Expected render performance assessment based on impact resistance in situ determination
Source abstract
Abstract
Abstract External renders must fulfil certain functions to ensure a good in-service performance of facades such as: waterproofing and protection of the walls, finishing of the surfaces, durability in face of the external degradation agents, and adequacy to use. Defective surface resistance of the renders (significant deterioration under impact and friction actions inherent to the normal use of the building) accelerates the degradation process, leading to a significant loss of physical and aesthetical performance. Based on laboratory experimental testing and on-site investigation, with various types of renders and using the Martinet-Baronnie device, the parameters of surface resistance are discussed, in terms of resistance to the impact of hard objects (with and without cutting edges). The results allowed criteria to be proposed for the in situ assessment of external renders in buildings with brick masonry walls (characterization of predicted surface impact resistance in-service conditions).
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Building materials and conservation · Conservation Techniques and Studies · 3D Surveying and Cultural Heritage
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. National Statistics Institute (INE). National statistics – census 2001 [02.07.04, in Portuguese].
2. Veiga, R. Behaviour of façades coatings with a mineral binder. Functional demands and performance evaluation. In: Proceedings of the 1st national congress national on construction mortars. Lisbon: APFAC (CD ROM); 2005 [in Portuguese].
3. CEN. EN 998-1. Specification for mortar for masonry. Part 1: rendering and plastering mortar. Brussels: European Committee for Standardization; 2003.
4. LNEC. Bases for the homologation of pre-dosed coatings with mineral cement-based binder. Report 289/95 – NCCt, Portuguese National Laboratory of Civil Engineering, Lisbon; 1995 [in Portuguese].
5. Crescêncio RM. Evaluation of the performance of a one-coat decorative mortar. Masters dissertation, São Paulo University, Brazil; 2003. p. 170 [in Portuguese].
6. ISO. ISO 7361 – Performance standards in building – presentation of performance levels of façades made of same-source components. International organization for standardization, Switzerland; 1986.
7. BCIS. Life expectancy of buildings components. Surveyor’s experiences of building in use – a practical guide. London: Building Cost Information Service; 2001. p. 164.
8. Lucas J. Coatings for internal surfaces of masonry walls in blocks of cellular autoclaved concrete. Specialist thesis, Portuguese National Laboratory of Civil Engineering, Lisbon; 1983 [in Portuguese].
9. Uzac R, Vigier J, Baronnie P. Essais de qualification des surfaces peintes. Cahier 695, Centre Scientifique et Technique du Bâtiment (CSTB); 1966 [in Portuguese].
10. Magalhães AC, Veiga MR. Comparison of in situ mechanical tests on masonry mortars: sphere impact and controlled penetration test. In: Proceedings of the heritage, weathering & conservation conference, HWC 2006, Madrid; 2006.
11. Stains in façades rendering – diagnosis and maintenance techniques classification10.1016/j.conbuildmat.2006.08.023 ↗
12. Expedient in situ test techniques for predictive maintenance of rendered façades10.1057/palgrave.jba.2940047 ↗
13. Flores-Colen I. Methodology of evaluation of the in-service performance of rendered façades from the predictive maintenance point of view. PhD thesis in Civil Engineering, IST, Technical University of Lisbon, Lisbon, Portugal; 2009. p. 488 [in Portuguese].
14. CMHC. Assessing the impact of thickness on the performance of stucco cladding. Research highlight, Technical series 04-123, Ottawa, Ontario, Canada. [30.11.05].
15. LNEC. UEATc Directives related to impacts in vertical opaque construction elements. ICT translation 769. Lisbon: LNEC; 1982. p. 24 [in Portuguese].
16. EOTA. Determination of impact resistance of panels and panel assemblies. Technical report TR001, European organisation for technical approvals; 2003.
17. ISO · 1988
18. CSTB/ MELTM. Manuel des performances, Tome I, La structure, l’enveloppe verticale. Centre Scientifique et Technique du Bâtiment (CSTB); 1989. p. 151.
19. ABNT. Performance of dwelling buildings with up to five pavements – Part 4: Facades and partition walls. Brazilian Association of Technical Norms; 2002 [in Portuguese].
20. Thorogood RP. Resistance of external walls to impacts from hard objects: Research leading to requirements and an assessment technique. In: Proceedings of the 3rd ASTM/CIB/RILEM symposium, vol. 1. Lisbon: LNEC; 1982. p. 203–12.
21. CEN · 2005
22. Veiga MR, Aguiar J, Silva AS, Carvalho F. Conservation and renovation of coatings of ancient buildings walls. Collection conservation and rehabilitation of buildings. Lisbon: LNEC; 2004. p. 126 [in Portuguese].
23. RILEM. Characterization of the surface strength of renderings by the pendulum ball test. RILEM technical recommendation MR1-19, E&FN SPON; 1982.
24. Influence of the kneading water content in the behaviour of single-coat mortars10.1016/j.cemconres.2005.04.011 ↗
25. CEN · 2006
26. CEN · 2000
27. NF B10-631
28. Flores-Colen I, de Brito J, Freitas V. Condition assessment of façade rendering through in situ testing. In: Proceedings of 11th DBMC international conference on durability of building materials and components, Istanbul, Turkey; 2008, CD.
29. ASTM · 2006
30. CEN · 2002
31. Recommendation MDT D. 3. Determination in situ of the adhesive strength of rendering and plastering mortars to their substrate10.1617/14118 ↗
32. A new technique for the measurement of the impact resistance of wall coatings10.1016/S0008-8846(01)00505-1 ↗
33. CSTB · 1993