characterization, Editor: C.H. Chen, World Scientific Publishing, 325–348 (2007).10.1142/9789812770943_0014 ↗
15. Active IR-applications in civil engineering10.1016/S1350-4495(02)00145-7 ↗
16. Maldague XP. Theory and Practice of Infrared Technology for Nondestructive Testing. John Wiley & Sons, Inc. (2001).
17. Hellier C, Hellier C. Handbook for Nondestructive Evaluation, McGraw-Hill Education (2003).
18. Emissivity considerations in building thermography
19. Application of infrared thermography for the investigation of historic structures10.1016/j.culher.2003.07.002 ↗
20. Infrared thermography for building diagnostics10.1016/S0378-7788(01)00105-0 ↗
21. Application of infrared thermography to the non-destructive testing of concrete and masonry bridges10.1016/S0963-8695(02)00060-9 ↗
22. In-situ assessment of structural timber elements of a historic building by infrared thermography and ultrasonic velocity10.1016/j.infrared.2006.06.012 ↗
23. Application of infrared thermography and geophysical methods for defect detection in architectural structures10.1016/j.engfailanal.2004.12.030 ↗
24. Use of IR thermography for the assessment of surface-water drainage problems in a historical building, Ağzıkarahan (Aksaray)10.1016/j.ndteint.2004.11.003 ↗
25. Improvement of building wall surface temperature measurements by infrared thermography10.1016/j.infrared.2005.01.001 ↗
26. Validation of in situ applicable measuring techniques for analysis of the water adsorption by stone10.1016/j.proche.2013.03.039 ↗
27. RILEM. Water absorption under low pressure. Pipe method. Test N II.4, Tentative recommendations. RILEM; 1980.
28. LNEC. Testing procedures sheet, Renders FE Pa 39.1 – water absorption under low pressure test. LNEC; 2002.
29. Kunzel · 2004
30. Massari · 1993
31. Tavares M, Magalhães A, Veiga M, Aguiar J. Diagnosis methods for coatings of ancient buildings. Importance and applicability of in situ tests (in Spanish). In: Revista Boletín del Instituto Andaluz del Patrimonio Histórico, available at [access July 2014].
32. What is the moisture meter trying to tell us?10.1108/02630800210456814 ↗
33. Menezes · 2012 · 106
34. ASTM · 2004