journal article·2019-04Open access

Influence of cavity insulation on the fire resistance of light gauge steel framed walls

Anthony Deloge Ariyanayagam, Mahen Mahendran

Abstract

Light gauge steel framed (LSF) walls are used in fire compartmentation to prevent the spread of fire, smoke and toxic gases. The fire behavioural characteristics of non-load bearing LSF walls are different from those of load bearing walls. In non-load bearing LSF walls, fire penetration to the ambient side is to be prevented for insulation and integrity criteria whereas in load bearing walls, steel studs need to be protected from heat for structural adequacy also. This paper investigates the fire resistance of non-load bearing and load bearing LSF walls with and without cavity insulation. It presents the details of a series of standard fire tests conducted to investigate the effect of cavity insulation in both load bearing and non-load bearing LSF walls. The use of cavity insulation increased the fire resistance level (FRL) of non-load bearing walls, while it significantly reduced the FRL of load bearing walls. A finite element parametric study was then conducted for LSF walls lined with both single and double layers of plasterboards. Both thermal and structural fire performance results of LSF walls from finite element analyses are presented and compared in this paper. These results showed that FRL of cavity insulated non-load bearing LSF walls increases by 10–20 min, while it is significantly reduced for load bearing LSF walls with load ratios below 0.7. This study highlights both the beneficial and detrimental effects of cavity insulated LSF walls exposed to fire.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Load-Bearing Analysis · Fire effects on concrete materials · Seismic Performance and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. The effectiveness of thermal insulation in lightweight steel-framed walls with respect to its position10.3390/buildings7010013 ↗
2. Energry efficiency and thermal performance of lightweight steel framed (LSF) construction: a review10.1016/j.rser.2017.04.066 ↗
3. Standards Australia 2014, AS1530.4-2014, Methods for fire tests on building materials, components and structures – Fire resistance test of elements of construction, Sydney, Australia.
4. Fire resistance of load bearing steel-stud walls protected with gypsum board: a review10.1023/A:1015401029995 ↗
5. Factors influencing fire resistance of load bearing steel stud walls10.1007/s10694-005-3730-y ↗
6. Experimental study of load bearing cold-formed steel wall systems under fire conditions10.1016/j.tws.2013.01.005 ↗
7. Full-scale fire experiments on load-bearing cold-formed steel walls lined with different panels10.1016/j.jcsr.2012.07.031 ↗
8. An analysis of the structural behaviour of axially loaded full-scale cold-formed thin-walled steel structural panels tested under fire conditions10.1016/j.tws.2004.07.008 ↗
9. Experimental study of load bearing light gauge steel frame walls exposed to realistic design fires10.1260/2040-2317.5.4.291 ↗
10. Fire tests of load bearing LSF walls made of hollow flange channel sections10.1016/j.jcsr.2015.07.020 ↗
11. Fire tests of magnesium oxide board lined light gauge steel frame wall systems10.1016/j.firesaf.2017.03.004 ↗
12. Fire tests of non-load bearing light gauge steel frame walls lined with calcium silicate boards and gypsum plasterboards10.1016/j.tws.2017.02.005 ↗
13. Thermal performance of cold-formed thin-walled steel panel systems in fire10.1016/S0379-7112(02)00090-5 ↗
14. Experimental studies of non-load bearing steel wall systems under fire conditions10.1016/j.firesaf.2012.06.009 ↗
15. Fire performance of load bearing LSF wall systems made of low strength steel studs10.1016/j.tws.2018.05.018 ↗
16. Investigating the fire performance of LSF wall systems using 3-D finite element analyses10.1108/JSFE-04-2016-0002 ↗
17. EN 1991-1-2, Eurocode 1: Actions on Structures, Part 1.2: Actions on Structures Exposed to Fire, European Committee for Standardization, Brussels, 2002.
18. Kaitila · 2002
19. Finite element modelling of load bearing cold-formed steel wall systems under fire conditions10.1016/j.engstruct.2013.06.022 ↗
20. Numerical modelling of load bearing light gauge steel frame walls systems exposed to realistic design fires10.1016/j.tws.2014.01.003 ↗
21. Mechanical properties of cold-formed steels at elevated temperatures10.1016/j.tws.2010.08.004 ↗
22. EN 1993-1-3, Eurocode 3: Design of Steel Structures. Part 1-3: General Rules – Supplementary Rules, European Committee for Standardization, Brussels, 2005.
23. Fire peformance of cold-fromed steel wall panels and prediction of their fire resistance rating10.1016/j.firesaf.2013.12.003 ↗