Numerical simulation and experimental investigation of the stray current corrosion of viaducts in the high-speed rail transit system
Source abstract
Abstract
Abstract The stray current corrosion coupled with fatigue can degrade the durability of viaducts in the high-speed rail transit system. To investigate the distribution status of the stray current field in the viaducts, the numerical simulation algorithm is established based on the finite element methods. Then, the corrosion development of steel bar with that of the stray current located at the anodic and cathodic regions is discussed in detail. Furthermore, the viaduct model is casted to verify the effectiveness of numerical simulation algorithm for the stray current field distribution. The results indicate that the simulation algorithm of stray current can provide the key basis for the safety assessment, maintenance and reinforcement, and the performance based design of the viaducts in high-speed rail transit system.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Smart Materials for Construction · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Report of the Ministry of Science and Technology of People’s Republic of China. The national medium to long range program for scientific and technological development of China (2006-2020). http://www.Most.Gov.Cn/Kjgh/Kjghzcq.
2. Bertolini · 2004
3. Corrosion behaviour of steel in concrete in the presence of stray current10.1016/j.corsci.2006.05.048 ↗
4. Experiment research of dynamic stray current interference on buried gas pipeline from urban rail transit10.1016/j.jngse.2013.09.003 ↗
5. European Standards. Protection against corrosion by stray current from direct current systems. Standard No.: EN 50162-2004. http://www.doc88.com/p-7068640722032.html.
6. British Standards. Railway applications — fixed installations — electrical safety, earthing and the return circuit part 2: provisions against the effects of stray currents caused by d.c. traction systems. Standard No.: BS EN 50122-2-2010. http://www.freestd.us/soft/154929.htm.
7. Method of sacrificial anode dual transistor-driving in stray current field10.1016/j.corsci.2015.06.006 ↗
8. History of stray traction current corrosion in the United States
9. Rail base corrosion problem for North American transit systems10.1016/j.engfailanal.2008.05.011 ↗
10. A study examining the effect of stray current on the integrity of continuous and discontinuous reinforcing bars10.1111/j.1747-1567.2010.00656.x ↗
11. A new time–frequency detection method of stray current field interference on metal structures10.1016/j.corsci.2003.09.007 ↗
12. Influence of alternating, direct and superimposed alternating and direct current on the corrosion of mild steel in marine environments10.1016/j.desal.2006.11.021 ↗
13. Mesoscopic model to simulate the mechanical behavior of reinforced concrete members affected by corrosion10.1016/j.ijsolstr.2009.10.023 ↗
14. Dynamic stray current evaluations on cut-and-cover sections of DC metro systems10.1109/TVT.2014.2304522 ↗
15. Stray current control in DC mass transit systems10.1109/TVT.2004.842462 ↗
16. Corrosion monitoring system for a reinforced concrete transit tunnel
17. A simulation tool to predict the impact of soil topologies on coupling between a light rail system and buried third-party infrastructure10.1109/TVT.2007.909312 ↗
18. Distribution of the traction teturn current in AC and DC electric railway systems10.1109/TPWRD.2003.817786 ↗
19. Estimation of stray current from a DC electrified railway and impressed potential on a buried pipe10.1109/TPWRD.2012.2211623 ↗
20. Simulation model for drainage protection of earth-return circuits laid in stray currents area10.1007/s00202-002-0119-5 ↗
21. Analysis of the insulation resistances of a high-speed rail transit system viaduct for the assessment of stray current interference. Part 1: Measurement10.1016/j.epsr.2013.04.011 ↗
22. Analysis of the insulation resistances of a high-speed rail transit system viaduct for the assessment of stray current interference. Part 2: Modeling10.1016/j.epsr.2013.04.012 ↗
23. Numerical modeling of stray current corrosion of ductile iron pipe induced by foreign cathodic protection system10.1007/s12540-013-4011-9 ↗
24. Remote corrosion monitoring of the RC structures using the electrochemical wireless energy-harvesting sensors and networks10.1016/j.ndteint.2011.06.007 ↗
25. Electrochemical characterization of the solid-state reference electrode based on NiFe2O4 film for the corrosion monitoring of RC structures10.1016/j.snb.2012.04.004 ↗
26. British Standards. Cathodic protection of steel in concrete. Standard No.: BS EN ISO 12696-2012. http://www.freestd.us/soft1/562488.htm.