journal article·2018-06

Behavior of high-strength concrete slender columns strengthened with steel fibers under concentric axial loading

Chung-Chan Hung, Fuo-Yao Hu

Publisher page

Abstract

Abstract The deflection demand of slender reinforced concrete columns could be magnified substantially due to its interaction with the axial load, i.e., the P-Delta effect. This study experimentally investigated the behavior of ten slender high-strength concrete columns under concentric axial loads. The experimental variables were the amounts of confinement steel and steel fibers. The adopted high-strength concrete material had an average compressive strength of about 100 MPa. When it was reinforced with steel fibers at a volume fraction of 0.75% or more, it showed the characteristics of high performance fiber reinforced concrete, i.e., tensile strain hardening behavior and multiple narrow cracks. The behavior of the slender high-strength columns was evaluated using various performance measures, such as the failure type, peak strength, dilatation, ductility, steel reinforcement strain, and the P-Delta effect. The results showed that all the columns failed significantly due to the adverse P-Delta effect. The inclusion of steel fibers with a volume fraction of 0.75% or more effectively restrained concrete spalling and crushing and also promoted multiple narrow cracking patterns in the column. In particular, the inclusion of a 1.5% volume fraction of steel fibers enabled the column without steel confinement to exhibit comparable behavior to that of the control specimen that was detailed according to current codes of practice. Furthermore, reasonably accurate equations were suggested for predicting the axial strength of the tested slender, high-strength concrete columns.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Experimental tests on eccentrically loaded high strength concrete columns
2. High-strength concrete columns confined by rectangular ties10.1061/(ASCE)0733-9445(1994)120:3(783) ↗
3. Tests of eccentrically loaded high-strength concrete columns
4. Behaviour of fibre-reinforced RPC columns under different loading conditions10.1016/j.conbuildmat.2017.08.173 ↗
5. Studies on carbon fiber polymer confined slender plain and steel fiber reinforced concrete columns10.1016/j.engstruct.2015.08.011 ↗
6. Studies on high-strength concrete columns under eccentric compression
7. Experimental behaviour of steel fiber high strength reinforced concrete and composite columns10.1016/j.jcsr.2012.02.017 ↗
8. Behavior of ultra-high performance fiber reinforced concrete columns under pure axial loading10.1016/j.engstruct.2015.05.009 ↗
9. Slender high-strength concrete columns subjected to eccentric loading10.1061/(ASCE)0733-9445(1998)124:3(233) ↗
10. Slenderness effects in high-strength concrete columns10.1139/l91-093 ↗
11. Behavior of RC slender columns under unequal eccentricities and skew angle loads at the ends10.1016/j.engstruct.2012.02.017 ↗
12. Strength and ductility of HSC and SCC slender columns subjected to short-term eccentric load
13. Experimental research on high strength concrete slender columns subjected to compression and biaxial bending forces10.1016/j.engstruct.2007.12.005 ↗
14. Stress-strain relationship of high-strength fiber concrete in compression10.1061/(ASCE)0899-1561(1999)11:1(21) ↗
15. Stress-strain behavior of steel-fiber high-strength concrete under compression
16. Compressive stress-strain behavior of normal and high-strength carbon fiber concrete reinforced with steel spirals
17. Strength and behavior of confined steel fiber reinforced concrete columns
18. Behavior of steel fiber-reinforced high-strength concrete columns under uniaxial compression10.1061/(ASCE)ST.1943-541X.0000211 ↗
19. E.K. Balanji, M. Sheikh, M.N. Hadi, Behaviour of high strength concrete columns reinforced with steel fibres under different eccentric loads, in: Australasian Structural Engineering Conference: ASEC, 2016 (p. 115). Engineers Australia.
20. Experimental behavior of precast HSFRC columns in steel socket foundation under cyclic loads10.1016/j.engstruct.2015.07.052 ↗
21. Seismic behavior of synthetic fiber-reinforced circular columns
22. Proposed classification of HPFRC composites based on their tensile response10.1617/s11527-006-9103-2 ↗
23. Tensile response of HPFRC composites using twisted polygonal steel fibers
24. Mechanical properties and self-healing evaluation of strain-hardening cementitious composites with high volumes of hybrid pozzolan materials10.1016/j.compositesb.2017.09.005 ↗
25. Simple and effective models to predict the compressive and tensile strength of HPFRC as the steel fiber content and type changes10.1016/j.compositesb.2017.11.003 ↗
26. Impact of natural weathering on medium-term self-healing performance of fiber reinforced cementitious composites with intrinsic crack-width control capability10.1016/j.cemconcomp.2017.03.018 ↗
27. Experimental test methods to determine the uniaxial tensile and compressive behaviour of ultra high performance fibre reinforced concrete (UHPFRC)10.1016/j.conbuildmat.2012.04.030 ↗
28. Hybrid rotating/fixed-crack model for high-performance fiber-reinforced cementitious composites
29. Properties of strain hardening ultra high performance fiber reinforced concrete (UHP-FRC) under direct tensile loading10.1016/j.cemconcomp.2013.12.015 ↗
30. Cyclic behavior of UHPFRC flexural members reinforced with high-strength steel rebar10.1016/j.engstruct.2016.05.008 ↗
31. High-strength steel reinforced squat UHPFRC shear walls: cyclic behavior and design implications10.1016/j.engstruct.2017.02.068 ↗
32. Effect of matrix ductility on deformation behavior of steel-reinforced ECC flexural members under reversed cyclic loading conditions
33. Modeling the shear hysteretic response for high performance fiber reinforced cementitious composites10.1016/j.conbuildmat.2012.12.010 ↗
34. Three-dimensional model for analysis of high performance fiber reinforced cement-based composites10.1016/j.compositesb.2012.08.004 ↗
35. Application of Engineered Cementitious Composites (ECC) in interior beam–column connections for enhanced seismic resistance10.1016/j.engstruct.2014.03.026 ↗
36. Behavior of HPFRC connections for precast concrete frames under reversed cyclic loading10.15554/pcij.11011998.58.71 ↗
37. Vulnerability and improvement of reinforced ECC flexural members under displacement reversals: experimental investigation and computational analysis10.1016/j.conbuildmat.2016.01.019 ↗
38. Innovative ECC jacketing for retrofitting shear-deficient RC members10.1016/j.conbuildmat.2016.02.077 ↗
39. Cyclic responses of reinforced concrete composite columns strengthened in the plastic hinge region by HPFRC mortar10.1016/j.compstruct.2012.01.025 ↗
40. Medium-term self-healing evaluation of Engineered Cementitious Composites with varying amounts of fly ash and exposure durations10.1016/j.conbuildmat.2016.05.021 ↗
41. Seismic behavior of a coupled wall system with HPFRC materials in critical regions10.1061/(ASCE)ST.1943-541X.0000393 ↗
42. ACI (American Concrete Institute) Committee 318, ACI 318 Building code requirements for structural concrete (318-14). ACI-318, Farmington Hills, Michigan, 2014.
43. ACI (American Concrete Institute) Innovation Task Group (ITG) · 2007