Numerical analysis of behaviour of concrete beams with external FRP tendons
Source abstract
Abstract
Abstract The use of FRP (fibre reinforced polymer) composites as external prestressing tendons is expected to be popular. A numerical investigation is conducted to evaluate the short-term behaviour of external FRP tendon beams, and the results are compared with those of external steel tendon beams. The analysis shows that beams prestressed with external CFRP and steel tendons exhibit similar behaviour, and that external GFRP tendon beams have lower flexural strengths but better ductility behaviour than do external steel tendon beams. The type of external tendons has no important effect on the redistribution of moments in continuous beams. The amount of prestressing reinforcement significantly affects the member behaviour, including cracking and ultimate loads, ductility, neutral axis depth and reinforcement stress. The crack pattern is greatly improved by providing a minimum amount of bonded reinforcement. The analysis also indicates that the ultimate load decreases linearly with increasing deviator spacing, provided that failure happens at midspan. A method for determining the optimum deviator spacing is proposed.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Bang Na expressway, Bangkok, Thailand—world’s longest bridge and largest precasting operation10.15554/pcij.01012000.26.38 ↗
2. Nordin H. Strengthening structures with externally prestressed tendons. Technical Report, Lulea University of Technology, Lulea, Sweden; 2005.
3. Flexural response of concrete beams prestressed with AFRP tendons: numerical investigation10.1061/(ASCE)CC.1943-5614.0000128 ↗
4. Testing of full-scale concrete bridge deck slabs reinforced with fiber-reinforced polymer (FRP) bars10.1016/j.conbuildmat.2011.04.028 ↗
5. Ductility characteristics of fiber-reinforced-concrete beams reinforced with FRP rebars10.1016/j.conbuildmat.2010.11.040 ↗
6. Externally prestressed members: evaluation of second-order effects10.1061/(ASCE)0733-9445(1999)125:10(1151) ↗
7. Geometrical nonlinearity and length of external tendons10.1061/(ASCE)1084-0702(2005)10:3(302) ↗
8. Numerical analysis of second-order effects of externally prestressed concrete beams10.12989/sem.2010.35.5.631 ↗
9. Factors affecting the external prestressing stress in externally strengthened prestressed concrete beams10.1016/j.cemconcomp.2005.05.003 ↗
10. Behaviour of partially prestressed beams with external tendons10.1680/macr.2008.60.6.455 ↗
11. Externally post-tensioned carbon FRP bar system for deflection control10.1016/j.conbuildmat.2007.08.002 ↗
12. Finite element modeling of concrete beams prestressed with external tendons10.1016/j.engstruct.2006.03.020 ↗
13. Hognestad E. A study of combined bending and axial load in reinforced concrete members. Bulletin No. 399. Urbana (IL, USA): University of Illinois Engineering Experiment Station; 1951.
14. Menegotto M, Pinto PE. Method of analysis for cyclically loaded reinforced concrete plane frames. IABSE preliminary report for symposium on resistance and ultimate deformability of structures acted on well-defined repeated loads, Lisbon; 1973. p 15–22.
15. Prediction of tendon stress and flexural strength of externally prestressed concrete beams
16. Flexural response of continuous concrete beams prestressed with external tendons
17. A numerical survey on the behaviour of beams pre-stressed with FRP cables10.1016/S0950-0618(97)00081-0 ↗
18. American Concrete Institute (ACI) Committee 318. Building code requirements for structural concrete (ACI 318–08) and commentary (ACI 318R–08). Farmington Hills, MI. ACI; 2008.