Historical brick-masonry subjected to double flat-jack test: Acoustic emissions and scale effects on cracking density
Source abstract
Abstract
The results obtained varying the size of the masonry prism involved in the double flat-jack test are described. In these tests, not only the deformations have been acquired, but also the acoustic emissions (AE) events, in order to get information about local cracking in the specimens. In addition, a meso-scale numerical model of the test is presented, where every brick of the masonry is modeled in details. Discrete cracks can arise both in the mortar joints and in the brick units. A good correlation is found between the amount of cracking simulated numerically and the experimental AE events for different prism sizes. The model is also able to catch the decrease in the compressive strength with increasing size. Although a quantitative relation between the AE events and the amount of cracking is not easy to obtain, we have been able to prove that the two quantities are simply proportional to each other when increasing specimen sizes are considered, whereas both of them are not proportional to the same sizes, but rather obey a power-law.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Geophysical Methods and Applications · Ultrasonics and Acoustic Wave Propagation · Rock Mechanics and Modeling
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Carpinteri · 1991
2. The effect of heavy persistent actions into the behavior of ancient masonry10.1007/BF02479335 ↗
3. Acito M, Binda L, Cardani G, Guedes JM. Numerical interpretation of the experimental results obtained with flat-jack tests on a brick masonry wall. In: Binda L, di Prisco M, Felicetti R, editors. 1st Int RILEM symp on site assessment of concrete, masonry and timber structures – SACoMaTiS 2008, vol. 2. Varenna (LC), RILEM Publications S.A.R.L.; 2008. p. 693–702 [1–2/09/08].
4. Acito M, Binda L, Cardani G, Guedes J, Miranda L. Experimental and numerical study on the application of the flat jack tests to masonry walls. In: D’Ayala D, Fodde E, editors. VI Int conf on structural analysis of historical constructions (SAHC), vol. 2. Bath, UK; 2008. p. 875–84 [2–4/07/08].10.1201/9781439828229.ch99 ↗
5. Numerical assessment of three medieval towers subjected to different loading conditions
6. ASTM. Standard test method for in situ measurement of masonry deformability properties the using flat-jack method. ASTM C1197-91. Philadelphia; 1991.
7. Structural assessment of a XVIIth century masonry vault with AE and numerical techniques10.1080/15583050701287649 ↗
8. Structural damage diagnosis and life-time assessment by acoustic emission monitoring10.1016/j.engfracmech.2006.01.036 ↗
9. Structural monitoring and integrity assessment of medieval towers10.1061/(ASCE)0733-9445(2006)132:11(1681) ↗
10. Damage monitoring of a masonry building by the acoustic emission technique10.1617/s11527-005-9043-2 ↗
11. Fractal fragmentation theory for shape effects of quasi-brittle materials in compression10.1680/macr.2002.54.6.473 ↗
12. A fractal comminution approach to evaluate the drilling energy dissipation10.1002/nag.209 ↗
13. A multifractal comminution approach for drilling scaling laws10.1016/S0032-5910(02)00335-2 ↗
14. ASTM. Standard test method for in situ compressive stress within solid unit masonry estimated using flat-jack measurements. ASTM C1196-91, Philadelphia; 1991.
15. A review on flat-jack testing
16. Numerical analysis of the flat jack test on masonry walls
17. Acoustic emission. II: acoustic emission amplitudes10.1016/0029-1021(73)90074-1 ↗
18. Acoustic emission. III: the use of ring-down counting10.1016/0029-1021(73)90129-1 ↗
19. The history and development of acoustic emission in concrete engineering10.1680/macr.1996.48.177.321 ↗
20. In situ damage assessment and nonlinear modeling of an historical masonry tower10.1016/j.engstruct.2004.11.001 ↗
21. Holroyd · 2000
22. Rossi PP. Analysis of mechanical characteristics of brick masonry tested by means of in situ tests. In: 6th Int brick/block masonry conf, Rome, Italy; 1982.
23. Flat-jack test as a slightly destructive technique for the diagnosis of brick and stone masonry structures
24. Kaiser J. An investigation into the occurrence of noises in tensile tests, or a study of acoustic phenomena in tensile tests. Ph.D. dissertation, Munich (FRG): Technische Hochschule München; 1950.
25. de Witte · 2007
26. Applications of fractal geometry and renormalization group to the Italian seismic activity10.1016/S0960-0779(02)00081-4 ↗