Mechanical behaviour of connections between wood framed shear walls and foundations under monotonic and cyclic load
Source abstract
Abstract
Abstract Light timber structures have always been considered performing well during earthquakes, because of the high ratio between strength and mass. In platform frame constructions the task of resisting to the horizontal forces (wind, earthquake) is entirely left to the shear walls. The mechanical characterization of connections between the wall panels and the foundation and between the wall panels at different storeys is extremely important in order to investigate the global response of multi-storey buildings subjected to lateral loads. To this purpose different types of commercial or ad hoc designed connections system were experimentally investigated by means of monotonic and cyclic tests, in order to derive their stiffness and strength parameters. The experimental results confirmed the good mechanical behaviour of the proposed systems compared to the systems commonly adopted in practice. A simple engineering model is proposed to describe the force transmission mechanism between the connection elements.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Tree Root and Stability Studies · Wood Treatment and Properties · Bamboo properties and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (10)
Show source-provided references
1. Ni C, Karacabeyli E. Effect of overturning restraint on performance of shear walls. In: Proceedings of world conference timber engineering; CD ROM paper no. 2.3.1, Whistler BC, Canada; 2000.
2. Conte A, Piazza M, Tomasi R, Sartori T. Experimental investigation on connections between wood framed shear walls and foundations. In: Structural engineering world congress, Villa Erba, Cernobbio, Como, Italy; 2011.
3. EN 26891:1991. Timber structures – joints made with mechanical fasteners: general principles for the determination of strength and deformation. CEN, European Committee for Standardization, Brussels, Belgium; 1991.
4. zur Kammer T. Zum räumlichen tragverhalten mehrgeschossiger gebäude in holztafelbauart. Ph.D. thesis; Institut für Baukonstruktion und Holzbau der Technischen Universität Carolo-Wilhelmina zu Braunschweig; 2006.
5. Acler E, Piazza M, Tomasi R, Webber M. Experimental investigation of the behaviour of different types of connections between the XLAM panels and the concrete slab. In: Structural engineering world congress, Villa Erba, Como, Italy; 2011.
6. Dujic B, Klobacr S, Zarnic R. Shear capacity of cross-laminated wooden walls. In: Proceedings of world conference timber engineering, Miyazaki, Japan; 2008.
7. Gavric I, Ceccotti A, Fragiacomo M. Experimental cyclic tests on cross-laminated timber panels and typical connections. In: Proceedings of XIV ANIDIS conference, Bari, Italy; 2011.
8. Sandhaas C, van de Kuilen JW, Boukes L, Ceccotti A. Analysis of X-lam panel-to-panel connections under monotonic and cyclic loading. In: Proceeding of CIB-W18 meeting timber structures, paper no. 42-12-2, Dübendorf, Zürich; August 2009.
9. EN1995-1-1:2004. Design of timber structures Part 1-1: General-common rules and rules for building. CEN, European Committee for Standardization, Brussels, Belgium; 2004.
10. EN12512:2001/A1:2005. Timber structures – test methods – cyclic testing of joints made with mechanical fasteners. CEN, European Committee for Standardization, Brussels, Belgium; 2005.