journal article·2017-11

Residual strength of high strength concentric column-SFRC flat plate exposed to high temperatures

Farid H. Arna'ot, Ahmmad A. Abbass, Ahmed Abbas Abualtemen, Sallal R. Abid, Mustafa Özakça

Publisher page

Abstract

Abstract It became well known that steel fibers could significantly improve the mechanical properties of concrete and the ductility of flat plat-column assembly at ambient conditions. The investigation of the contribution of the steel fiber and the high strength concrete under high temperature conditions on the structural behavior of flat plates is still in need. This research presents experimental results of sixteen steel fiber reinforced slabs exposed to four levels of temperature reaching 550 °C, in addition to four control slab specimens. The residual mechanical properties, ultimate slab strength, and deformations were investigated. Relations between the concrete tensile and compressive strengths after exposing to high temperatures were introduced. For all temperature levels and steel fiber contents, the strength of most of the slabs was improved compared to the corresponding strength at room temperature. The highest percentage improvement was recorded for specimens exposed to 150 °C and reinforced with 1% of steel fiber. The strengths of the slabs with 1% and 1.25% of steel fiber and exposed to 550 °C were almost the same as their strengths at ambient conditions, however, slabs with 0.75% showed 13% increase.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Experimental study on the steel-fibre contribution to concrete shear behaviour10.1016/j.conbuildmat.2016.02.157 ↗
2. K. Kordina, Über das brandverhalten punktgestützter stahlbetonplatten. On the Fire Behavior of Reinforced Concrete Flat Slabs, Berlin , Heft 479, 1997.
3. P. Bamonte, M. F. Ruiz, A. Muttoni, Punching shear strength of R/C slab subjected to fire, Proceedings of the 7th International Conference on Structures in Fire - SiF2012, Zurich, 2012, pp. 689–698.
4. Thermo-mechanical analysis of an underground car park structure exposed to fire10.1016/j.firesaf.2012.07.006 ↗
5. Reinforced concrete wall and column footings
6. Punching of concrete slabs without shear reinforcement
7. J. Moe, Shearing strength of reinforced concrete slab and footing under concentrated loads, Port. Cem. Ass., Bull. D47, Illinois, 1961.
8. Simplified model for estimating the punching resistance of reinforced concrete slabs10.1007/BF02472716 ↗
9. Tests of column-flat plate connections
10. Ultimate punching shear strength analysis of slab-column connections10.1016/S0958-9465(01)00067-1 ↗
11. C.E. Broms, Concrete flat slabs and footings design method for punching and detailing for ductility, Royal Inst. Tech. Stockholm, Ph.D Thesis, 2005.
12. Punching shear strength of reinforced concrete slabs without transverse reinforcement
13. Punching shear strength of reinforced concrete flat slabs subjected to fire on their tension side10.1016/j.hbrcj.2011.10.001 ↗
14. Punching shear tests on flat concrete slabs exposed to fire10.1016/j.firesaf.2012.10.013 ↗
15. Fire resistance of concrete slabs in punching shear
16. Smith · 2015
17. Punching shear behavior of concrete flat slabs in elevated temperature and fire10.1260/1369-4332.18.5.659 ↗
18. Similarities between punching and shear strength of steel fiber reinforced concrete (SFRC) slabs and beams
19. Influence of steel and/or polypropylene fibres on the behaviour of concrete at high temperature: spalling, transfer and mechanical properties10.1016/j.conbuildmat.2016.11.120 ↗
20. Steel fibers as only reinforcement for flat slab construction – experimental investigation and design10.1016/j.conbuildmat.2011.06.004 ↗
21. Punching shear behavior of reinforced slab-column connections made with steel fiber concrete
22. Splitting tensile strength of steel fiber reinforced concrete cylinders consolidated by rodding or vibrating
