Model for cover cracking of RC beams due to partial surface steel corrosion
Source abstract
Abstract
Abstract Cracking of the cover concrete due to steel corrosion is considered by many researchers to indicate the end-of-service life of corrosion-affected reinforced concrete (RC) structures. Numerous models have been developed to predict the time from corrosion initiation to cracking of the cover concrete. In the previous models, concrete with corroding steel bars was assumed to behave like a thick-walled cylinder under uniform internal pressure. Recent research publications have however, shown that steel corrosion is often concentrated on the surface of the steel that faces the direction of ingress of corrosion agents. This paper presents a model that relates the level of partial surface steel corrosion with the transverse and vertical strains measured on the exterior faces of corrosion-affected RC beams. The model assumes that the remaining section of the steel after corrosion is elliptical shaped. Finally, the model is calibrated with experimental data in the literature and it is shown that assuming uniform steel corrosion underestimates the internal pressure applied by the expansive corrosion products.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Infrastructure Maintenance and Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Morinaga S. Prediction of service lives of reinforced concrete buildings based on rate of corrosion of reinforcing steel. Report No. 23, Shimizu Corp., Japan; 1988. p. 82.
2. Cover cracking as a function of bar corrosion: Part 1 – experimental test10.1007/BF02472805 ↗
3. Modeling of time to corrosion-induced cover cracking in reinforced concrete structures10.1016/j.cemconres.2005.06.007 ↗
4. Analytical model for time to cover cracking in RC structures due to rebar corrosion10.1016/j.nucengdes.2005.10.011 ↗
5. Analytical model for corrosion-induced crack width in reinforced concrete structures
6. Factors controlling cracking of concrete affected by reinforcement corrosion10.1007/BF02480466 ↗
7. Model for prediction of time from corrosion initiation to corrosion cracking10.1016/j.cemconcomp.2006.11.004 ↗
8. Modelling cover-cracking due to reinforcement corrosion in RC structures
9. Analytical modeling of concrete cover cracking caused by corrosion reinforcement
10. Modelling the time-to-corrosion cracking in chloride contaminated reinforced concrete structures
11. Reinforcement corrosion and deflection of RC beams – an experimental critique of current test methods10.1016/S0958-9465(02)00076-8 ↗
12. Deflection of RC beams under simultaneous load and steel corrosion10.1680/macr.2003.55.4.405 ↗
13. Critical corrosion amount to cause cracking of reinforced concrete structures
14. Residual strength of corrosion-damaged reinforced concrete beams
15. Long-term performance of corrosion-damaged reinforced concrete beams
16. Control of corrosion-induced damage in reinforced concrete beams using carbon fiber-reinforced polymer laminates10.1061/(ASCE)1090-0268(2005)9:2(195) ↗
17. Behaviour of reinforced concrete beams strengthened with carbon fibre reinforced polymer laminates subjected to corrosion damage10.1139/l00-052 ↗
18. Lateral deformation of RC beams under simultaneous load and steel corrosion10.1016/j.conbuildmat.2009.08.005 ↗
19. Variation of steel loss and its effect on flexural capacity of RC beams corroded and repaired under load10.1016/j.conbuildmat.2009.11.012 ↗
20. Modeling corroded section configuration of steel bar in concrete structure10.1016/j.conbuildmat.2008.09.026 ↗
21. Comparison of two accelerated corrosion techniques for concrete structures
22. Behaviour of RC beams corroded under sustained service loads10.1016/j.conbuildmat.2009.06.005 ↗
23. Chloride-induced corrosion products of steel in cracked-concrete subjected to different loading conditions10.1016/j.cemconres.2008.11.001 ↗
24. Roberge · 1999
25. Effectiveness of impressed current technique to simulate corrosion of steel reinforcement in concrete10.1061/(ASCE)0899-1561(2003)15:1(41) ↗
26. Boresi · 1993