Experimental investigation of the residual mechanical properties of cast steels after exposure to elevated temperature
Source abstract
Abstract
Abstract Cast steel is extensively used in civil engineering, especially for complex joints in spatial steel structures. Provided that local or global structural collapse of structures that incorporate cast steel structural elements and joints does not occur during or immediately after a fire event, the post-heating residual behavior of the steel castings in steel structures must be accurately characterized to estimate the remaining structural capacity and resulting safety. An experimental investigation was undertaken to explore the post-heating residual mechanical properties of two widely used structural cast steels, namely G20Mn5N and G20Mn5QT. Tensile coupon tests were performed on specimens after exposure to one of 13 preselected maximum temperatures (up to 1000 °C). Both air cooling and water cooling methods were considered, and residual mechanical properties, such as stress–strain curves, elastic modulus, yield strength, ultimate strength, and fracture strains were obtained for both types of cast steel. Additional tests were undertaken to investigate the effects of cyclic heating and cooling. The mechanical properties of both cast steels began to change after exposure to temperatures exceeding approximately 700 °C. With increasing exposure temperatures, up to 1000 °C, G20Mn5N showed maximum variations of approximately 28.6%, 14.8%, and 57% in yield strength, ultimate strength, and fracture strains, respectively; while the corresponding variations for G20Mn5QT were less severe at 16.8%, 7.6%, and 45%, respectively. The influence of different cooling methods was considerable, particularly when the exposure temperature exceeded 700–750 °C, whereas the effects of cyclic heating and cooling appeared to be insignificant. Predictive empirical equations to evaluate the post-heating mechanical properties of the two cast steels studied herein are proposed for both air and water cooling.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Load-Bearing Analysis · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. Some key techniques for the design of connections of structural steel casting
2. Fire design model for structural steel S355 based upon transient state tensile test results10.1016/S0143-974X(97)00018-7 ↗
3. Fire design model for structural steel S420M based upon transient-state tensile test results10.1016/S0143-974X(98)00005-4 ↗
4. Outinen · 2001
5. Behavior of high strength structural steel at elevated temperatures10.1061/(ASCE)0733-9445(2006)132:12(1948) ↗
6. Experimental investigation of cold-formed steel material at elevated temperatures10.1016/j.tws.2006.11.003 ↗
7. Experimental study of the mechanical properties of light gauge cold-formed steels at elevated temperatures10.1016/j.firesaf.2008.06.006 ↗
8. Effect of temperature on mechanical properties of prestressing bars10.1016/j.conbuildmat.2014.03.001 ↗
9. Elevated temperature material properties of cold-formed steel hollow sections10.1016/j.tws.2015.01.007 ↗
10. Mechanical properties and design recommendations of very high strength steel S960 in fire10.1016/j.engstruct.2016.01.008 ↗
11. BS 5950. Structural use of steelwork in building. Part 8: code of practice for fire resistant design. Institution BS, 2003.
12. Eurocode 3. Design of steel structures. Part 1–2: general rules-structural fire design. CEN, 2005.
13. Post-fire behavior of slender reinforced concrete columns confined by circular steel tubes10.1016/j.tws.2014.10.014 ↗
14. B.R. Kirby, D.G. Lapwood, G. Thomson, The reinstatement of fire damaged steel and iron framed structures. (Technical Report), British Steel Swinden Laboratories, London, UK, 1993.
15. Experimental investigation into the post-fire mechanical properties of hot-rolled and cold-formed steels10.1016/j.jcsr.2016.03.005 ↗
16. Mechanical properties of structural steel at elevated temperatures and after cooling down10.1002/fam.849 ↗
17. Experimental investigation of post-fire mechanical properties of cold-formed steels10.1016/j.tws.2014.06.010 ↗
18. Post-fire mechanical properties of high strength structural steels S460 and S69010.1016/j.engstruct.2011.11.005 ↗
19. Post-fire performance of very high strength steel S96010.1016/j.jcsr.2012.09.002 ↗
20. Mechanical properties of heat-treated high strength steel under fire/post-fire conditions10.1016/j.jcsr.2014.02.003 ↗
21. Mechanical properties of ultra-high strength (Grade 1200) steel tubes under cooling phase of a fire: an experimental investigation10.1016/j.conbuildmat.2015.05.082 ↗
22. Experimental study on the post-fire mechanical properties of high-strength steel tie rods10.1016/j.jcsr.2016.03.004 ↗
23. Residual behavior of steel rebars and R/C sections after a fire10.1016/j.conbuildmat.2009.06.050 ↗
24. Stress-strain curves of structural and reinforcing steels after exposure to elevated temperatures10.1061/(ASCE)MT.1943-5533.0000676 ↗
25. Behavior of prestressing steels after a simulated fire: fire-induced damages10.1016/j.conbuildmat.2009.02.024 ↗
26. Post-fire deterioration and prestress loss in steel tendons used in post-tensioned slabs
27. DIN EN 10293. Steel castings for general engineering uses. CEN, 2005.
28. GB/T 228–2010. Metallic material-tensile testing. Part 1: Method of test at room temperature. Standards Press of China, 2010.
29. GB/T 4338–2010. Metallic material-tensile testing at elevated temperature. Standards Press of China, 2010.
30. GB 50045–95. Code for fire protection design of tall buildings. Standards Press of China, 2005.
31. GB/T 22315–2008. Metallic material-Determination of modulus of elasticity and Poisson’s ratio. Standards Press of China, 2008.