Axial compressive performance of CFRP confined rectangular CFST columns using high-strength materials with moderate slenderness
Source abstract
Abstract
Abstract The bearing capacity of concrete-filled steel tube (CFST) columns can be significantly increased by using high-strength materials. However, the ductility of high-strength CFST columns is reduced due to the brittleness of high-strength concrete and the buckling of thin-walled high-strength steel tubes, especially for slender columns. By wrapping the carbon fiber reinforced polymer (CFRP) to increase the confinement on the steel tube, the ductility can be improved. This paper presents experimental and theoretical studies on the axial compressive performance of CFRP confined rectangular CFST columns using high-strength steel and concrete with moderate slenderness. The influence of the section aspect ratio, concrete strength, and CFRP confinement on the axial behavior was analyzed. The experimental results indicate that the local buckling of CFRP-confined specimens is delayed compared with the unconfined specimens. The horizontal CFRP confinement increases the yield load by 1.5–25.6%, and the peak load by 2.5–11.2%. The bearing capacity and ductility of specimens are improved under the confinement of CFRP. The calculation method for axial compression bearing capacity considering the stability of moderate slender specimens was proposed. The ratio of the experimental results to the calculated value is between 0.86 and 1.09, which verified the accuracy of the calculation method.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Structural Engineering and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Concrete-Filled Steel Tubes Subjected to Axial Compression and Lateral Cyclic Loads10.1061/(ASCE)0733-9445(2004)130:4(631) ↗
2. Strength of Concrete-Filled Thin-Walled Steel Box Columns: Experiment10.1061/(ASCE)0733-9445(1992)118:11(3036) ↗
3. Fire resistance of concrete-filled high strength steel tubular columns10.1016/j.tws.2013.05.005 ↗
4. Strength of short concrete filled high strength steel box columns10.1016/S0143-974X(00)00014-6 ↗
5. Ultimate capacity of high-strength rectangular concrete-filled steel hollow section stub columns10.1016/S0143-974X(03)00106-8 ↗
6. Axial load behaviour of high-strength rectangular concrete-filled steel tubular stub columns10.1016/j.tws.2005.03.007 ↗
7. Experimental research on lamellar tearing of concrete-filled steel tubular structure joints of middle thickness plates
8. Rectangular concrete-filled steel tubular beam-columns using high-strength steel: Experiments and design10.1016/j.jcsr.2016.12.016 ↗
9. Ultimate resistance behavior of rectangular concrete-filled tubular beam-columns made of high-strength steel10.1016/j.jcsr.2017.02.024 ↗
10. Behavior of rectangular concrete-filled high-strength steel tubular columns with different aspect ratio10.1016/j.tws.2016.10.005 ↗
11. Experimental behavior and design method of rectangular concrete-filled tubular columns using Q460 high-strength steel10.1016/j.conbuildmat.2016.08.057 ↗
12. Slenderness effects on concrete-filled steel tube columns confined with CFRP10.1016/j.jcsr.2017.12.014 ↗
13. Cyclic performance of fire-damaged concrete-filled steel tubular beam-columns repaired with CFRP wraps10.1016/j.jcsr.2007.02.004 ↗
14. Design-oriented stress–strain model for FRP-confined concrete10.1016/S0950-0618(03)00045-X ↗
15. A review of the present and future utilisation of FRP composites in the civil infrastructure with reference to their important in-service properties10.1016/j.conbuildmat.2010.04.062 ↗
16. Experimental and theoretical studies of FRP-Steel composite plate under static tensile loading
17. A review on steel/CFRP strengthening systems focusing environmental performance10.1016/j.conbuildmat.2013.04.049 ↗
18. Confined Concrete-Filled Tubular Columns10.1061/(ASCE)0733-9445(2005)131:3(488) ↗
19. Behavior of Circular CFRP-Steel Composite Tubed High-Strength Concrete Columns under Axial Compression10.1016/j.compstruct.2019.01.011 ↗
20. Axial load behavior of square CFT stub column with binding bars10.1016/j.jcsr.2005.09.010 ↗
21. Compressive behavior of CFRP-confined post heated square CFST stub columns10.1016/j.tws.2018.02.012 ↗
22. Axial Loading Behavior of CFRP Strengthened Concrete-Filled Steel Tubular Stub Columns10.1260/136943307780150814 ↗
23. Static behavior of axially compressed square concrete filled CFRP-steel tubular (S-CF-CFRP-ST) columns with moderate slenderness10.1016/j.tws.2016.10.019 ↗
24. Metallic Materials-Tensile Testing-Part 1: Methods of test at room temperature, Standardization Administration of China, China, 2010.
25. Standard for test methods of concrete physical and mechanical properties, Standardization Administration of China, China, 2019.
26. Fiber-reinforced plastics composites—Determination of tensile properties, Standardization Administration of China, China, 2005.
27. Technical code for concrete filled steel tubular structures, Standardization Administration of China, China, 2014.
28. Experimental study and numerical analysis on seismic performance of FRP confined high-strength rectangular concrete-filled steel tube columns10.1016/j.tws.2021.107560 ↗
29. Elastic local buckling of steel plates in composite steel-concrete members10.1016/0141-0296(95)00143-3 ↗
30. Local and post-local buckling of concrete filled steel welded box columns10.1016/S0143-974X(98)80102-8 ↗
31. Behavior of square hollow steel tubes and steel tubes filled with concrete10.1016/j.tws.2007.07.009 ↗
32. Architectural Institute of Japan (AIJ), Japan · 2008
33. Richart · 1928
34. Unified Strength Model for Square and Circular Concrete Columns Confined by External Jacket10.1061/(ASCE)0733-9445(2009)135:3(253) ↗