Design of the shear strengthening of masonry walls with fabric reinforced cementitious matrix
Source abstract
Abstract
Abstract Fabric reinforced cementitious matrix (FRCM) composites are widely used for retrofitting existing structures, especially in earthquake prone areas. After nearly two decades of scientific studies, experimental evidence proves their effectiveness for enhancing the ultimate strength and displacement capacity of masonry walls. There remains a need to develop design guidelines for use in rehabilitation practice. This paper proposes a method for the design of the shear strengthening of masonry walls with FRCM, and provides the calibration of the partial coefficients for the calculation of the ultimate limit state. The design relationships are validated on the basis of an experimental database that includes 72 tests and are suitable for engineering purposes. The possibility of applying the same design format to the walls strengthened with composite reinforced mortar (CRM) is investigated, by considering 54 additional tests and comparing to FRCM retrofitted ones. Finally, the enhancement of displacement capacity achieved with FRCM and CRM, which is particularly useful for seismic retrofitting, is estimated, and a design value for the ultimate drift capacity is provided.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Building materials and conservation · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. FRCM strengthening—A new tool in the concrete and masonry repair toolbox
2. Mortar-based systems for externally bonded strengthening of masonry10.1617/s11527-014-0360-1 ↗
3. URM walls strengthened with fabric-reinforced cementitious matrix composite subjected to diagonal compression10.1061/(ASCE)CC.1943-5614.0000441 ↗
4. Shear capacity of masonry walls externally strengthened by a cement-based composite material: an experimental campaign10.1016/j.conbuildmat.2009.08.019 ↗
5. FRCM Strengthened masonry panels: the role of mechanical anchorages and symmetric layouts10.4028/www.scientific.net/KEM.747.334 ↗
6. Masonry reinforcement with IMG composites: experimental investigation10.4028/www.scientific.net/KEM.624.275 ↗
7. Experimental investigation of tuff masonry panels reinforced with surface bonded basalt textile-reinforced mortar10.1016/j.compositesb.2016.09.094 ↗
8. Shear behaviour of masonry panels strengthened by high strength steel cords10.1016/j.conbuildmat.2010.05.014 ↗
9. Experimental investigation of in-plane shear behaviour of grey clay brick masonry panels strengthened with SRG10.1016/j.engstruct.2018.02.027 ↗
10. ACI American Concrete Institute. ACI 549.6R-20: Guide to Design and Construction of Externally Bonded Fabric-Reinforced Cementitious Matrix (FRCM) and Steel-Reinforced Grout (SRG) Systems for Repair and Strengthening Masonry Structures. Farmington Hills, MI, USA, 2020
11. Diagonal compression tests on masonry walls strengthened with a GFRP mesh reinforced mortar coating10.1007/s10518-014-9684-z ↗
12. Experimental and analytical study to evaluate the effectiveness of an in-plane reinforcement for masonry walls using GFRP meshes10.1016/j.conbuildmat.2015.04.014 ↗
13. Analysis of FRCM and CRM parameters for the in-plane shear strengthening of different URM types10.1016/j.compositesb.2019.04.020 ↗
14. Shear strengthening of unreinforced masonry wall with different fiber reinforced mortar jacketing10.1016/j.conbuildmat.2015.10.095 ↗
15. American Concrete Institute. ACI 549.4R-13: Guide to design and construction of externally bonded Fabric-Reinforced Cementitious Matrix (FRCM) systems for repair and strengthening concrete and masonry structures. Farmington Hills, MI, USA, 2013.
16. National Research Council. CNR-DT 215/2018: Guide for the design and construction of Externally Bonded Fibre Reinforced Inorganic Matrix systems for strengthening existing structures. Rome 06/02/2019, version 6 February 2020
17. CEN European Committee for Standardization. EN1990. Eurocode 0: Basis of structural design. Brussels, BE, 2002
18. CEN European Committee for Standardization. EN1996. Eurocode 6: Design of masonry structures. Brussels, BE, 2005
19. American Society of Civil Engineers. ASCE 41-17. Seismic Evaluation and Retrofit of Existing Buildings. Reston, VA, US, 2017
20. Design of the out-of-plane strengthening of masonry walls with fabric reinforced cementitious matrix composites10.1016/j.conbuildmat.2019.117946 ↗
21. Experimental diagonal tension (shear) test of Un-Reinforced Masonry (URM) walls strengthened with textile reinforced mortar (TRM)10.1016/j.conbuildmat.2017.12.234 ↗
22. A. Balsamo, I. Iovinella, M. Di Ludovico, A. Prota, Experimental behavior of tuff masonry strengthened with lime matrix-grid composites. Proceedings of the 3rd International Workshop on Conservation of Heritage Structures Using FRM and SHM, CSHM-3, Ottawa-Gatrineau, Canada, August 11-13 2010, pp. 97-107
23. Effectiveness of inorganic matrix-grid composites for strengthening masonry walls
24. A. Balsamo, M. Di Ludovico, A. Prota, G. Manfredi, Masonry walls strengthened with innovative composites. Proceedings of the 10th International Symposium on Fiber-Reinforced Polymer Reinforcement for Concrete Structures, FRPRCS-10, American Concrete Institute, ACI Special Publication, 2011, 275, pp. 1-18.
