Influence of moderate temperatures on the bond between carbon fibre reinforced polymer bars (CFRP) and concrete
Source abstract
Abstract
[EN] This study analyzes the influence of different environmental conditions (freeze/thaw, 5ºC, 20ºC, 40ºC and 80ºC) on the bond of different types of CFRP bars (sanded, ribbed, and deformed and textured) and the results are compared with those obtained on tests with Steel bars. The tests included Pullout, SEM, AFM, TGA and DSC. The experimental results show that there are large differences in the behaviour of different types od CFRP bar and also that temperatura variations have an influence on their bond due to changes in the mechanical properties of the polymer resin. Ribbed CFRP bars have the highest "tau" max values, similar to those obtained from Steel bars, except at high temperaturas (80ºC). Their failure mode varies according to the relationship between the shear resistance of the ribs and that of the concrete. Sanded bars have significantly lower "tau"max, but do show good initial bond. Failure usually occurs due to weakening of the bond between the sanded layer and the bar. Deformed and textured bars also have low "tau"max values due to the design of their surface geometry, with widely separated shallow grooves. Bond failure occurs due to shear of the concrete embedded in the grooves and at high temperaturas there is also a separation of the textured layer.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Smart Materials for Construction · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. G.H. Koch, M.P.H. Brongers, N.G. Thompson, Y.P. Virmani, J.H. Payer, Corrosion Costs and Preventive Strategies in the United States, NACE, Publication No. FHWA-RD-01-156, USA, (April 2015).
2. R.J. Keesler, R.G. Powers, Corrosion of Epoxy Coated Rebars, Keys Segmental Bridge, Monroe County. Report No. 88-8A, Florida Dept. of Transportation, Materials Office, Corrosion Research Laboratories, Gainesville, Fla, 1988.
3. Gangarao · 2007
4. Association for Advanced Composite Technology on Construction Field (ACC), Application Study Group Report: A case study on the lifecycle cost of a concrete structure using CFRM, Japan, June 2002.
5. ACI, ACI 440.1R-06, Guide for the Design and Construction of Concrete Reinforced with FRP Bars, ACI Committee 440, American Concrete Institute (ACI), 2006.10.1061/40753(171)158 ↗
6. CNR-DT 200/2004 · 2004
7. CAN/CSA-S806-02 · 2002
8. Japan Society of Civil Engineers (JSCE), Recommendation for Design and Construction of Concrete Structures using Continuous fiber Reinforcing Materials, Concrete engineering series n°23, Tokyo, Japan, 1997.
9. L.J. Malvar, Bond Stress–Slip Characteristics of FRP Rebars. Technical Report TR 2013-SHR, Naval Facilities Engineering Service Center, Port Hueneme, California, CA 93043–4328, February 1994, p. 45.
10. Analytical modelling of bond between FRP reinforcing bars and concrete
11. Development length of FRP straight rebars10.1016/S1359-8368(02)00051-3 ↗
12. Cosenza · 1996
13. Behavior and modeling of bond of FRP rebars to concrete10.1061/(ASCE)1090-0268(1997)1:2(40) ↗
14. Bond between carbon fiber reinforced polymer bars and concrete. I. Experimental study10.1061/(ASCE)1090-0268(2003)7:2(154) ↗
15. R. Eligehausen, E.P. Popov, V.V. Bertero, Local Bond Stress–Slip Relationships of Deformed Bars Under Generalized Excitations, Report No. 83/23, EERC, University of California, Berkeley, 1983.
16. Bond between carbon fibre-reinforced polymer (CFRP) bars and ultra high performance reinforced concrete (UHPFEC): experimental study10.1016/j.conbuildmat.2010.02.006 ↗
17. Experimental study of bond behavior between concrete and FRP bars using a pull-out test10.1016/j.compositesb.2009.07.003 ↗
18. Evaluation of bond using FRP rods with axisymmetric deformations10.1016/S0950-0618(99)00038-0 ↗
19. Mechanical and bond properties of new generation of carbon fiber reinforced polymer reinforcing bars for concrete structures10.1139/l02-013 ↗
20. Bond behavior of fiber reinforced polymer bars under direct pullout conditions10.1061/(ASCE)1090-0268(2004)8:2(173) ↗
21. R. Masmoudi, A. Alvarez, J. Dubois, Thermal Effect on Bond Properties of FRP Bars Embedded in Concrete, 33rd Annual General Conference of the Canadian Society for Civil Engineering, June 2005, pp. 3115–3124.
22. Effect of FRP bar degradation on interface bond with high strength concrete10.1016/j.cemconcomp.2008.05.006 ↗
23. ACI 440.3R-04, Guide test methods for Fiber–Reinforced Polymers (FRPs) for Reinforcing or Strengthening Concrete Structures, ACI Committee 440, American Concrete Institute, Farmington Hills, Michigan, USA, 2004.
24. Box · 2005
25. Effect of surface preconditioning on bond of carbon fibre reinforced polymer rods to concrete10.1016/j.cemconcomp.2007.04.010 ↗
26. A reevaluation of test data on development length and splices
27. E. Makitani, I. Irisawa, N. Nishiura, Investigation of bond in concrete member with fiber reinforced plastic bars, in: A. Nanni, C.W. Dolan (Eds.), Proc. Int. Symp. on Fiber-Reinforced-Plastic Reinforcement for Concrete Struct, 1993, ACI SP-138.
28. Pullout and bond of glass–fibre rods embedded in concrete and cement grout10.1007/BF02472934 ↗
29. Bond clause proposal for FRP-bars/rods in concrete based on CEB/FIP Model Code 90. Part 1: design bond stress for FRP reinforcing bars10.1680/stco.2006.7.2.47 ↗
30. Bond of reinforcement to concrete – experimental results
31. Fried · 2003
32. Bond strength of fiber reinforced polymer rebars in normal strength concrete10.1061/(ASCE)1090-0268(2005)9:3(203) ↗