Reduction in the permeability of plastic concrete for cut-off walls through utilization of silica fume

A.R. Bagheri, M. Alibabaie, M. Babaie

Publisher page

Abstract

Abstract Principal requirements for plastic concretes used in construction of cut off walls of dams, are a low enough elastic modulus compatible with the surrounding soil, adequate strength for loads sustained and adequate water tightness. Therefore means of reducing permeability without unduly increasing elastic modulus are important areas of research needed in this field. Considering the effectiveness of silica fume in reducing the permeability of normal and high performance concretes, in this research the extent of improvement in impermeability of plastic concrete through utilization of silica fume was investigated. The results obtained showed the substantial effect of incorporation of silica fume in reducing permeability and at the 15% replacement level of cement by silica fume, the coefficient of permeability was reduced 80 times. The utilization of silica fume also increased the strength and elastic modulus of plastic concretes. However the improvement in impermeability was more dominant and by increasing the water to cementitious materials ratio of plastic concrete containing silica fume it was possible to maintain the strength and elastic modulus at the level of control plastic concrete but achieve a 10 times reduction in permeability.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Innovative concrete reinforcement materials · Infrastructure Maintenance and Monitoring · Grouting, Rheology, and Soil Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. International Committee on Large Dams. Filling Materials for water tight cut off walls, Bulletin 51, 1985.
2. Kahl Thomas W, Kauschinger Joseph L, Perry Edwards B. Plastic concrete cut off walls for earth dams, US Army Corps of Engineers, Technical Report No. REMR-GT-15, Waterways Experimental station, Vicksburg, MS, P71, March 1991.
3. Neville · 1995
4. ACI Committee 234-R96, Guide for the use of silica fume in concrete, American Concrete Institute Manual of concrete Practice, 2003.
5. Concrete Society, Microsilica in concrete, Technical report No 41, London 1993.
6. Aitcin · 1999
7. Dolen TH, Benavidez AA. Properties of low strength concrete for Meeks cabin dam modification project. ASTM STP 1331, American Society for Testing and Materials, 1998.10.1520/STP13075S ↗
8. Ramachandran · 1992
9. U.S.B.R-4913-92, “Procedure for Water Permeability of Concrete” United States Bureau of Reclamation, 1992.
10. Naghipoor N, Soroush A. Experimental study on permeability of plastic concrete, In: Third international conference on concrete, Tehran, Iran, 2000.
11. Drilling Fluid Materials Bentonite, OCMA Specification NO.DFCD 4,1985.
12. Drilling Fluid Materials, American Petroleum Institute, Spec 13A, 1998.
13. Famili H, Bagheri AR. Effect of Iranian produced silica fume on water demand and strength of concrete, Sixth NCB International seminar on cement and building materials, New Delhi, 1998.
14. Hewlett · 2000