Abstract An experimental study was taken to investigate the cumulative seismic damage of reinforced concrete columns with or without steel corrosion and to evaluate the effect of using CFRP wraps on the seismic behavior of the columns. Eleven identical rectangular reinforced concrete columns were constructed and tested under standard cyclic loads with variable drift amplitudes or low-cycle fatigue loads at different constant drift amplitudes. The column models included five un-corroded columns and six columns corroded using an external current method. Test results indicate that steel corrosion reduces the strength, ductility, low-cycle fatigue life, and cumulative energy dissipation capacity of reinforced concrete columns under cyclic loads, whereas the use of CFRP wraps greatly improves the above-mentioned behavior except the strength of un-corroded and corroded columns. The corroded column with a steel corrosion level of about 10% and retrofitted using CFRP wraps exhibited lower loading capacity but much better ductility and cumulative energy dissipation capacity than un-corroded columns. The seismic damage indexes of the columns with or without steel corrosion were also estimated based on the Park–Ang damage model and the relationships between damage indexes and experimental observations were discussed.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Structural Behavior of Reinforced Concrete · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Structural assessment of corroded reinforced concretebeams: modeling guidelines10.1061/(ASCE)0733-9445(2004)130:8(1214) ↗
2. Residual flexure capacity of corroded reinforced concrete beams10.1016/j.engstruct.2006.07.018 ↗
3. Flexural strength of concrete beams with corroding reinforcement
4. Fatigue flexural behavior of corroded reinforced concrete beams repaired with CFRP sheets10.1061/(ASCE)CC.1943-5614.0000144 ↗
5. Fatigue performance of RC beams strengthened in shear with CFRP fabrics10.1061/(ASCE)CC.1943-5614.0000095 ↗
6. Flexural behavior of continuous FRP-reinforced concrete beams10.1061/(ASCE)CC.1943-5614.0000140 ↗
7. Flexural behavior of GFRP-reinforced concrete encased steel composite beams10.1016/j.conbuildmat.2011.08.058 ↗
8. Corrosion performance of epoxy-coated reinforcing steel: North American experience10.1016/0950-0618(95)00028-3 ↗
9. Prefabricated composite jacketing of RC columns for enhanced shear strength10.1061/(ASCE)0733-9445(1999)125:3(255) ↗
10. Seismic retrofitting of rectangular reinforced concrete columns using fiber composites for enhanced flexural strength10.1177/0731684413477222 ↗
11. Teng · 2002
12. An experimental study on the retrofitting effects of reinforced concrete columns damaged by rebar corrosion strengthened with carbon fiber sheets10.1016/S0008-8846(02)01004-9 ↗
13. Behavior of corrosion damaged circular reinforced concrete columns under cyclic loading10.1016/j.conbuildmat.2011.11.002 ↗
14. Experimental evaluation of the corrosion influence on the cyclic behavior of RC columns10.1016/j.engstruct.2014.06.043 ↗
15. Fiber-reinforced polymer retrofitting of rectangular reinforced concrete columns with or without corrosion
16. Seismic retrofitting of corroded reinforced concrete columns using carbon composites
17. Seismic behavior of corrosion-damaged reinforced concrete columns strengthened using combined carbon fiber-reinforced polymer and steel jacked10.1016/j.conbuildmat.2009.01.003 ↗
18. Jin · 2011
19. GB/T 50081. Standard for Test Method of Mechanical Properties on Ordinary Concrete. Beijing (China), China Architecture and Industry Press, 2002. (In Chinese).
20. Eurocode 2. Design of concrete structures—Part 1: general rules and rules for buildings. British standards institution, 1999.
21. GB/T 228. Metallic Materials-tensile Testing at Ambient Temperature, Beijing (China), Standards Press of China, 2002. (In Chinese).
22. Mechanistic seismic damage model for reinforced concrete10.1061/(ASCE)0733-9445(1985)111:4(722) ↗
23. Seismic damage indices for concrete structures: state-of- the-art review10.1193/1.1585817 ↗
24. Cumulative seismic damage of circular bridge columns: benchmark and low-cycle fatigue tests
25. Low-cycle fatigue damage of circular concrete filled tube columns
26. Seismic damage performance design of reinforced concrete structures based on improved capacity spectrum method
27. Mechanical properties of corrosion-damaged reinforcement
28. FIB. Displacement-based seismic design of reinforced concrete buildings, International Federation for Structural Concrete, 2003.
29. Theoretical stress-strain model for confined concrete10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