Shear behavior of continuous reinforced concrete T-beams using wire rope as internal shear reinforcement
Source abstract
Abstract
Abstract The use of wire ropes with high-strength and high flexibility as internal shear reinforcement can solve the difficulties encountered in bending higher strength steel bar and can provide a better shear behavior to concrete beams. Three two-span reinforced concrete T-beams were tested to failure in order to examine the possibility of the practical application of wire ropes as shear reinforcement. The measured shear capacities of beams were compared with predictions obtained from equations specified in ACI 318-08 and the mechanism analysis based on the upper-bound theorem of concrete plasticity. Test results showed that using spiral-type wire rope as shear reinforcement is highly favourable for controlling the diagonal crack width and enhancing the ductility of beams failing in shear. In particular, the high-strength of the wire ropes significantly promoted the shear capacity of concrete beams. When a limit stress of 420 MPa for wire ropes is employed, ACI 318-08 is highly conservative in beams with spiral-type wire ropes compared with the control beams with closed stirrups. In addition, ACI 318-08 is still conservative when using the equivalent yield strength of wire ropes. On the other hand, the predictions obtained from the mechanism analysis are in good agreement with test results, regardless of the type of shear reinforcement.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Mechanical stress and fatigue analysis · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Park R, Paulay T. Reinforced concrete structures. John Wiley & Sons; 1975.10.1002/9780470172834 ↗
2. MacGregor JG, Wight JK. Reinforced concrete: mechanics and design. Prentice Hall; 2005.
3. ACI-ASCE Committee 426. The shear strength of reinforced concrete members. J Struct Div-ASCE 1973; 99(ST6): 1091–187.10.1061/JSDEAG.0003532 ↗
4. Comparative study of behavior of reinforced concrete beams strengthened and repaired-strengthened by using V connecting bars and U connecting stirrups10.1016/S0950-0618(02)00031-4 ↗
5. ACI Committee 318. Building code requirements for structural concrete (ACI 318-08) and commentary (ACI 318R-08). American Concrete Institute; 2008.
6. Behavior of high-performance steel as shear reinforcement for concrete beams
7. Ductility of high-performance concrete beams with high-strength lateral reinforcement
8. High-strength steel as shear reinforcement in prestressed concrete beams
9. Tests to determine performance of deformed welded-wire fabric stirrups
10. Seismic design of columns with high-strength wire and strand as spiral reinforcement
11. Shear strengthening of continuous reinforced concrete T-beams using wire rope units10.1016/j.engstruct.2009.01.003 ↗
12. Experimental study on the effect of flange geometry on the shear strength of reinforced concrete T-beams subjected to concentrated loads10.1139/l02-099 ↗
13. ASTM A 416. Standard specification for steel strand, uncoated seven-wire for prestressed concrete. American Society for Testing and Materials; 1996.
14. Analysis of large diameter steel popes10.1061/(ASCE)0733-9399(1995)121:6(667) ↗
15. ACI-ASCE Committee 441. High-strength concrete columns: state of the art. ACI Struct J 1997; 94(3): 323–35.10.14359/484 ↗
16. Effectiveness factor of concrete in continuous deep beams10.1061/(ASCE)0733-9445(1996)122:2(169) ↗
17. Application of plasticity theory to reinforced concrete deep beams—a review10.1680/macr.2008.00038 ↗
18. Diagonal cracking and shear strength of reinforced concrete beams10.1680/macr.1997.49.178.55 ↗