journal article·2021-03

Corrosion initiation mechanisms and service life estimation of concrete systems with fusion-bonded-epoxy (FBE) coated steel exposed to chlorides

Deepak K. Kamde, Radhakrishna G. Pillai

Publisher page

Abstract

Abstract This paper evaluates the suitability of various techniques such as half-cell potential, macrocell corrosion, linear polarization resistance, and electrochemical impedance spectroscopy (EIS) to detect corrosion initiation of fusion-bonded-epoxy (FBE) coated steel rebars in concrete. It was found that EIS is the best technique for this purpose. Then, a new test method (named as “cs-ACT” test) using EIS is developed to detect the initiation of corrosion and determine chloride threshold at the coating-steel interface, which was not a practice in the literature. Also, the reduction in the resistance of the FBE coating was monitored and a a 4-stage degradation process and corrosion initiation process are identified and discussed using SEM, EDAX, and statistical analysis of the change in the polarization resistance of steel (from repeated EIS tests - Nyquist/Bode plots). Then, a new method that uses the properties of epoxy coating, steel-coating interface, and concrete cover to estimate the service life of reinforced concrete systems with FBE coated rebars is demonstrated. Modifications to the existing specifications to achieve target service life are also proposed.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Infrastructure Maintenance and Monitoring

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (80)

