Experimental study on post-fire performance of half grouted sleeve connection with construction defect
Source abstract
Abstract
Abstract Half grouted sleeve connection (HGSC) is widely used in joining rebars in precast concrete structures. Construction defects and fires are inevitable in practical projects. However, the mechanical behaviors of post-fire HGSC with construction defect remain to be a topic with little research. The present work presents experimental results of 66 post-fire HGSC specimens with construction defect under static tension at room temperatures. Results show that the tensile properties of post-fire HGSC are directly affected by the peak temperature and the construction defect, and some properties are different from that of the rebar. Post-fire HGSC exhibited two main types of failure mode: rebar fracture and bonding failure. The protruded rebar in some post-fire specimens obviously slides before the rebar fractured and the ultimate elongation becomes larger. Different type of construction defect has a different effect on the behavior of the specimens, and the effect depends on the weakening of the effective bond area between rebar and grout. The peak temperature and construction defect may make reliable HGSC be unreliable and not acceptable, once the corresponding peak temperature is near 600 °C. Results also show that the proposed method to simulate the construction defects of HGSC is feasible and the X-ray method is an effective way to detect the defects in HGSC.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Fire effects on concrete materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. JGJ1-2014, Technical specification for precast concrete structures, Ministry of Housing and Urban-Rural Development of China, Beijing, 2014.
2. Tensile behavior of half grouted sleeve connection at elevated temperatures10.1016/j.conbuildmat.2018.05.027 ↗
3. Grouted pile-to-sleeve connection tests
4. Grout-filled pipe splices for precast concrete construction10.15554/pcij.01011995.82.93 ↗
5. Goh · 2009
6. Experimental research on effects of grout age and types of steel bars on mechanical behavior of grout sleeve splicing for reinforcing bars
7. Kim · 2000
8. Experimental study on connection performance of grouted sleeve splicing for rebars under high stress repeated tension-compression loading
9. Behavior of grouted sleeve connections at elevated temperatures10.1016/j.tws.2006.07.002 ↗
10. Mechanical behavior of post-fire half grouted sleeve connection covered by concrete10.1016/j.conbuildmat.2018.12.184 ↗
11. The relationship between interlocking mechanism and bond strength in elastic and inelastic segment of splice sleeve10.1016/j.conbuildmat.2014.01.020 ↗
12. Behaviour of grouted pipe splice under incremental tensile load10.1016/j.conbuildmat.2012.02.001 ↗
13. Feasibility study of grouted splice connector under incremental tensile load10.1016/j.conbuildmat.2013.10.010 ↗
14. Tensile capacity of grouted splice sleeves10.1016/j.engstruct.2015.12.023 ↗
15. Experimental study and finite element analysis on behavior of deformed grouted-filled pipe splice
16. Tensile behavior of half grouted sleeve connections: experimental study and analytical modeling10.1016/j.conbuildmat.2017.06.154 ↗
17. Experimental study on effects of grout defects on the connection behaviors of grout sleeve splicing for reinforcing bars
18. Wang · 2017
19. Experimental study on effects of grout defects on seismic performance of assembled concrete columns
20. Experimental study on the effects of grout defect on the strength of grout sleeve splicing for reinforcing bars
21. Experimental bond behavior of deformed rebars in half-grouted sleeve connections with insufficient grouting defect10.1016/j.conbuildmat.2018.07.050 ↗
22. American Concrete Institute Committee 318, Building Code Requirements for Structural Concrete (ACI 318-14), American Concrete Institute (Editor), Farmington Hills, Michigan, 2014.
23. JGJ 355-2015, Technical specification for grout sleeve splicing of rebars, Ministry of Housing and Urban-Rural Development of China, Beijing, 2015.
24. GB/T 17671-1999 idt ISO 679:1989, Method of testing cements - Determination of strength, General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Beijing, 1999.
25. JG/T 408-2013, Cementitious grout for coupler of rebar splicing, Ministry of Housing and Urban-Rural Development of China, Beijing, 2013.
26. GB 50010-2010, Code for design of concrete structures, Ministry of Housing and Urban-Rural Development of China, Beijing, 2010.
27. GB/T 228.1-2010 eqv. ISO 6892-1:2009, MOD Metallic materials - Tensile testing - Part 1: Method of test at room temperature General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, and Standardization Administration of the People's Republic of China, Beijing, 2002.
28. JGT 398-2012, The grouting coupler for rebars splicing, Ministry of Housing and Urban-Rural Development of China, Beijing, 2012.
29. Ultrasonic testing method of grouting sleeve compactness
30. GB/T 196-2003 eqv. ISO 724:1993, MOD General purpose metric screw threads - Basic dimensions, General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Beijing, 2003.
31. JGJ 107-2010, Technical specification for mechanical splicing of steel reinforcing bars, Ministry of Housing and Urban-Rural Development of China, Beijing, 2010.
32. ACI 318-14, Building code requirements for structural concrete, American Concrete Institute Committee, Farmington Hills, Michigan, 2014.