Combination of the Wenner resistivimeter and Torrent permeameter methods for assessing carbonation depth and saturation level of concrete
Source abstract
Abstract
Abstract Assessing carbonation depth is of great interest for the diagnosis of reinforced concrete structures because carbonation is one of the origins of steel corrosion. The assessment of carbonation depth is usually performed by a simple and reliable semi-destructive test consisting in spraying a colored indicator on a sample extracted from the structure. When the structure is large, this test must be reproduced many times if an assessment of the variability of carbonation depth is required. In this case, the extraction of multiple samples can be prohibitive from the technical and economic points of view. So, in this case, a non-destructive testing (NDT) method could be relevant. However, even when NDT methods can be used, there is a need to improve the interpretation of their results. In this study, the use of two usual NDT methods is proposed: resistivity measurement by a Wenner probe and surface permeability assessment by a Torrent permeameter. Both techniques are implemented on carbonated slabs having different carbonated depths and at different saturation degrees. The results show that the two techniques are sensitive to moisture and carbonation. For a given saturation level, resistivity increases when the carbonated depth increases and resistivity decreases when the saturation level increases. Torrent permeability decreases when the saturation degree and carbonated depth increase. Good repeatability is observed for resistivity measurements while a larger scatter is obtained for Torrent permeability. Empirical laws are built for the relationships between resistivity or permeability and saturation degree and carbonated depth. For resistivity, either a linear model between resistivity and saturation degree is used or Archie’s law is adapted to take the effect of carbonation into account. Following the same idea, a linear law between Torrent permeability and saturation degree is adapted to the effect of carbonation. Because resistivity can be measured only if the saturation degree is rather high, i.e. if there is a continuity of the interstitial solution, and because permeability assessment is impossible if the concrete is fully saturated, these laws are limited to saturation degrees in the 40–83% range. Then, these laws are used to predict carbonation depth and saturation degree on a wall designed with the same concrete but stored in different conditions. The results show that resistivity and Torrent permeability can be used for the combined assessment of carbonation depth and saturation degree in laboratory conditions.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Geophysical Methods and Applications · Concrete Corrosion and Durability · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (54)
Show source-provided references
1. Experimental investigation of the variability of concrete durability properties10.1016/j.cemconres.2012.11.002 ↗
2. Gas permeability of concrete in relation to its degree of saturation10.1007/BF02480405 ↗
3. Chemical composition of cement pore solutions10.1016/0008-8846(89)90022-7 ↗
4. The electrical resistivity log as an aid in determining some reservoir characteristics10.2118/942054-G ↗
5. Baroghel-Bouny · 2004
6. Bungey · 2006
7. Impact of carbonation on unsaturated water transport properties of cement-based materials10.1016/j.cemconres.2015.04.002 ↗
8. Non destructive assessment of in-situ concrete strength: comparison of approaches through an international benchmark
9. Suitability of several current used concrete durability indices on evaluating the corrosion hazard for carbonated concrete10.1016/j.matchemphys.2003.10.016 ↗
10. The experimental investigation of concrete carbonation depth10.1016/j.cemconres.2004.07.025 ↗
11. Influence of traversing crack on chloride diffusion into concrete10.1016/j.cemconres.2007.10.007 ↗
12. Effect of uniaxial compressive loading on gas permeability and chloride diffusion coefficient of concrete and their relationship10.1016/j.cemconres.2013.05.013 ↗
13. Electromagnetic non-destructive evaluation techniques for the monitoring of water and chloride ingress into concrete: a comparative study10.1617/s11527-013-0189-z ↗
14. M. Fares, G. Villain, S. Bonnet, S. Palma Lopes, B. Thauvin, M. Thiery, Determining chloride content profiles in concrete using a resistivity probe, submitted to Cement and concrete Composites in September 2017.10.1016/j.cemconcomp.2018.08.001 ↗
15. Gas permeability and electrical conductivity of structural concretes: impact of pore structure and pore saturation10.1016/j.cemconres.2016.08.009 ↗
16. A model to predict service life of concrete structures
17. Influence of mineral admixtures on compressive strength, gas permeability and carbonation of high performance concrete10.1016/j.conbuildmat.2008.08.021 ↗