Show source-provided references
1. Protective properties of epoxy-based organic coatings on mild steel10.1016/0033-0655(93)80050-K ↗
2. McDonald · 2009
3. A. Griffith, H.M. Laylor, Epoxy Coated Reinforcement Study, Oregon, 1999.
4. W.A. Pyć, R.E. Weyers, M. Weyers, D.W. Mokarem, J. Zemajtis, Field performance of epoxy-coated reinforcing steel in virginia bridge decks, Virginia Department of Transportation, Charlottesville, Virginia, 2000.
5. An evaluation of the performance of epoxy-coated reinforcing steel in concrete exposure specimens
6. G.R. Kim, S.H. Lee, H.Y. Song, J.M. Han, Electrochemical characterization of epoxy coated steel under cathodic protection, in: NACE Corros. Conf. Expo, 2007: pp. 1–13.10.5006/C2007-07013 ↗
7. Performance of coated reinforcing bars in cracked bridge decks10.1061/(ASCE)1084-0702(2005)10:3(255) ↗
8. The performance of epoxy coated reinforcement : experience of the Ontario ministry of transportation10.1504/IJMPT.2005.007732 ↗
9. Corrosion of epoxy-coated rebar in marine bridges – a 30 year perspective10.5006/1.3452397 ↗
10. A.A. Sagues, R.G. Powers, Effect of Concrete Environment on the Corrosion Performance of Epoxy-Coated Reinforcing Steel, Corrosion/90. Paper No. (1990).10.5006/C1990-90311 ↗
11. K.Z. Kahhaleh, E. Vaca-cortés, J.O. Jirsa, H.G. Wheat, R.L. Carrasquillo, Corrosion performance of epoxy-coated reinforcement – macrocell tests, Texas, USA, 1998.
12. Epoxy coated rebars the panacea for steel corrosion in concrete10.1016/S0950-0618(89)80006-6 ↗
13. Macrocell corrosion studies of coated rebars10.1007/s13369-014-1006-x ↗
14. Long-term outdoor exposure evaluation of concrete slabs containing epoxy-coated reinforcing steel
15. Effect of prior damage on the performance of cement based coatings on rebar: Macrocell corrosion studies10.1016/S0958-9465(00)00041-X ↗
16. A.A. Sohanghpurwala, K.C. CLEAR, Effectiveness of Epoxy Coatings in Minimizing Corrosion of Reinforcing Steel in Concrete, (1990) 193–204.
17. Corrosion performance of epoxy-coated reinforcing steel: North American experience10.1016/0950-0618(95)00028-3 ↗
18. C.M. Hansson, R. Haas, R. Green, R.C. Evers, O.K. Gepraegs, R. Al-Assar, Corrosion Protection Strategies for Ministry Bridges, 2000.
19. Defects in epoxy-coated reinforcement and their impact on the service life of a concrete structure A study of critical chloride content and macro-cell corrosion10.1002/suco.201400085 ↗
20. Epoxy-coated reinforcement in concrete structures: results of a Swiss pilot project after 24 years of field exposure10.1002/maco.201608863 ↗
21. E.V. Cortés, Corrosion Performance of Epoxy-Coated Reinforcement in Aggressive Environments, The University of Texas at Austin, 1998.
22. Long-term performance of fusion-bonded epoxy-coated steel bars in chloride-contaminated concrete
23. Coating condition evaluation of epoxy-coated rebar
24. Service life extension of virginia bridge decks afforded by epoxy-coated reinforcement10.1520/JAI11793 ↗
25. Goffin · 2017
26. ASTM C876, Astm C876: Standard Test Method for Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete, 2015. doi: 10.1520/C0876-09.2.
27. Reliability evaluation of half-cell potential measurement using POD10.1061/(ASCE)IS.1943-555X.0000334 ↗
28. Half-cell potential measurements - Potential mapping on reinforced concrete structures10.1007/BF02481526 ↗
29. S. Kessler, C. Gehlen, Influence of Concrete Moisture Condition on Half-Cell Potential Measurement, Int. Conf. Durab. Concr. Struct. ICDCS 2016. 5th Intern (2016) 257–264. doi: 10.5703/1288284316142.10.5703/1288284316142 ↗
30. Unexpected deterioration of fusion-bonded epoxy-coated rebars embedded in chloride-contaminated concrete environments10.5006/1.3278216 ↗
31. ASTM G109-07, Standard Test Method for Determining the Effects of Chemical Admixtures on the Corrosion of Embedded Steel Reinforcement in Concrete Exposed to Chloride Environments, West Conshohocken, USA, 2013. doi: 10.1520/G0109-07R13.2.
32. Macrocell corrosion mechanisms of prestressing strands in various concretes10.1680/jmacr.18.00284 ↗
33. Macrocell and microcell corrosion of steel in ordinary Portland cement and high performance concretes10.1016/j.cemconres.2006.07.005 ↗
34. Corrosion behavior of epoxy-coated reinforced bars in RC test specimens subjected to pre-exposure loading and wetting-drying cycles10.1016/j.conbuildmat.2016.05.066 ↗
35. S.K. Lee, P.D. Krauss, Long-Term Performance of Epoxy-Coated Reinforcing Steel in Heavy Salt-Contaminated Concrete, FHWA-HRT-0 (2004).
36. Corrosion measurements in concrete structures and interpretation of data
37. Investigation on the polarization resistance of steel embedded in highly resistive cementitious systems e An attempt and challenges10.1016/j.electacta.2019.03.200 ↗
38. W.S. Tait, Corrosion Prevention and Control of Chemical Processing Equipment, in: Handb. Environ. Degrad. Mater. Second Ed., Second Edi, Elsevier Inc., 2012: pp. 863–886. doi: 10.1016/B978-1-4377-3455-3.00028-6.10.1016/B978-1-4377-3455-3.00028-6 ↗
39. Coatings Ingress of water into organic coatings : Real-time monitoring of the capacitance and increase in mass10.1016/j.porgcoat.2010.04.004 ↗
40. M.G. Fontana, Corrosion Engineering, 3rd ed., McGraw-Hill Book Company, Singapore, 1986.
41. Water uptake in protective organic coatings and its re fl ection in measured coating impedance10.1016/j.porgcoat.2018.03.002 ↗
