journal article·2013-05

Reliability of shear-deficient RC beams strengthened with CFRP-strips

Saleh H. Alsayed, Nadeem A. Siddiqui

Publisher page

Abstract

Abstract Effectiveness of externally bonded FRP-strips on the side faces of RC beams in the strengthening of shear-deficient RC beams is well established. However, how the design parameters such as fiber orientation, strip-width, and spacing between the FRP-strips influences the reliability of strengthened beams is not very well known. In the present study, a simplified probabilistic procedure based on Monte Carlo Simulation technique has been presented to study the influence of externally bonded FRP-strips on the reliability of shear-deficient RC beams. To illustrate the procedure, reliability analysis was carried out for the six RC beam specimens of 2 m span. Two of these specimens were shear-deficient control specimens, and the remaining four were the similar beams which were shear-strengthened using CFRP-strips. Out of these four strengthened specimens, in the first two specimens, CFRP-strips were externally bonded at 30° whereas in the other two CFRP-strips were attached at 90° with the longitudinal axis of the beam. All these beams were tested in the lab until failure to obtain their ultimate load carrying capacities. Reliability analysis was then carried out for a range of applied nominal loads, varying from service to ultimate. Three parametric studies (i) effect of fiber orientation; (ii) effect of strip width; and (iii) effect of strip-spacing on reliability of strengthened beams were carried out for two different service loads, taken 60% and 70% of tested beams’ capacity. The results indicate that when the service load is 60% (or less) of the ultimate load, beam is sufficiently reliable for all the values of the fiber orientation ranging from 30° to 60° from the longitudinal axis of the beam. However, when the applied load is 70% (or more) of the ultimate load, it is difficult to achieve the desired reliability just by attaching the inclined CFRP strips at a certain angle. The desired reliability, in this case, can be achieved by altering the strip-width or strip-spacing or the both.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Experimental investigation of RC beams strengthened with externally bonded FRP composites
2. Seismic rehabilitation of corner RC beam-column joints using CFRP composites10.1061/(ASCE)CC.1943-5614.0000124 ↗
3. Seismic response of FRP-upgraded exterior RC beam-column joints10.1061/(ASCE)CC.1943-5614.0000067 ↗
4. Seismic behavior of As-built, ACI-complying and CFRP-repaired exterior RC beam-column joints10.1061/(ASCE)CC.1943-5614.0000186 ↗
5. Textile-reinforced mortar (TRM) versus FRP as strengthening material of seismically deficient RC beam-column joints10.1061/(ASCE)CC.1943-5614.0000222 ↗
6. Shear strengthening of reinforced concrete beams using epoxy-bonded FRP composites
7. American Concrete Institute (ACI). Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures. ACI 440.2R-03, Farmington Hills, Michigan, USA; 2003.
8. Shear strengthening of RC beams with externally bonded FRP composites: effect of strip-width-to-strip-spacing ratio10.1061/(ASCE)CC.1943-5614.0000219 ↗
9. Shear strength of fiber-reinforced polymer reinforced concrete beams subject to unsymmetric loading10.1061/(ASCE)CC.1943-5614.0000184 ↗
10. Maximum shear strength of RC beams retrofitted in shear with FRP composites10.1061/(ASCE)1090-0268(2009)13:4(302) ↗
11. Mechanisms of shear resistance of concrete beams strengthened in shear with externally bonded FRP10.1061/(ASCE)1090-0268(2008)12:5(499) ↗
12. Bae S, Murphy M, Mirmiran A, Belarbi A. Behavior of RC T-beams strengthened in shear with CFRP under cyclic loading. J Bridge Eng– ASCE 2013;18(2):99–109.10.1061/(ASCE)BE.1943-5592.0000332 ↗
13. Flexural reliability of reinforced concrete bridge girders strengthened with carbon fiber-reinforced polymer laminates10.1061/(ASCE)1084-0702(2002)7:5(290) ↗
14. Effect of existing structure and FRP uncertainties on the reliability of FRP-based repair10.1061/(ASCE)CC.1943-5614.0000197 ↗
15. Reliability-based calibration of partial safety coefficients for fiber-reinforced plastic10.1061/(ASCE)1090-0268(2002)6:3(162) ↗
16. Reliability of RC members strengthened with CFRP laminates10.1061/(ASCE)0733-9445(1995)121:7(1037) ↗
17. American Concrete Institute (ACI). Building code requirements for structural concrete. ACI 318-05, Farmington Hills, Michigan, USA; 2005.
18. American Concrete Institute (ACI). Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures. ACI 440.2R-02, Farmington Hills, Michigan, USA; 2002.
19. Nowak · 2000
20. Reliability analysis of nuclear containment without metallic liners against jet aircraft crash10.1016/S0029-5493(03)00080-3 ↗
21. Reliability analysis of buried concrete target under missile impact10.1016/S0734-743X(02)00025-8 ↗
22. Reliability of underground concrete barriers against normal missile impact10.12989/cac.2009.6.1.079 ↗
23. Reliability analysis of TLP tethers under impulsive loading10.1016/j.ress.2004.11.010 ↗