18. Assessment of liquid water and gas permeabilities of partially saturated ordinary concrete10.1016/j.conbuildmat.2014.04.137 ↗
19. Electrical resistivity measurement applied to cracking assessment on reinforced concrete structures in civil engineering10.1016/S0963-8695(03)00013-6 ↗
20. Quantification and uncertainty analysis of a structural monitoring device: detection of chloride in concrete using DC electrical resistivity measurement10.1080/10589759.2015.1029476 ↗
21. Investigation of liquid water and gas permeability of partially saturated cement paste by DEM approach10.1016/j.cemconres.2016.02.002 ↗
22. Influence of the degree of pore saturation on the resistivity of concrete and the corrosion of steel reinforcement10.1016/0008-8846(93)90102-F ↗
23. Compressive strength and electrical properties of concrete with white Portland cement and blast-furnace slag10.1016/j.cemconcomp.2011.11.017 ↗
24. Prediction of the relative permeability to gas flow of cement-based materials10.1016/S0008-8846(03)00071-1 ↗
25. A new model for predicting the unsaturated hydraulic conductivity of porous media10.1029/WR012i003p00513 ↗
26. Characterizing enhanced porosity concrete using electrical impedance to predict acoustic and hydraulic performance10.1016/j.cemconres.2006.09.001 ↗
27. About the statistical interpretation of air permeability assessment results10.1617/s11527-011-9780-3 ↗
28. Assessing concrete carbonation resistance through air permeability measurements10.1016/j.conbuildmat.2015.02.075 ↗
29. Effects of carbonation on pore structure and diffusional properties of hydrated cement pastes10.1016/S0008-8846(97)00102-6 ↗
30. Nguyen · 2006
31. Estimation of reinforcement electrochemical state in water-saturated reinforced concrete by resistivity measurement, Constr. Build. Mater. 171 (2018), 455–466.10.1016/j.conbuildmat.2018.01.155 ↗
32. A reaction engineering approach to the problem of concrete carbonation10.1002/aic.690351008 ↗
33. Effect of fly ash on Portland cement systems: Part I. Low-calcium fly ash10.1016/S0008-8846(99)00153-2 ↗
34. Effect of fly ash on Portland cement systems: Part II. HIGH-calcium fly ash10.1016/S0008-8846(00)00388-4 ↗
35. Effect of axial compressive damage on gas permeability of ordinary and high-performance concrete10.1016/S0008-8846(01)00546-4 ↗
36. Test methods for on site measurement of resistivity of concrete – a RILEM TC-154 Technical Recommendation10.1016/S0950-0618(00)00061-1 ↗
37. Measurement of hardened concrete carbonation depth
38. Effect of moisture and concrete composition on the Torrent permeability measurement10.1007/BF02479545 ↗
39. The carbonation of concrete and the mechanism of moisture, heat and carbon dioxide flow through porous materials10.1016/0008-8846(93)90030-D ↗
40. Effect of moisture, chloride and sulphate contamination on the electrical resistivity of Portland cement concrete10.1016/0950-0618(95)00078-X ↗
41. Monitoring the evolution of material structure in cement pastes and concretes using electrical property measurements10.1016/j.conbuildmat.2013.08.038 ↗
42. Capillary porosity depercolation in cement-based materials: measurement techniques and factors which influence their interpretation10.1016/j.cemconres.2011.04.006 ↗
43. Non-destructive and on site method to assess the air- permeability in dimension stones and its relationship with other transport-related properties10.1617/s11527-014-0440-2 ↗
44. Using radar direct wave for concrete condition assessment: correlation with electrical resistivity10.1016/j.jappgeo.2007.02.003 ↗
45. Effect of mixing proportions of concrete on its electrical conductivity and the rapid chloride permeability test (ASTM C1202 or ASSHTO T277) results10.1016/j.cemconres.2003.09.007 ↗
46. A new meta-model to calculate carbonation front depth within concrete structures10.1016/j.conbuildmat.2016.10.103 ↗
47. Application of sensitivity analysis in the life cycle design for the durability of reinforced concrete structures in the case of XC4 exposure class10.1016/j.cemconcomp.2017.11.024 ↗
48. Non-destructive evaluation of cracks in massive concrete using normal dc resistivity10.1016/j.ndteint.2014.01.001 ↗
49. A two-chamber vacuum cell for measuring the coefficient of permeability to air of the concrete cover on site10.1007/BF02472595 ↗
50. Measuring the gas permeability as a function of saturation rate of concretes
51. Gammadensimetry: a method to determine drying and carbonation profiles in concrete10.1016/j.ndteint.2005.10.002 ↗
52. Performance-based design and carbonation of concrete with high fly ash content10.1016/j.cemconcomp.2011.07.005 ↗
53. Thermal stability and decomposition mechanisms of ettringite at <120 °C10.1016/S0008-8846(01)00558-0 ↗
54. Permeability characteristics of carbonated concrete considering capillary pore structure10.1016/j.cemconres.2007.03.011 ↗