42. Electrochemical impedance spectroscopy for in situ petroleum analysis and water-in-oil emulsion characterization10.1016/j.fuel.2011.06.057 ↗
43. Electrochemical corrosion of a noble metal-bearing alloy-oxide composite10.1016/j.corsci.2017.04.010 ↗
44. Low-frequency electrochemical impedance for measuring corrosion of epoxy-coated reinforcing steel in concrete10.5006/1.3585197 ↗
45. Impact and corrosion resistances of duplex epoxy/enamel coated plates10.1016/j.conbuildmat.2016.02.170 ↗
46. Cement-modified enamel coating for enhanced corrosion resistance of steel reinforcing bars10.1016/j.cemconcomp.2012.08.009 ↗
47. F. Tang, G. Chen, R.K. Brow, M.L. Koenigstein, Electrochemical Characteristics and Equivalent Circuit Representation of Mortar-Coating-Steel Systems by EIS, in: Corros. Conf., 2014: pp. 1–10.10.5006/C2014-4090 ↗
48. Corrosion resistance and mechanism of steel rebar coated with three types of enamel10.1016/j.corsci.2012.02.024 ↗
49. Electrochemical and physico-chemical characterization of fluorinated organic coatings for steel and concrete protection: Influence of the pigment volume concentration10.1016/S0300-9440(98)00049-6 ↗
50. Low-frequency electrochemical impedance for measuring corrosion of epoxy-coated reinforcing steel in concrete*10.5006/1.3585197 ↗
51. Electrochemical behavior of mild and corrosion resistant concrete reinforcing steels10.1016/j.conbuildmat.2019.117205 ↗
52. K. Tuutti, Service life of structures with regard to corrosion of embedded steel, (n.d.).
53. Service life and life cycle assessment of reinforced concrete systems with limestone calcined clay cement (LC3)10.1016/j.cemconres.2018.11.019 ↗
54. Use of supplementary cementitious materials (SCMs) in reinforced concrete systems – Benefits and limitations10.21041/ra.v10i2.477 ↗
55. Some issues related to service life of concrete structures
56. Accelerated chloride threshold testing: Part I - ASTM A 615 and A 706 reinforcement
57. Propagation of reinforcement corrosion: principles, testing and modelling10.1617/s11527-018-1301-1 ↗
58. D.K. Kamde, R.G. Pillai, Effect of sunlight/ultraviolet exposure on the corrosion of fusion bonded-epoxy (FBE) coated steel rebars in concrete, Corros. 76 (2020) 843–860. doi: 10.5006/3588.10.5006/3588 ↗
59. D.K. Kamde, M. Zintel, S. Kessler, G.P. Radhakrishna, Performance indicators and specifications for fusion-bonded-epoxy (FBE) coated steel rebars in concrete exposed to chlorides, J. Sustain. Resilient Infrastruct. In press (2020). doi: 10.1080/23789689.2020.1871539.10.1080/23789689.2020.1871539 ↗
60. Multiple corrosion-protection systems for reinforced-concrete bridge components: laboratory tests10.1061/(ASCE)MT.1943-5533.0000991 ↗
61. Trejo · 2020
62. The steel – concrete interface10.1617/s11527-017-1010-1 ↗
63. Effect of surface preparation on corrosion of steel rebars coated with cement-polymer-composites (CPC) and embedded in concrete10.1016/j.conbuildmat.2019.117616 ↗
64. D. Kamde, Electrochemical, bond, and service life parameters of coated steel – cementitious systems exposed to chlorides, Ph.D. Thesis, Indian Institute of Technology Madras, 2020.
65. A short-term test method to determine the chloride threshold of steel – cementitious systems with corrosion inhibiting admixtures10.1617/s11527-017-1071-1 ↗
66. Moisture absorption and the influence of moisture on the dielectric properties of glass fiber reinforced plastics
67. SHRP-S-330, Standard Test Method for Chloride Content in Concrete Using the Specific Ion Probe, (1993) 1–118.
68. S. Rengaraju, Electrochemical Response and Chloride Threshold of Steel in Highly Resistive Concrete Systems, Indian Institute of Technology Madras, 2019.
69. Corrosion performance of epoxy-coated bars in four bridge decks subjected to deicing salts: 30-year perspective10.1061/(ASCE)CF.1943-5509.0000592 ↗
70. S. Kessler, K. Lau, W.F. Street, A.A. Sagüés, Extent of Cathodic Reaction on Epoxy Coated Rebar with Partially Disbonded Coating, in: NACE Corros. Conf. Expo, NACE International, Houston, Texas, 2017: pp. 1–12.10.5006/C2017-09469 ↗
71. Performance of fusion-bonded epoxy-coated steel reinforcement
72. Retarding of corrosion processes on reinforcement bar in concrete with an FBE coating10.1016/S0958-9465(01)00028-2 ↗
73. Errors in the electrochemical evaluation of very small corrosion rates-I. polarization resistance method applied to corrosion of steel in concrete10.1016/0010-938X(85)90021-6 ↗
74. Influence of external loading and loading type on corrosion behavior of RC beams with epoxy-coated reinforcements10.1016/j.conbuildmat.2015.05.101 ↗
75. Technical Note: Equivalent circuits representing the impedance of a corroding interface10.5006/1.3583975 ↗
76. Corrosion protection of electrically conductive surfaces10.3390/met2040450 ↗
77. Effects of surface morphology and treatment of iron oxide nanoparticles on the mechanical properties of an epoxy coating10.1016/j.porgcoat.2015.09.018 ↗
78. Experimental studies on epoxy coated reinforcing steel for corrosion protection10.1016/0262-5075(84)90039-3 ↗
79. Effect of epoxy coating thickness on bond strength of reinforcing bars
80. IS 13620, IS 13620: Fusion bonded epoxy coated reinforcing bars-specification, Bur. Indian Stand. 1993 (2015).