Abstract
Abstract Glass fibre-reinforced polymer (GFRP) tubes are compared to steel spiral reinforcement in circular concrete members with longitudinal reinforcement and prestressing, using six beam tests. Two 324 mm diameter and 4.2 m long prestressed specimens were tested in bending. Four 219 mm diameter reinforced specimens were also tested, including two 2.43 m long beams tested in bending and two 0.6 m long beams tested in shear. In each set, one specimen was essentially a concrete-filled GFRP tube, while the other control specimen included steel spiral reinforcement of comparable hoop stiffness to that of GFRP tube. The strength of control specimens was governed by crushing and spalling of concrete cover. Unlike spiral reinforcement, GFRP tubes confined larger concrete areas and also contributed as longitudinal reinforcement, leading to increases in flexural and shear strengths, up to 113% and 69%, respectively.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. Zhao L, Burgueño R, Rovere HL, Seible F, Karbhari VM. Preliminary evaluation of the hybrid tube bridge system. Report No. TR-2000/4, Department of Structural Engineering, University of California, San Diego, CA; 2004. p. 1–56.
2. Pando M, Fam A, Lesko J, Filz G. New bridge piers using load bearing concrete-filled gfrp tubes. Field application of FRP reinforcement: case studies, ACI SP-215-10; 2003, p.181–200.
3. Concrete encased in fibreglass-reinforced plastic
4. Behavior of concrete columns confined by fiber composites10.1061/(ASCE)0733-9445(1997)123:5(583) ↗
5. Behavior of axially loaded concrete-filled circular fiber reinforced polymer tubes
6. Observed stress–strain behavior of confined concrete10.1061/(ASCE)0733-9445(1988)114:8(1827) ↗
7. Large scale testing and analysis of hybrid concrete/composite tubes for circular beam-column applications10.1016/S0950-0618(03)00048-5 ↗
8. Burgueno R, Bhide K. Shear stresses in concrete-filled FRP cylindrical shells in bending. In: Proceedings of the 4th advanced composite materials in bridges and structures, Calgary, Canada; 2004, p. 1–8.
9. Ahmad I. Shear response and bending fatigue behavior of concrete-filled fiber reinforced polymer tubes. Ph.D. Thesis. North Carolina State University; 2004, p. 219.
10. Daniel · 1994
11. Mandal SK. Prestressed concrete-filled fiber reinforced polymer tubes. M.Sc. Thesis. Queen’s University, Kingston, Ont., Canada; 2004. p. 204.
12. Cole BL. Flexural and shear performances of reinforced concrete-filled fibre reinforced polymer tubes. M.Sc. Thesis. Queen’s University, Kingston, Ont., Canada; 2005. p. 201.