Abstract

Abstract In order to reduce the amount of concrete and self-weight of flat slabs, plastic void formers are used in slabs. The most critical areas of flat slabs are slab–column junctions and the zones where huge concentrated loads act. This area is more prone to punching shear failure. The cross section of concrete in reinforced concrete slabs with plastic void formers is significantly smaller, and hence the punching shear capacity of such junctions is insufficient. This article discusses the results of an experimental and theoretical study that investigated the punching shear capacity of reinforced concrete biaxial voided slabs. In order to increase the punching shear capacity of flat slabs, shear reinforcement is provided between voids in the concrete ribs. Slabs with void-forming inserts placed in the entire slab area, voided slabs with solid cross shapes and voided slabs with solid heads were analysed in this study. A method to calculate punching shear capacity based on EC2 methodology has been proposed. The results obtained for the punching shear capacity of the experimental slabs were verified with the EC2 methodology, and a method to calculate the length of the punching shear perimeter has been proposed.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. Evaluation of punching shear strength of voided transfer slabs10.1680/macr.14.00080 ↗
2. Punching behavior of biaxial hollow slabs10.1016/S0958-9465(01)00071-3 ↗
3. Flexural capacity and stiffness of monolithic biaxial hollow slabs10.3846/13923730.2014.917122 ↗
4. Predicting post-punching shear response of slab-column connections
5. Experimental response of FRP reinforced members without transverse reinforcement: failure modes and design issues10.1016/j.compositesb.2016.01.002 ↗
6. Crack propagation in concrete with silica particles10.4028/www.scientific.net/AMR.842.470 ↗
7. Punching shear behavior of lightweight fiber reinforced concrete slabs10.1016/j.compositesb.2016.06.045 ↗
8. Numerical simulation of the punching shear behaviour of self-compacting fibre reinforced flat slabs10.1016/j.conbuildmat.2014.10.003 ↗
9. Punching shear strengthening of two-way flat slabs using CFRP rods10.1016/j.compstruct.2012.11.028 ↗
10. Experimental study on the effect of anchorage systems on RC beams strengthened using FRP10.1016/j.compositesb.2016.02.001 ↗
11. Assessment of the effectiveness of steel fibre reinforcement for the punching resistance of flat slabs by experimental research and design approach10.1016/j.compositesb.2015.03.050 ↗
12. Strengthening of flat slabs with FRP fan for punching shear10.1016/j.compstruct.2014.08.041 ↗
13. Analysis of fire resistance of concrete with polypropylene or steel fibers10.1016/j.conbuildmat.2016.06.055 ↗
14. Design of PC beam-column joint applied X-braced bars in the segmented structural system10.3846/13923730.2014.914080 ↗
15. Punching shear design of footings: critical review of different code provisions10.1002/suco.201300092 ↗
16. Probability based design of punching shear resistance of column to slab connections10.3846/13923730.2015.1043339 ↗
17. Punching behaviour of RC flat slabs under reversed horizontal cyclic loading10.1016/j.engstruct.2016.03.007 ↗
18. Eurocode 2, Design of Concrete Structures — Part 1–1: General Rules and Rules for Buildings, EN 1992-1-1, 2004.
19. EN 12390-3 Testing hardened concrete – Part 3: Compressive strength of test specimens, 2009.