Strength assessment of old masonry arch bridges through moderate destructive testing methods
Source abstract
Abstract
Abstract This paper aims to assess the strength of a 100 + year old masonry arch bridges in Australia that are currently in operation and routinely subjected to train loadings. Towards this end, 45 cores of 150 mm diameter with varied lengths and joint configurations were drilled from a typical bridge and tested. Out of these samples, 30 were tested under direct compression and 15 were tested for tensile strength with varying bed joint angles. The samples for compression testing were regularised by developing high strength mortar capping whereas, the samples for tensile strength were tested according to Brazilian testing method commonly used for evaluating the splitting tensile strength of materials. The typical failure mode of masonry under compression was due to vertical cracking in bricks, spalling and cracking in perpend joints. The average compressive strength of masonry was determined as 10.6 MPa. Young’s modulus was also determined with a magnitude of 11,048 MPa which is comparable to an in-situ flat jack test conducted on the similar bridges. The increased number of perpend joints in masonry cores decreased the masonry compressive strength. Splitting tests revealed the average tensile strength of 1.34 MPa. From the results it can be concluded that the aged masonry used in the arch bridge has a higher strength than previously thought of and that the bridge seems to be capable of sustaining the current train loads, as observed at site.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Structural Health Monitoring Techniques · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (49)
Show source-provided references
1. Experimental characterization of the mechanical behaviour of components and materials of stone masonry railway bridges10.1016/j.conbuildmat.2017.07.069 ↗
2. Experimental identification of a multi-span masonry bridge: the Tanaro Bridge10.1016/j.conbuildmat.2007.07.031 ↗
3. The use of small diameter cores for assessing the compressive strength of clay brick masonries10.1016/j.culher.2012.11.027 ↗
4. Experimental research of masonry compressive strength in the Auschwitz II - Birkenau former death camp buildings10.1016/j.engfailanal.2016.06.007 ↗
5. Determination of shear strength of historic masonries by moderately destructive testing of masonry cores10.1016/j.conbuildmat.2013.12.039 ↗
6. Compression test of masonry core samples extracted from existing brickwork10.1016/j.conbuildmat.2016.05.057 ↗
7. Mechanical characterization of historical masonry by core drilling and testing of cylindrical samples
8. Cylindrical samples of brick masonry with aerial lime mortar under compression: experimental and numerical study10.1016/j.conbuildmat.2019.116782 ↗
9. Combining Brazilian tests on masonry cores and double punch tests for the mechanical characterization of historical mortars10.1016/j.conbuildmat.2016.02.168 ↗
10. Core testing method to assess nonlinear behavior of brick masonry under compression: a comparative experimental study10.1016/j.conbuildmat.2019.04.188 ↗
11. Serviceability assessment of masonry arch bridges using digital image correlation10.1061/(ASCE)BE.1943-5592.0001341 ↗
12. UIC-778-3, 1995. International Union of Railways. 1995. Leaflet.“ lEAFLET 778-3r, Recommendations for the inspection, assessment and maintenance of masonry arch bridges. Paris, France.
13. Experimental analysis of the size effect on the compressive behaviour of cylindrical samples core-drilled from existing brick masonry10.1016/j.conbuildmat.2019.116759 ↗
14. Failure analysis of masonry arch bridges subject to local pier scour10.1016/j.engfailanal.2017.05.028 ↗
15. A framework for assessing the seismic risk map of Italy and developing a sustainable risk reduction program10.1016/j.ijdrr.2018.09.012 ↗
16. Structural analysis of a multi-span railway masonry bridge combining in situ observations, laboratory tests and damage modelling10.1016/j.engstruct.2013.05.052 ↗
17. Assessment of masonry arch railway bridges using non-destructive in-situ testing methods10.1016/j.engstruct.2009.04.008 ↗
18. Modal properties variation and collapse assessment of masonry arch bridges under scour action10.1016/j.engstruct.2019.109665 ↗
19. Compressive strength of solid clay brick masonry: calibration of experimental tests and theoretical issues
20. Effect of moisture condition on mechanical behavior of low strength brick masonry10.1016/j.jobe.2018.01.015 ↗
21. RILEM TC 177-MDT, 'Masonry durability and on-site testing' - RILEM Recommendation MDT. D.4 - In-situ stress tests based on the flat jack. Mater. Struct. 37(271) (2004) 491–496.10.1617/14119 ↗
22. Masonry evaluation using flat Jack method
23. A. Simões, A. Gago, M. Lopes, R. Bento, Characterization of old masonry walls: flat-jack method, in: Proceedings of 15th World Conference on Earthquake Engineering, SPES, Lisbon, edited, 1–10.
