journal article·2015-05

Strengthening of adobe houses with arch roofs using tie-bars and polypropylene band mesh

Navaratnarajah Sathiparan, Kimiro Meguro

Publisher page

Abstract

Abstract The purpose of this study was to compare the effects of strengthening adobe houses with an arch roof using polypropylene band (PP-band) mesh with or without tie-bars. To this end, an experimental analysis was conducted on scale models of adobe houses. In one test, an arch roof was retrofitted with only a PP-band mesh. In the second test, in addition to being retrofitted with PP-band mesh, tie-bars were used for horizontal support at roof level. These two PP-band retrofitted house models and house model with tie-bars only were subjected to sinusoid loading until the point of collapse or the capacity of the shaking table was exceeded. Results collected during the analyses were significant in assessing the capability of these retrofitting methods to support dynamic loads, increasing the collapse load, stiffness and ductility and dissipate energy.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Hygrothermal properties of building materials · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Strengthening of masonry arches with fiber-reinforced polymer strips10.1061/(ASCE)1090-0268(2004)8:3(191) ↗
2. Japan Bank for International Cooperation (JBIC), International Center for Urban Safety Engineering, OYO International Corporation. Pilot studies for knowledge assistance for verification and promotion on a new seismic retrofitting method for existing masonry houses by polypropylene band mesh (The Islamic Republic of IRAN). Institute of Industrial Science, Tokyo; 2007.
3. Some aspects of testing small-scale masonry building models on simple earthquake simulators10.1002/eqe.4290211102 ↗
4. Shaking table tests of an arch-pillars system and design of strengthening by the use of tie-rods10.1007/s10518-014-9678-x ↗
5. Experimental behavior of FRP strengthened masonry arches10.1061/(ASCE)CC.1943-5614.0000086 ↗
6. Behavior of brick masonry walls strengthened by FRP laminates10.1061/(ASCE)1090-0268(2001)5:3(163) ↗
7. Towards a methodology for estimating strength and collapse mechanism in masonry arches strengthened with fibre reinforced polymer applied on external surfaces10.1617/s11527-007-9328-8 ↗
8. Experimental tests and numerical modeling of reinforced masonry arches10.1016/j.engstruct.2009.12.005 ↗
9. Simulations and analyses of arched brick structures10.1016/j.autcon.2011.01.005 ↗
10. Rehabilitation of masonry arches with compatible advanced composite material10.1016/j.conbuildmat.2011.03.065 ↗
11. Behaviour of a masonry arch bridge repaired using fibre-reinforced polymer composites10.1016/j.engstruct.2011.01.029 ↗
12. Textile-reinforced mortar as strengthening material for masonry arches10.1080/15583058.2012.704480 ↗
13. Flexural displacement response of NSM FRP retrofitted masonry walls10.1016/j.conbuildmat.2012.06.065 ↗
14. Out-of-plane strengthening of unreinforced masonry walls using near surface mounted fibre reinforced polymer strips10.1016/j.engstruct.2013.10.026 ↗
15. In-plane shear improvement of unreinforced masonry wall panels using NSM CFRP strips10.1061/(ASCE)CC.1943-5614.0000400 ↗
16. Strengthening of brick masonry arches with externally bonded steel reinforced composites10.1061/(ASCE)CC.1943-5614.0000030 ↗
17. Bond behavior of historical clay bricks strengthened with steel reinforced polymers (SRP)10.3390/ma4030585 ↗
18. Boughton BW, Falconer RE, Sumon S. Masonry arch repairs and strengthening. In: Bridge Modification 2: Stronger and Safer Bridges, London, UK; 1997: 122–130, ISBN: 07277 2589 0: pp. 122–130.
19. Seismic evaluation of earthquake resistance and retrofitting measures for two story masonry houses10.1007/s10518-014-9587-z ↗
20. Shake table tests on one-quarter scale models of masonry houses retrofitted with PP-band mesh10.1193/1.3675357 ↗
21. Shear and flexural bending strength of masonry wall retrofitted using PP-band mesh
22. Experimental investigation on the seismic performance of PP-band strengthening stone masonry houses10.1007/s10518-013-9502-z ↗
23. Formulation of a simple method to design PP-band mesh retrofitting for adobe/masonry houses
24. Lourenco PB. Computational strategies for masonry structures. [Ph.D. theses], Delft: Delft University of Technology; 1996.
25. Proposal of instrumental seismic intensity scale from response spectra in various period ranges10.3130/aijs.69.71_4 ↗
26. 2001
27. Benjamin JR (ed). A criterion for determining exceedance of the operating basis earthquake, Report No. EPRI NP-5930, Palo Alto, California: Electrical Power Research Institute; 1988.
28. Behavior of fully grouted reinforced concrete masonry shear walls failing in flexure: analysis10.1016/j.engstruct.2009.03.006 ↗
29. Static cyclic response of masonry walls retrofitted with fiber reinforced polymer10.1061/(ASCE)1090-0268(2007)11:1(50) ↗