Behavior of post-tensioned dry-stack interlocking masonry walls under out of plane loading
Source abstract
Abstract
Abstract The researches done on wall construction to make it appropriate, easy, fast and cost effective have led to a promising technique known as “Dry-stack interlocking masonry system”. Nevertheless, there are several disadvantages attributed to using this system. One of the major drawbacks of this system is the low bending capacity that can be resisted by the interlocking keys alone. To overcome this problem grouting and reinforcing of the hollow block cells are required, which make the system a bit expensive. Additionally, the dry-stacked units had to settle down to balance uneven surfaces and notches, which may reduce strength and stiffness of the walls. One method that has been suggested to minimize this drawback is post-tensioning (PT) of these walls to eliminate grout and enhance the bending capacity. The objective of the current research is to investigate the behavior of PT dry-stacked interlocking masonry (DSIM) walls constructed using locally available masonry units and PT bars under out-of-plane loading. Some of the expected factors that could affect the performance of these systems are construction system, grouting effect, PT technique and restraining effect of PT bars. The test results demonstrated that PT-DSIM systems considered in the current study, under out-of-plane loading, behaved similar to the conventionally reinforced masonry walls. In addition, the proposed PT technique proved its efficiency for grouted walls. It can achieve a remarkable increase in the cracking load triple that of the ordinary reinforced walls and in addition to improving the durability and enhancing the appearance. Furthermore, ungrouted PT walls proved to be the most effective construction detail. Since, their specific strength (capacity/weight) ranges between 1.3 and 1.6 times that of grouted PT walls, in addition to taking the advantage of minimizing construction cost, time, and weight of the structure.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Building materials and conservation · Hygrothermal properties of building materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. E. Murray, Dry Stacked Surface Bonded Masonry -Structural Testing and Evaluation, (2007).
2. New masonry products and materials10.1002/1528-2716(200007/09)2:3<296::AID-PSE38>3.0.CO;2-6 ↗
3. Strength correlation between individual block, prism and basic wall panel for load bearing interlocking mortarless hollow block masonry10.1016/j.conbuildmat.2005.01.046 ↗
4. Development and evaluation of hollow concrete interlocking block masonry system10.70803/001c.130934 ↗
5. Mortarless masonry: the Mecano system
6. Drysdale · 1991
7. H. Harris, K. Oh, A. Hamid, Development of new interlocking and mortarless block masonry units for efficient building systems, Proc. 6th Can. Mason. (1992).
8. R. Drysdale, P. Eng, Properties of Azar dry-stack block-IV construction, (2005).
9. Mortarless block systems
10. Lateral strength of a dry-stack wall system
11. Development of an innovative interlocking load bearing hollow block system in Malaysia10.1016/j.conbuildmat.2004.03.013 ↗
12. Interlocking stabilised soil blocks: appropriate technology that doesn't cost the earth
13. J.R. Bean, C.R. Drake, A.E. Schultz, Strength and Stability of Slender, Post-Tensioned Concrete Masonry Walls Under Transverse Loading, (2004).
14. The load-bearing behavior of dry-stacked post-tensioned masonry
15. Standard specification for mortar for unit masonry
16. Restraint effectiveness in unbonded tendons for prestressed masonry
17. Masonry Standards Joint Committee, Building Code Requirements and Specification for Masonry Structures, 2011.
18. J. Edwards, M. Gayed, M. Pyra, T. Rodriguez, Design and Construction of Interlocking Mortarless Block Masonry, 2nd Mason. Mini Sysposium. (2010).
19. C. ASTM, 1314 · 2003
20. Structural behavior of an interlocking masonry block