journal article·2017-07

Monitoring chloride ion penetration in concrete with different mineral admixtures based on embedded chloride ion selective electrodes

Ming Jin, Linhua Jiang, Qiao Zhu

Publisher page

Abstract

Abstract In this paper the development of free Cl − content in various types of concrete was monitored by means of the embedded Ag/AgCl electrode. Moreover, the bound as well as total Cl − contents were determined through volumetric method. Besides, these mechanisms about the Cl − diffusion in different types of concrete are analyzed and discussed. Results revealed that real-time monitoring of free Cl − concentration in concrete was achieved based on the measurements of potentials of embedded electrodes and the diffusion law of free Cl − content followed Fick’s second law. In addition, the Freundlich isotherm was recommended to describe these relationships between free Cl − content and bound as well as total Cl − concentrations. As for the types of concrete with the addition of mineral admixture, lower total porosity and larger locked porosity have been found out. However, much more efforts should be paid to develop low-cost, robustness and long-term reliable Cl − selective sensors in order to achieve the wide application in concrete environment.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Concrete Corrosion and Durability · Smart Materials for Construction

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Durability of concrete—Degradation phenomena involving detrimental chemical reactions10.1016/j.cemconres.2007.09.015 ↗
2. Multiprobe chloride sensor for in situ monitoring of reinforced concrete structures10.1016/j.cemconcomp.2006.01.005 ↗
3. Standard Test Method for Acid-Soluble Chloride in Mortar and Concrete, American Society for Testing and Materials (ASTM) Philadelphia, PA, 2004.
4. Free and water soluble chloride in concrete10.1016/0008-8846(95)00042-B ↗
5. Chloride ion penetration into fly ash modified concrete during wetting–drying cycles10.1016/j.conbuildmat.2015.04.033 ↗
6. Non-destructive methods for measuring chloride ingress into concrete: state-of-the-art and future challenges10.1016/j.conbuildmat.2014.06.009 ↗
7. Effects of material and environmental parameters on chloride penetration profiles in concrete structures10.1016/j.cemconres.2006.09.005 ↗
8. Life-cycle performance of structures subject to multiple deterioration mechanisms10.1016/j.strusafe.2011.03.003 ↗
9. Analysis of the variability of chloride threshold values in the literature10.1002/maco.200905296 ↗
10. Non destructive determination of the free chloride content in cement based materials10.1002/maco.200390095 ↗
11. Sensor systems for use in reinforced concrete structures10.1016/j.conbuildmat.2004.03.008 ↗
12. Embeddable Ag/AgCl sensors for in-situ monitoring chloride contents in concrete10.1016/0008-8846(96)00104-4 ↗
13. Monitoring chloride concentrations in hardened cement pastes using ion selective electrodes10.1016/0008-8846(95)00218-9 ↗
14. Potentiometric determination of the chloride ion activity in cement based materials10.1007/s10800-009-0029-6 ↗
15. Sources of error in using silver/silver chloride electrodes to monitor chloride activity in concrete10.1016/S0008-8846(01)00544-0 ↗
16. Determination of the selectivity coefficient of a chloride ion selective electrode in alkaline media simulating the cement paste pore solution10.1016/j.jelechem.2009.11.010 ↗
17. Influence of fly ash fineness on strength, drying shrinkage and sulfate resistance of blended cement mortar10.1016/j.cemconres.2003.11.021 ↗
18. Improving the mechanical performance of high-grade slag cement by the addition of Portland cement and sulfoaluminate cement10.1016/j.conbuildmat.2012.04.041 ↗
19. Influence of cation type on diffusion behavior of chloride ions in concrete10.1016/j.conbuildmat.2015.09.033 ↗
20. Modeling of chloride diffusion in concrete immersed in CaCl2 and NaCl solutions with account of multi-phase reactions and ionic interactions10.1016/j.conbuildmat.2014.05.026 ↗
21. Investigation on the performance characteristics of chloride selective electrode in concrete10.1007/s11581-015-1485-0 ↗