25. Experimental in-plane behavior of tuff masonry strengthened with cementitious matrix–grid composites10.1061/(ASCE)1090-0268(2006)10:3(223) ↗
26. In-plane behaviour of tuff masonry strengthened with inorganic matrix–grid composites10.1016/j.compositesb.2012.09.068 ↗
27. European Organisation for Technical Assessment. European Assessment Document – EAD 340275-00-0104: Externally-bonded composite systems with inorganic matrix for strengthening of concrete and masonry structures. EOTA 2020
28. ICC Evaluation Service. AC434-16: Acceptance Criteria for Masonry and Concrete Strengthening Using Fabric-Reinforced Cementitious Matrix (FRCM) and Steel Reinforced Grout (SRG) Composite Systems. USA, 2016
29. Recommendation of RILEM technical committee 250-CSM: composites for sustainable strengthening of masonry. test method to characterize the Textile Reinforced Mortar to substrate bond behavior10.1617/s11527-018-1216-x ↗
30. Acceptance criteria for tensile characterization of Fabric Reinforced Cementitious Matrix (FRCM) systems for concrete and masonry repair10.1061/(ASCE)CC.1943-5614.0000886 ↗
31. Experimental and numerical study on the shear behavior of stone masonry walls strengthened with GFRP reinforced mortar coating and steel-cord reinforced repointing10.1016/j.engstruct.2015.02.024 ↗
32. Textile-reinforced mortar (TRM) versus FRP as strengthening material of URM walls: in-plane cyclic loading10.1617/s11527-006-9207-8 ↗
33. ASTM International. ASTM E519-07: Standard test method for diagonal tension (Shear) in masonry assemblages, West Conshohocken, PA, 2007
34. RILEM TC 76-LUM. LUM B6: Diagonal tensile strength tests of small wall specimens, 1991. In RILEM, Recommendations for the Testing and Use of Constructions Materials. E&FN SPON, London, UK, 1994. pp. 488–489
35. Identification of shear parameters of masonry panels through the in-situ diagonal compression test10.1080/15583050802138634 ↗
36. Shear behaviour of Fiber Reinforced Mortar strengthened masonry walls built with limestone blocks and hydraulic mortar
37. G. Mantegazza, A. Gatti, A. Barbieri, Retrofitting concrete and masonry building: FRCM (Fiber Reinforced Cementitious Matrix) a new emerging technology. Proceedings of the XII Konferencja Naukowo-Techniczna Problemy Remontowe W Budownictwie Ogólnym i Obiektach Zabytkowych REMO Conference, Poland, 2006.
38. G. Ferrara, Flax TRM composite systems for strengthening of masonry: from material identification to structural behavior (Ph.D. thesis) in Civil Engineering, University of Salerno and Claude Bernard Lyon 1 University, 2020
39. Structural behaviour of masonry panels strengthened with an innovative hemp fibre composite grid10.1016/j.conbuildmat.2015.09.051 ↗
40. Experimental in-plane shear capacity of clay brick masonry panels strengthened with FRCM and FRM composites10.1061/(ASCE)CC.1943-5614.0000965 ↗
41. In-Plane strengthening of clay brick and block masonry walls using Textile-Reinforced Mortar10.1061/(ASCE)CC.1943-5614.0000866 ↗
42. Influence of masonry texture on the shear strength of FRCM reinforced panels10.1007/978-3-319-99441-3_174 ↗
43. L. De Lorenzis, N. Galati, L. Ombres, In-plane shear strengthening of natural masonry walls with NSM CFRP strips and FRCM overlay. Proceeding of the 4th SAHC Conference, Modena, Italy, 2004
44. In-plane shear capacity of tuff masonry walls with traditional and innovative Composite Reinforced Mortars (CRM)10.1016/j.conbuildmat.2019.03.133 ↗
45. In situ diagonal compression tests on masonry panels strengthened by FRP and FRCM
46. Shear strengthening of wall panels through jacketing with cement mortar reinforced by GFRP grids10.1016/j.compositesb.2014.03.022 ↗
47. Polymer textiles as a retrofit material for masonry walls10.1680/stbu.11.00084 ↗
48. Lessons learned on the tensile and bond behavior of Fabric Reinforced Cementitious Matrix (FRCM) composites10.3389/fbuil.2020.00005 ↗
49. Applied Technology Council. FEMA 273: NEHRP Guidelines for the seismic rehabilitation of buildings. Basic procedures manual prepared for the Building Seismic Safety Council, Washington, DC, USA, 1997
50. Applied Technology Council. FEMA 306: Evaluation of earthquake damaged concrete and masonry wall buildings. Basic procedures manual prepared for the Partnership for Response and Recovery, Washington, DC, USA, 1998
51. Ministero delle Infrastrutture e dei Trasporti. DM 17/01/2018: Aggiornamento delle “norme tecniche per le costruzioni”. Gazzetta ufficiale della repubblica italiana n. 42 del 20/02/2018, Roma, Italia, 2018. (In Italian).
52. New Zealand Society of Earthquake Engineering. Assessment and improvement of the structural performance of buildings in earthquakes. University of Auckland, New Zealand, 2006
53. CEN European Committee for Standardization. EN 1998-3. Eurocode 8: Design of structures for earthquake resistance – Part 3: General rules, seismic actions and rules for buildings. Brussels, BE, 2002.
54. National Annex – Nationally determined parameters – Eurocode 8: Design of structures for earthquake resistance – Part 1: General rules, seismic actions and rules for buildings, National Annex of Germany, DIN EN 1998-1/NA: 2011- 01. Berlin, Germany, 2011.
55. Swiss Society of Engineers and Architects. SIA D0237: Evaluation de la sécurité parasismique des bâtiments en maçonnerie. Zürich, Switzerland, 2011. (In French).
56. Influence of boundary conditions and size effect on the drift capacity of URM walls10.1016/j.engstruct.2014.01.048 ↗
57. American Concrete Institute. ACI 440.7R-10: Guide for the design and construction of externally bonded Fiber-Reinforced Polymer systems for strengthening unreinforced masonry structures. Farmington Hills, MI, USA, 2010.