Experimental study of the bond performance and mechanical response of GFRP reinforced concrete
Source abstract
Abstract
Abstract This study carried out laboratory investigations of mechanical behaviors of glass fiber reinforced polymer (GFRP) concrete and consisted of three test programs. It first obtained elastic parameters of GFRP bar and then conducted pull-out test to evaluate the bond performance of GFRP/steel bar with concrete. The test variables involved diameter, thread depth, thread width, embedment length of GFRP bar and cement strength, a total of 32 combinations. Test results indicate the optimum GFRP bar is with thread gap of 0.8-diameter, thread depth of 1 mm, and in favor of small diameter size. The GFRP reinforced specimens provide approximately 60% of bond strength benchmarked by the steel reinforced specimens but have much higher slip length. Lastly, four-point bending test was applied to five types of GFRP/steel reinforced concrete beams to investigate the mechanical responses of the beams until failure. Test results indicate at the same reinforcement ratio and geometric size, GFRP bar and steel bar have the same bearing capacities. However, the former is inferior to the latter in terms of crack control.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Continuous concrete beams reinforced with CFRP bars10.1680/stbu.2008.161.6.349 ↗
2. Bond degradation of basalt fiber-reinforced polymer (BFRP) bars exposed to accelerated aging conditions10.1016/j.conbuildmat.2015.02.036 ↗
3. Analytical and experimental flexural behavior of concrete beams reinforced with glass fiber reinforced polymers bars10.1016/j.conbuildmat.2015.03.057 ↗
4. Deflection behaviour of FRP reinforced concrete beams and slabs: an experimental investigation10.1016/j.compositesb.2012.03.007 ↗
5. Tensile properties degradation of glass fiber-reinforced polymer bars embedded in concrete under severe laboratory and field environmental conditions10.1177/0021998312440473 ↗
6. American Concrete Institute (ACI) Committee 440 · 2004
7. Experimental study of bond behavior between concrete and FRP bars using a pull-out test10.1016/j.compositesb.2009.07.003 ↗
8. An experimental study of the flexural behaviour of GFRP RC beams and comparison with prediction models10.1016/j.compstruct.2009.05.005 ↗
9. Long-term bending performance and service life prediction of pultruded Glass Fibre Reinforced Polymer composites10.1016/j.compstruct.2015.03.049 ↗
10. Fibres for enhancing of the bond capacity between GFRP rebar and concrete10.1016/j.conbuildmat.2013.10.089 ↗
11. Experimental study of immediate and time dependent deflections of GFRP reinforced concrete beams10.1016/j.compstruct.2012.08.052 ↗
12. Behavior of GFRP reinforcing bars subjected to extreme temperatures10.1061/(ASCE)CC.1943-5614.0000092 ↗
13. Effective moment of inertia prediction of FRP-reinforced concrete beams based on experimental results10.1061/(ASCE)CC.1943-5614.0000284 ↗
14. Thermo-mechanical loading of GFRP reinforced thin concrete panels10.1016/j.compositesb.2015.06.020 ↗
15. Influence of reinforcement on the behavior of concrete bridge deck slabs reinforced with FRP bars10.1061/(ASCE)1090-0268(2007)11:5(449) ↗
16. Static and fatigue bond characteristics of FRP rebars embedded in fibre-reinforced concrete10.1177/0021998309355845 ↗
17. Local bond-slip response of GFRP rebar in ultra-high-performance fiber-reinforced concrete10.1016/j.compstruct.2014.09.055 ↗
18. Durability and service life prediction of GFRP bars embedded in concrete under acid environment10.1016/j.nucengdes.2011.08.038 ↗