23. Analysis of fire resistance of concrete with polypropylene or steel fibers10.1016/j.conbuildmat.2016.06.055 ↗
24. Effect of high temperatures on high performance steel fibre reinforced concrete10.1016/j.cemconres.2006.03.024 ↗
25. Experimental research for the effect of high temperature on the mechanical properties of steel fiber-reinforced concrete10.1016/j.conbuildmat.2014.11.005 ↗
26. Effects of high temperature on the- residual compressive strength of high-strength siliceous concretes
27. Discussion: residual fracture properties of normal- and high-strength concrete subject to elevated temperatures10.1680/macr.2000.52.2.123 ↗
28. Compressive behavior of steel fiber reinforced recycled aggregate concrete after exposure to elevated temperatures10.1016/j.conbuildmat.2014.08.012 ↗
29. Compressive behavior of fiber reinforced high-performance concrete subjected to elevated temperatures10.1016/j.cemconres.2004.02.011 ↗
30. J.R. Lawson, T. Phanl, F. Davis, Mechanical Properties of High Performance Concrete after Exposure to Elevated Temperatures, National Institute of Standard and Technology, Gaithersburg, NISTIR 6475, 2000.10.6028/NIST.IR.6475 ↗
31. P. Bamonte, R. Felicetti, Fire scenario and structural behaviour of underground parking lots exposed to fire, in Proceeding of International Conferance Applications of structural Fire Engineering, session 2 Fire Modelling, Prague, 2009, pp. 60–65.
32. Analysis of vehicle fire statistics in New Zealand parking buildings10.1007/s10694-006-0004-2 ↗
33. S.D.B Alexander, H. Simmonds, Shear-moment transfer in column-slab connections, Civil Eng. Univ.Alberta, SEI-Rep 141 (1986) pp. 95.
34. ACI318-14, Building code requirements for structural concrete, American Concrete Institute, ACI committee 318; 2014.
35. Australian Standards, Concrete structures, Sydney, Australia, (AS3600), 2009.
36. Canadian standards association, Design of concrete structures, Canada, (CSA A23.3), 2004.
37. Bureau of Indian standards, Plain and reinforced code of practice, New Delhi, India, (IS456-Fourth Revision), 2000.
38. German Standards, Concrete, reinforced and prestressed concrete structures- Part 1: Design and construction, Deutsches Institut für Normung, Berlin, Germany, (DIN1045-1), 2008.
39. European Committee for Standardization. Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings, (EN1992-1-1), Brussels, 2004.
40. Jirsa, Two-way shear strength of slab-column connections: reexamination of ACI 318 provisions
41. Punching tests of slabs with low reinforcement ratios
42. Addressing punching failure
43. TS500, Requirements for design and construction of reinforced concrete structures. Ankara, TUBITAK, 2000 (in English).
44. H. Gesund, Y. P. Kaushik, Analysis of punching shear failures in slabs, International Association for Bridge and Structu. Eng. J. 30-I (1970) pp. 41–60.
45. Steel fibre reinforced concrete at elevated temperature
46. Dehydration kinetics of portland cement paste at high temperature10.1007/s10973-012-2303-9 ↗
47. ACI216R-89, Guide for determining the fire endurance of concrete elements, American Concrete Institute, ACI committee 216; 1989 Reapproved 1994.
48. European Committee for Standardization. Eurocode 2: Design of concrete structures- part 1-2: General rules—structural fire design, (EN1992-1-2), Brussels, 2004.
49. High-temperature mechanical properties of concrete
50. Effect of elevated temperature on splitting tensile strength of fibre concrete10.1016/0262-5075(89)90090-0 ↗
51. SNIP2.03.01-84, Concrete and reinforced concrete structures, SNIP 2.03.01-84, 1997 Edition.
52. Stress–strain constitutive equations of concrete material at elevated temperatures10.1016/j.firesaf.2005.06.003 ↗
53. Relationship of the punching shear capacity of reinforced concrete slabs with concrete strength