journal article·2016-09Open access

Pre-diagnostic prompt investigation and static monitoring of a historic bell-tower

Antonella Saisi, Carmelo Gentile, Antonello Ruccolo

Abstract

Abstract An extensive research program is currently in progress to assess the structural condition of the bell-tower of the Church Santa Maria del Carrobiolo in Monza, Italy and to address the preservation of the historic building. The research program was consequent to the direct survey of the tower, carried out within a wide cataloguing activity of the main religious buildings in Monza and highlighting a weak structural layout of the bell-tower. The paper presents the main results of the investigation program performed to date and including: (a) documentary research, systematic visual inspection on site and experimental evaluation of the fundamental period of the tower, carried out using an industrially engineered microwave interferometer; (b) installation of a static monitoring system aimed at surveying the opening of the main cracks, possibly related to the recent construction of an underground car park in the close neighbourhood of the church; (c) dynamic tests in operational conditions, performed using conventional high-sensitivity accelerometers with the twofold objective of validating a FE model of the tower and implementing the installation of a continuous dynamic monitoring system.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Health Monitoring Techniques · Seismic Performance and Analysis · Structural Engineering and Vibration Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Italian Ministry of Cultural Heritage · 2006
2. Decree: evaluation and mitigation of the seismic risk of the Cultural Heritage with reference to the Technical Regulation, 14 January 2008 (in Italian)
3. Greek Earthquake Planning and Protection Organization · 2010
4. Recommendations for the analysis, conservation and structural restoration of architectural heritage
5. 2007
6. Investigation procedures for the diagnosis of historic masonries10.1016/S0950-0618(00)00018-0 ↗
7. Considerations on the significance of history for the structural analysis of ancient constructions
8. Structural analysis of masonry historical constructions. Classical and advanced approaches10.1007/s11831-010-9046-1 ↗
9. Magnani Pucci · 1997
10. Pre-diagnostic prompt investigation of a historic Bell Tower by visual inspection and microwave remote sensing
11. Post-earthquake diagnostic investigation of a historic masonry tower10.1016/j.culher.2014.09.002 ↗
12. Highspeed CW step-frequency coherent radar for dynamic monitoring of civil engineering structures10.1049/el:20040549 ↗
13. Output-only modal identification of a reinforced concrete bridge from radar-based measurements10.1016/j.ndteint.2008.04.005 ↗
14. Radar-based vibration measurement on historic masonry towers
15. System identification methods for (operational) modal analysis: review and comparison10.1007/s11831-012-9069-x ↗
16. Ambient vibration testing of historic masonry towers for structural identification and damage assessment10.1016/j.conbuildmat.2006.01.007 ↗
17. Structural identification of a masonry tower based on operational modal analysis10.1080/15583058.2014.951792 ↗
18. Post-earthquake continuous dynamic monitoring of the Gabbia Tower in Mantua, Italy10.1016/j.conbuildmat.2015.02.010 ↗
19. Dynamic investigation on a masonry bell tower10.1016/j.engstruct.2005.09.019 ↗
20. Dynamic behaviour of a medieval masonry bell tower. II. Measurement and modelling of the tower motion10.1061/(ASCE)0733-9445(2005)131:11(1656) ↗
21. Minaret behaviour under earthquake loading: the case of historical Istanbul10.1002/eqe.1115 ↗
22. Numerical models for the seismic assessment of an old masonry tower10.1016/j.engstruct.2010.01.027 ↗
23. Ambient vibration testing, dynamic identification and model updating of a historic tower10.1016/j.ndteint.2011.11.009 ↗
24. One-year monitoring of a historic bell tower
25. Modal identification of output-only systems using frequency domain de-composition10.1088/0964-1726/10/3/303 ↗
26. Operational modal testing of historic structures at different levels of excitation10.1016/j.conbuildmat.2013.01.013 ↗
27. Numerical assessment of three medieval masonry towers subjected to different loading conditions
28. Reference-based stochastic subspace identification for output-only modal analysis10.1006/mssp.1999.1249 ↗