22. Electrochemical characterization of a solid embeddable Ag/AgCl reference electrode for corrosion monitoring in reinforced concrete10.5796/electrochemistry.82.1040 ↗
23. Characterization of Ag/AgCl electrode manufactured by immersion in sodium hypochloride acid for monitoring chloride content in concrete10.1016/j.conbuildmat.2016.05.163 ↗
24. Standard Test Method for Water-Soluble Chloride in Mortar and Concrete, American Society for Testing and Materials (ASTM) Philadelphia, PA, 2008.
25. Time dependent diffusion in concrete—three laboratory studies10.1016/j.cemconres.2004.03.030 ↗
26. On the mathematics of time-dependent apparent chloride diffusion coefficient in concrete10.1016/j.cemconres.2007.01.006 ↗
27. Chloride binding of cement-based materials subjected to external chloride environment – a review10.1016/j.conbuildmat.2008.02.004 ↗
28. Possible states of chloride in the hydration of tricalcium silicate in the presence of calcium chloride10.1007/BF02473926 ↗
29. On the corrosion risk presented by chloride bound in concrete10.1016/S0958-9465(01)00021-X ↗
30. The influence of chloride binding on the chloride induced corrosion risk in reinforced concrete10.1016/S0010-938X(99)00083-9 ↗
31. Chloride threshold level for corrosion of steel in concrete10.1016/j.corsci.2007.05.007 ↗
32. Effect of carbon dioxide on chloride penetration and chloride ion diffusion coefficient of blended Portland cement mortar10.1016/j.conbuildmat.2007.06.002 ↗
33. Stability of Friedel's salt in carbonated concrete structural elements10.1016/S0008-8846(96)85010-1 ↗
34. Chloride binding capacity and binding isotherms of OPC pastes and mortars10.1016/0008-8846(93)90089-R ↗
35. Study of chloride binding and diffusion in GGBS concrete10.1016/S0008-8846(02)00712-3 ↗
36. The effect of supplementary cementitious materials on chloride binding in hardened cement paste10.1016/j.cemconres.2011.01.001 ↗
37. Modelling chloride diffusion in concrete – effect of fly ash and slag10.1016/S0008-8846(98)00192-6 ↗
38. Long term performance of chloride binding capacity in fly ash concrete in a marine environment10.1016/j.conbuildmat.2009.12.039 ↗
39. Transport processes for harmful species through concrete barriers made with mineral wastes10.1016/j.conbuildmat.2008.09.022 ↗
40. Model of chloride penetration into cracked concrete subject to drying–wetting cycles10.1016/j.conbuildmat.2012.05.027 ↗
41. Transport model of chloride ions in concrete under loads and drying-wetting cycles10.1016/j.conbuildmat.2016.02.167 ↗
42. Effect of chloride salt type on chloride binding behavior of concrete10.1016/j.conbuildmat.2012.07.079 ↗
43. Accelerated simulation of chloride ingress into concrete under drying–wetting alternation condition chloride environment10.1016/j.conbuildmat.2015.05.090 ↗
44. Chloride ion ingress distribution within an alternate wetting-drying marine environment area10.1007/s11431-011-4733-1 ↗
45. Stochastic improvement of inspection and maintenance of corroding reinforced concrete structures placed in unsaturated environments10.1016/j.engstruct.2012.03.011 ↗
46. Factors influencing chloride-binding in concrete10.1016/0008-8846(90)90083-A ↗
47. Influence of surfactants on chloride binding in cement paste10.1016/j.conbuildmat.2016.08.075 ↗
48. Electrochemical characterization of solid Ag/AgCl reference electrode with different electrolytes for corrosion monitoring of steel in concrete10.5796/electrochemistry.84.383 ↗
49. Electrochemical studies on the performance characteristics of alkaline solid embeddable sensor for concrete environments10.1016/j.snb.2007.10.059 ↗
50. Long-term relative performance of embedded sensor and surface mounted electrode for corrosion monitoring of steel in concrete structures10.1016/j.snb.2013.10.123 ↗
51. Diffusion potentials in porous mortar in a moisture state below saturation10.1016/j.electacta.2010.07.085 ↗
52. Research on the influence of distance between the improved Ag/AgCl RE and the steel on the corrosion evaluation in concrete10.20964/2016.09.50 ↗
53. Characterization of embeddable potentiometric thick-film sensors for monitoring chloride penetration in concrete10.1016/j.snb.2015.07.056 ↗