journal article·2018-06

Electrochemical chloride extraction (ECE) based on the high performance conductive cement-based composite anode

Zuquan Jin, Dongshuai Hou, Tiejun Zhao

Publisher page

Abstract

Abstract The chloride ions, imbibition in the reinforcement concrete, are detrimental to the durability of the material. In this paper, a low shrinkage and high ductile conductive cement-based mortar was developed as a novel external anode for electrochemical chloride extraction (ECE). The electricity resistivity, fracture energy and drying shrinkage of mortar with different length, volume fraction of carbon fiber were investigated to optimize mix proportion of conductive cement base mortar (CCM). Subsequently, the proposed CCM with good performance was then utilized as the anode to remove the chloride ions electrochemically from three types of reinforced concrete. The chloride ions distribution in concrete and CCM anode were obtained to evaluate the electrochemical chloride extraction (ECE) efficiency. Additionally, the microstructures, elements distribution and calcium hydroxide content of CCM anode and ITZ were achieved for the further mechanism investigation. Experimental results indicated that the ECE efficiency for CCM anode was as high as that of traditional stainless mesh anode. The CCM anode with 0.8% volume fraction of carbon fiber exhibits excellent ductile and conductivity performance. Furthermore, CCM anode thickness influences significantly on the chloride removal efficiency and residual chloride proportion in concrete and CCM anode. And 10 mm thickness of CCM anode was a suitable value to ECE treatment of reinforced concrete. The microstructure and calcium hydroxide content in CCM anode showed no degradation after 35 days of ECE treatment, which indicated that the CCM anode have an excellent cracking resistance capacity and could be re-used.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Smart Materials for Construction · Concrete Corrosion and Durability · Concrete and Cement Materials Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Initial corrosion presented by chloride threshold penetration of concrete up to 10 year-results under marine site10.1016/j.conbuildmat.2012.07.061 ↗
2. Interaction between compressive load and corrosive-ion attack on reinforced concrete with accelerated potentiostatic corrosion10.1016/j.conbuildmat.2016.03.115 ↗
3. Corrosion and 3D crack-propagation behaviors in reinforced concrete subjected to bending load in simulated marine environment10.20964/2016.10.26 ↗
4. Effect of reinforcement corrosion on bond behavior10.1016/j.proeng.2013.09.038 ↗
5. Time-dependent performance of concrete surface coatings in tidal zone of marine environment10.1016/j.conbuildmat.2011.11.044 ↗
6. Epoxy-coated bars as corrosion control in cracked reinforced concrete10.1002/maco.201106319 ↗
7. Tidal water effect on the hybrid cathodic protection systems for marine concrete structures10.3151/jact.10.389 ↗
8. Strategies to ensure durability of concrete structure for Hangzhou Bay Bridge
9. Environmental condition and durability of lining concrete in Kiaochow bay subsea tunnel
10. Chloride-induced corrosion of steel in concrete10.1002/pse.54 ↗
11. D.R. Lankard, J.E. Slater, W.A. Hedden, D.E. Niesz, Neutralisation of Chloride in Concrete, Report No. FHWA-RD-76-60, Batelle Columbus Laboratories, Federal Highway Administration (USA), 1975, pp. 1–143.
12. Electrochemical chloride extraction (ECE) from steel-reinforced concrete specimens contaminated by “artificial” sea-water10.1016/j.corsci.2004.11.015 ↗
13. Factors influencing electrochemical removal of chloride from concrete10.1016/0008-8846(96)00067-1 ↗
14. The inhibitive effects of electrochemical treatment applied to steel in concrete10.1016/S0010-938X(99)00121-3 ↗
15. Electrochemical chloride extraction: efficiency and side effects10.1016/j.cemconres.2003.07.001 ↗
16. Böhni · 2005
17. J. Mietz, Electrochemical Rehabilitation Methods for Reinforced Concrete Structures, A State of the Art Report, European Federation of Corrosion Publications No. 24, London.
18. Electrochemical chloride removal in reinforced concrete structures: improvement of effectiveness by simultaneous migration of silicate ion10.1016/j.conbuildmat.2016.09.137 ↗
19. Application of carbon-fiber-reinforced polymer anode in electrochemical chloride extraction of steel-reinforced concrete10.1016/j.conbuildmat.2016.05.103 ↗
20. J.-H. Zhu, M. Zhu, N. Han, F. Xing, W. Liu, L. Bertolini, Behavior of CFRP plate in simulated ICCP system of concrete structures, in: Proceedings of 4th International Conference on the Durability of Concrete Structures, Purdue University, West Lafayette, Indiana, USA, 2014.10.5703/1288284315424 ↗
21. Conductivity of carbon fiber reinforced cement-based composites10.1016/S0958-9465(02)00138-5 ↗
22. The electrically conductive carbon nanotube (CNT)/cement composites for accelerated curing and thermal cracking reduction10.1016/j.compstruct.2016.09.014 ↗
23. Thermal characteristics of a conductive cement-based composite for a snow-melting heated pavement system10.1016/j.compstruct.2014.07.021 ↗
24. Cathodic protection of steel reinforced concrete facilitated by using carbon fiber reinforced mortar or concrete10.1016/S0008-8846(97)00058-6 ↗
25. Effectiveness of a conductive cementitious mortar anode for cathodic protection of steel in concrete10.1016/j.cemconres.2003.10.018 ↗
26. Efficiency of a conductive cement-based anodic system for the application of cathodic protection, cathodic prevention and electrochemical chloride extraction to control corrosion in reinforced concrete structures10.1016/j.corsci.2015.04.012 ↗
27. Feasibility of electrochemical chloride extraction from structural reinforced concrete using a sprayed conductive graphite powder–cement paste as anode10.1016/j.corsci.2013.07.035 ↗
28. Electrochemical extraction of chlorides from reinforced concrete using a conductive cement paste as the anode10.1016/j.corsci.2010.01.016 ↗
29. Key parameters of constructed lining concrete in Jiaozhou Bay Subsea Tunnel
30. Strain and damage sensing properties on multifunctional cement composites with CNF10.1016/j.cemconcomp.2013.11.009 ↗
31. Interaction between sulfate and chloride solution attack of concrete with and without fly ash10.1016/j.cemconres.2007.02.016 ↗