Seismic response of PP-band and FRP retrofitted house models under shake table testing
Source abstract
Abstract
Abstract Current research work presents the seismic response of brick masonry houses retrofitted by different composite materials under dynamic shake table tests. Tests were performed on 1:4 scaled unreinforced masonry (URM), Polypropylene (PP-band) retrofitted, Glass Fiber Reinforced Polymer (FRP) retrofitted and FRP + PP-band retrofitted house models. A minimum reinforcement ratio of FRP was selected to use with PP-band as FRP + PP-band composite. Results show that URM is highly brittle and can hardly withstand an ordinary ground motion, whereas PP-band retrofitting has increased the ability of URM houses to withstand a severe ground motion with intense cracking and separation of wall segments. However, despite no collapses, PP-band retrofitted house model had lost its serviceability when subjected to strong input ground motion. Unlike PP-band, FRP retrofitted houses were collapsed suddenly without giving any warning with respect to ductility and energy dissipation. The sudden failure of FRP houses is attributed to very low FRP reinforcement ratio (0.0006), as it is an expensive material and its sole use in higher amounts would result in significant increase of retrofitting costs. Results show that a potential use of FRP in combination with PP-band is a good alternative as it significantly enhances the shear capacity, energy dissipation as well as the ductility of URM masonry structure at a very low retrofitting costs.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Structural Behavior of Reinforced Concrete · Seismic Performance and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Shaking table study of single-story masonry houses. UCB/EERC 79/25;1979.
2. Verification of seismic resistance of confined masonry building10.1002/(SICI)1096-9845(199710)26:10<1073::AID-EQE695>3.0.CO;2-Z ↗
3. Shaking table tests on 24 simple masonry buildings10.1002/(SICI)1096-9845(199801)27:1<67::AID-EQE719>3.0.CO;2-K ↗
4. Behaviour of masonry in filled steel frames10.1139/l89-129 ↗
5. Shaking table tests of 1:4 reduced scale models of masonry infilled reinforced concrete frame buildings10.1002/eqe.39 ↗
6. H.X. Li, S. Zhang, X. Hu, M. Zhang, Seismic performance of masonry structures strengthened with FRP laminates: a shaking table study. In: Proceedings of the 15th World Conference on Earthquake Engineering (15th WCEE), Lisbon, Portugal; 2012. [CD-ROM].
7. M. Alcocer, G. Arias, A. Vazquez, Response assessment of Mexican confined masonry structures through shaking table tests. In: Proceedings of the 13th World Conference on Earthquake Engineering (13th WCEE), Vancouver, Canada; 2004. p 2130.
8. Shake table testing of posttensioned concrete masonry walls with openings10.1061/(ASCE)0733-9445(2007)133:11(1551) ↗
9. Out-of-plane shake table tests on unreinforced masonry panels in RC frames10.1016/j.engstruct.2010.08.030 ↗
10. Shaking table study of a single storey confined brick masonry building
11. Shake table tests of a three story reinforced concrete frame with masonry infill walls
12. Shake-table experiment on reinforced concrete structures containing masonry infill wall10.1002/eqe.612 ↗
13. U. Moritz, S. Lothar, Comparison of different earthquake strengthening methods for masonry buildings. In: Proceeding of the 15th World Conference (15th WCEE): Earthquake Engineering, Lisbon (Portugal) 2012. [CD-ROM].
14. Shake table tests on one-quarter scale models of masonry houses retrofitted with PP-band mesh10.1193/1.3675357 ↗
15. Seismic behavior of low earthquake-resistant arch-shaped roof masonry houses retrofitted by PP-band meshes10.1061/(ASCE)SC.1943-5576.0000113 ↗
16. Strengthening of adobe houses with arch roofs using tie-bars and polypropylene band mesh10.1016/j.conbuildmat.2015.02.071 ↗
17. Experimental investigation on the seismic performance of masonry buildings using shaking table testing10.1007/s10518-012-9410-7 ↗
18. Optimum quantity of fiber reinforced polymers for cost effective seismic retrofitting of masonry structures
19. E.C. Carvalho, Seismic testing of structures. In: Proceedings of the 11th European Conference on Earthquake Engineering, Paris, France; 1998.
20. P. Candeias, A.C. Costa, E. Coelho, Shaking table tests of 1:3 reduced scale models of four story unreinforced masonry buildings. In: Proceedings of the 13th World Conference on Earthquake Engineering (13th WCEE). Vancouver, Canada; 2004.
21. Seismic assessment of masonry “Gaioleiro” buildings in Lisbon10.1080/13632460902977474 ↗
22. Some aspects of experimental testing of seismic behavior of masonry walls and models of masonry buildings10.63898/IYNS2369 ↗
23. Seismic upgrading of old masonry buildings by seismic isolation and CFRP laminates: a shaking-table study of reduced scale models10.1007/s10518-008-9086-1 ↗
24. Seismic evaluation of earthquake resistance and retrofitting measures for two story masonry houses10.1007/s10518-014-9587-z ↗
25. C. Loaiza, M. Blondet, G. Ottazzi, World housing encyclopedia report. Earthquake Engineering Research Institute, the International Association for Earthquake Engineering. Engineering Information Foundation, John A. Martin & Associates Inc, 2003.
26. S.M. Lodi, A.J. Sangi, A. Abdullah, World housing encyclopedia report. Earthquake Engineering Research Institute, the International Association for Earthquake Engineering. Engineering Information Foundation, John A. Martin & Associates Inc, 2013.
27. Modeling concrete masonry building structures at one-quarter scale
28. N. Sathiparan, P. Mayorca, K. Nesheli, G. Ramesh, K. Meguro, In-plane and out-of-plane behavior of PP-band retrofitted masonry panels. In: Proceedings of the 4th International Symposium: New Technologies for Urban Safety of Mega Cities in Asia; 2005. pp. 231–40.
29. P. Mayorca, K. Meguro, Proposal of a methodology to design PP-band meshes to retrofit low earthquake resistant houses. Seisan Kenkyu, Bimonthly Journal of Institute of Industrial Science, University of Tokyo 2008;60(2):124–127
30. Saleem · 2013
31. 1998 · vol. 15
32. Applied element simulation of RC structures under cyclic loading10.1061/(ASCE)0733-9445(2001)127:11(1295) ↗
33. P. Mayorca, K. Meguro, Proposal of a new economic retrofitting method for masonry structures. In: Proceedings of the 27th JSCE Symposium of Earthquake Engineering, Fukushima, Japan; 2003.
34. K. Worakanchana, P. Mayorca, R. Guragain, S. Navaratnanaj, K. Meguro, 3-D applied element method for PP-band retrofitted masonry. In: Proceedings of the 14th World Conference on Earthquake Engineering (14th WCEE), Beijing, China; 2008.
35. Applied element method simulation of fiber reinforced polymer and polypropylene composite retrofitted masonry walls10.1260/1369-4332.17.11.1567 ↗
36. Damage model for the seismic response of brick masonry shear walls. Part 1: the mortar joint model and its application10.1002/(SICI)1096-9845(199704)26:4<423::AID-EQE650>3.0.CO;2-# ↗
37. Strengthening of masonry structures using epoxy bonded FRP laminates10.1061/(ASCE)1090-0268(1998)2:2(96) ↗