journal article·2012-10

Out-of-plane behavior of unreinforced masonry brick walls strengthened with CFRP strips

Özgür Anil, Muhammed Tatayoğlu, Murat Demirhan

Publisher page

Abstract

Abstract In many experimental studies, it is proved that URM brick walls have high strength against lateral forces acting in-plane. However, out-of-plane strength of URM brick wall against lateral forces is quite low. Therefore an experimental study is designed for improving the out-of-plane strength of URM brick walls. Specimens are manufactured by using bricks with high hollow ratios and low compressive strengths and then CFRP materials are used for strengthening. The variables examined in the study are CFRP strip layouts and usage of CFRP anchorages. The performance of strengthening technique is determined by examining strength, stiffness, ductility, energy dissipation capacity and failure modes. ACI 440 Committee report is used for calculation of the capacity of the specimens. The technique of strengthening with CFRP strips increased the strength of the specimens 9 times, ductility ratio 3.5 times; energy dissipation capacity 125 times compared to URM masonry walls.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Structural Behavior of Reinforced Concrete · Seismic Performance and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. Out of plane behavior of surface-reinforced masonry wall10.1016/S0950-0618(02)00024-7 ↗
2. Out of plane strength of brick masonry retrofitted with horizontal NSM CFRP strip10.1016/j.engstruct.2009.10.015 ↗
3. Teng · 2002
4. Oehlers · 2004
5. Cyclic flexure tests of masonry walls reinforced with glass fiber reinforced polymer sheets10.1061/(ASCE)1090-0268(2003)7:1(20) ↗
6. Strengthening with FRP bars of URM walls subject to out-of-plane loads10.1016/j.conbuildmat.2005.06.047 ↗
7. Strengthening of unreinforced masonry walls using FRPs10.1061/(ASCE)1090-0268(2001)5:2(76) ↗
8. Damaged masonry walls in two-way bending retrofitted with vertical FRP strips10.1016/j.conbuildmat.2007.09.007 ↗
9. Rehabilitation of masonry walls using unobtrusive FRP techniques for enhanced out-of-plane seismic resistance10.1061/(ASCE)1090-0268(2006)10:3(213) ↗
10. Behavior of retrofitted URM walls under simulated earthquake loading10.1061/(ASCE)1090-0268(1999)3:3(134) ↗
11. Shear behavior of URM retrofitted with FRP overlays10.1061/(ASCE)1090-0268(1997)1:1(17) ↗
12. Flexural capacity of glass FRP strengthened composite masonry walls10.1061/(ASCE)1090-0268(2001)5:3(170) ↗
13. Strengthening of masonry structures using epoxy bonded FRP laminated10.1061/(ASCE)1090-0268(1998)2:2(96) ↗
14. ACI Committee 440. State-of-the-art report on fiber reinforced plastic (FRP) reinforcement for concrete structures. Detroit, Michigan: American Concrete Institute; 2001. p. 68 [26.10.01].