24. Performance evaluation of a stone masonry-arch railway bridge under increased axle loads10.1061/(ASCE)CF.1943-5509.0000407 ↗
25. In situ flat-jack testing of traditional masonry walls: case study of the old city center of Coimbra, Portugal10.1080/15583058.2013.855840 ↗
26. Assessment of the mechanical properties of brick masonry by a flat-jack method
27. Experimental calibration of flat jacks for in-situ testing of masonry10.1080/15583058.2018.1453886 ↗
28. A flat jacks method for in situ testing of brick masonry shear characteristics10.1016/j.conbuildmat.2020.119840 ↗
29. Mechanical characterization of masonry walls with flat-Jack tests10.1007/s40799-016-0114-9 ↗
30. Mechanical behaviour of ancient masonry10.1617/s11527-008-9372-z ↗
31. A review of experimental investigations and assessment methods for masonry arch bridges10.1080/15732479.2015.1136655 ↗
32. Historical brick-masonry subjected to double flat-jack test: acoustic emissions and scale effects on cracking density10.1016/j.conbuildmat.2009.03.003 ↗
33. Tube-jack testing for irregular masonry walls: prototype development and testing
34. Tube-Jack testing for irregular masonry walls: regular masonry wall testing10.1007/s10921-016-0360-x ↗
35. M. Westley, J. Parrott, Arch structures load ratings of main south line brick arch bridges, ARTC Report Group 2 (2016).
36. Masonry arches: historical rules and modern mechanics10.1080/15583050701312926 ↗
37. A generalised damage model for masonry under compression10.1177/1056789516656745 ↗
38. Prediction of masonry compressive behaviour using a damage mechanics inspired modelling method10.1016/j.conbuildmat.2016.01.048 ↗
39. Material characterisation of thin layer mortared clay masonry10.1016/j.conbuildmat.2019.116932 ↗
40. On the in-plane shear response of the high bond strength concrete masonry10.1617/s11527-017-1078-7 ↗
41. Effects of joint thickness adhesion and web shells to the face shell bedded concrete masonry loaded in compression10.7158/S12-035.2013.14.3 ↗
42. Flexural and shear bond characteristics of thin layer polymer cement mortared concrete masonry10.1016/j.conbuildmat.2013.04.002 ↗
43. AS3700:2018, Masonry structures, Standards Australia, BD-004, Sydney, 2018.
44. ASTM, Standard Test Method for Splitting Tensile Strength of Intact Rock Core Specimens, edited by D. Soil and Rock, 2008.
45. V. Ponnampalam, H. Madrio, E. Ancich, New life for old masonry arch bridges, Sustainable Bridges: The Thread of Society, AP-G90/11_080, ABC Australia, 2011.
46. A non-local transient-gradient enhanced damage modelling method incorporating variable Poisson’s ratio for brittle bi-material composites
47. An explicit finite element modelling method for masonry walls under out-of-plane loading10.1016/j.engstruct.2016.01.026 ↗
48. Characterisation and strategies for mitigation of the contact surface unevenness in dry-stack masonry10.1016/j.conbuildmat.2018.03.002 ↗
49. Interfacial transition zone modelling for characterisation of masonry under biaxial stresses