On the efficiency of flat slabs strengthening against punching using externally bonded fibre reinforced polymers

Duarte M. V. Faria, Jürgen Einpaul, António M. P. Ramos, Miguel Fernández Ruiz, Aurelio Muttoni

Abstract

One possibility for strengthening existing flat slabs consists on gluing fibre reinforced polymers (FRPs) at the concrete surface. When applied on top of slab–column connections, this technique allows increasing the flexural stiffness and strength of the slab as well as its punching strength. Nevertheless, the higher punching strength is associated to a reduction on the deformation capacity of the slab–column connection, which can be detrimental for the overall behaviour of the structure (leading to a more brittle behaviour of the system). Design approaches for this strengthening technique are usually based on empirical formulas calibrated on the basis of the tests performed on isolated test specimens. However, some significant topics as the reduction on the deformation capacity or the influence of the whole slab (accounting for the reinforcement at mid-span) on the efficiency of the strengthening are neglected. In this paper, a critical review of this technique for strengthening against punching shear is investigated on the basis of the physical model proposed by the Critical Shear Crack Theory (CSCT). This approach allows taking into account the amount, layout and mechanical behaviour of the bonded FRP’s in a consistent manner to estimate the punching strength and deformation capacity of strengthened slabs. The approach is first used to predict the punching strength of available test data, showing a good agreement. Then, it is applied in order to investigate strengthened continuous slabs, considering moment redistribution after concrete cracking and reinforcement yielding. This latter study provides valuable information regarding the differences between the behaviour of isolated test specimens and real strengthened flat slabs. The results show that empirical formulas calibrated on isolated specimens may overestimate the actual performance of FRP’s strengthening. Finally, taking advantage of the physical model of the CSCT, the effect of the construction sequence on the punching shear strength is also evaluated, revealing the role of this issue which is also neglected in most empirical approaches.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Wang JW, Tan KI. Punching shear behaviour of RC flat slabs externally strengthened with CFRP system. In: Proceedings of the 5th international conference on fibre-reinforced plastic for reinforced concrete structures (FRPRCS-5), vol. 2. London: Thomas Telford; 2001.
2. Strengthening of two-way concrete slabs with FRP composite laminates10.1016/S0950-0618(02)00092-2 ↗
3. Shear strengthening of interior slab–column connections using carbon fiber-reinforced polymer sheets10.1061/(ASCE)1090-0268(2003)7:2(145) ↗
4. Fiber-reinforced polymer strengthening of two-way slabs
5. Punching shear strength of reinforced concrete slabs strengthened with glass fiber-reinforced polymer laminates
6. CFRP strengthening for punching shear of interior slab–column connections
7. Ultimate behavior of CFRP strengthened RC flat slabs under a centrally applied load10.1016/j.compstruct.2004.10.017 ↗
8. Suter R, Moreillon L. “Renforcement de dalles en béton contre le poinçonnement au moyen d’armatures collées” (Strengthening of concrete slabs to punching using bonded reinforcement). Test Report. EIA Fribourg; 2007.
9. Flexure of two-way slabs strengthened with prestressed or nonprestressed CFRP sheets10.1061/(ASCE)1090-0268(2008)12:4(366) ↗
10. Punching shear strength of interior slab–column connections strengthened with carbon fiber reinforced polymer sheets10.1016/j.engstruct.2009.02.021 ↗
11. Prediction of punching shear strength of two-way slabs strengthened externally with FRP sheets10.1061/(ASCE)CC.1943-5614.0000177 ↗
12. Tests investigating the punching shear of a column–slab connection strengthened with non-prestressed or prestressed FRP plates10.1016/j.conbuildmat.2013.07.012 ↗
13. FRP-strengthened RC beams. I: review of debonding strength models10.1016/S0141-0296(01)00105-5 ↗
14. Punching shear of reinforced concrete slabs without transverse reinforcement
15. Punching of concrete slabs without shear reinforcement
16. Strengthening of flat slabs against punching shear using post-installed shear reinforcement
17. Strengthening of flat slabs with transverse reinforcement by introduction of steel bolts using different anchorage approaches10.1016/j.engstruct.2012.05.043 ↗
18. Retrofit of slab column interior connections using shear bolts
19. Teng · 2002
20. Design proposal to avoid peeling failure in FRP-strengthened reinforced concrete beams10.1061/(ASCE)CC.1943-5614.0000038 ↗
21. Background to the model code 2010 shear provisions – part II punching shear10.1002/suco.201200064 ↗
22. Applications of critical shear crack theory to punching of reinforced concrete slabs with transverse reinforcement
23. Non-axis-symmetrical punching shear around internal columns of RC slabs without transverse reinforcement”10.1680/macr.10.00098 ↗
24. Punching shear strength of steel fibre reinforced concrete slabs10.1016/j.engstruct.2012.02.009 ↗
25. Design for punching of prestressed concrete slabs10.1002/suco.201200028 ↗
26. Guandalini S. Poinçonnement symétrique des dalles en béton armé (Symmetric Punching of reinforced concrete slabs). École Polytéchinque Fédérale de Lausanne. PhD Thesis; 2005.
27. Tassinari L. Poinçonnement non symétrique des dalles en béton armé (Non-symmetric punching of reinforced concrete slabs). École Polytéchinque Fédérale de Lausanne. PhD Thesis; 2011.
28. Muttoni A, Fernández Ruiz M, Einpaul J. Punching strength of actual two-way slabs. In: 4th Fib congress, Mumbai, India; 2014. p. 6.
29. Experimental investigations on moment redistribution and punching shear of flat plates
30. Eurocode 2. Design of concrete structures—part 1–1: general rules and rules for buildings EN 1992-1-1; 2004.
31. Fib Fédération international du béton. Model Code 2010. Final Draft. Lausanne, Switzerland; 2010. p. 653.