Experimental testing of damage-resistant rocking glulam walls with lead extrusion dampers
Source abstract
Abstract
Abstract When rocking structures are designed, dampers may be required to substitute conventional connections to provide load resistance and dissipate the rocking motion. This study investigates the applicability of High-Force-to-Volume (HF2V) damping devices in rocking timber structures. HF2V devices present an attractive solution since the device does not suffer stiffness or strength degradation and can be reused after an earthquake. Laboratory tests on loaded and unloaded timber walls using two HF2V devices per wall were carried out. The applicability of the devices in timber walls was investigated focusing on damper functioning, the influence of the vertical load on the self-centering behaviour of the dampers, and possible slip in all connections. The results show that the devices functioned as intended and no significant damage occurred in the devices or the timber walls. HF2V devices present a feasible solution for rocking timber walls when a damage free structural behaviour is aimed for.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Seismic Performance and Analysis · Masonry and Concrete Structural Analysis · Wood Treatment and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Rocking wall-frame structures with supplemental tendon systems10.1061/(ASCE)0733-9445(2004)130:6(895) ↗
2. HF2V dissipator effects on the performance of a 3 story moment frame10.1016/j.jcsr.2011.05.007 ↗
3. Experimental seismic behavior of a full-scale four-story soft-story wood-frame building with retrofits. I: Building design, retrofit methodology, and numerical validation
4. Multi-storey prestressed timber buildings in New Zealand10.2749/101686608784218635 ↗
5. New technologies for construction of medium-rise buildings in seismic regions: the XLAM case10.2749/101686608784218680 ↗
6. EN 12512, Timber structures – test methods – cyclic testing of joints made with mechanical fasteners, CEN, Brussels, Belgium, 2003.
7. Eurocode 5, Design of timber structures – Part 1-1: General – common rules and rules for buildings, EN 1995-1-1:2004, CEN, Brussels, Belgium, 2004.
8. M. Fragiacomo, C. Amadio, L. Sancin, G. Rinaldin, “Seismic analysis of a light-frame timber Building with and without friction pendulum base isolation.” World Conference of Timber Engineering WCTE2012, Auckland, New Zealand, 2012. (http://www.timberdesign.org.nz/files/00133%20Massimo%20Fragiacomo.pdf, accessed 22 June 2015).
9. The behaviour of inverted pendulum structures during earthquakes10.1785/BSSA0530020403 ↗
10. A.D. Latham, M.A. Reay, S. Pampanin, “Kilmore Street Medical Centre: application of a post-tensioned steel rocking system. Steel Innovations Conference, Christchurch, New Zealand, 2013. ( accessed 22 June 2015).
11. Damage avoidance design steel beam-column moment connection using high-force-to-volume dissipators10.1061/(ASCE)ST.1943-541X.0000065 ↗
12. Dynamic testing of precast, post-tensioned rocking wall systems with alternative dissipating solutions10.5459/bnzsee.41.2.90-103 ↗
13. Prefabricated stabilising timber walls anchored with glued-in rods – Experimental tests and preliminary design10.1007/s00107-013-0726-z ↗
14. Pei, S., Dolan, J.D., Liu, H., van de Lindt, J., Ricles, J.M. (2012). “Active damping for cross-laminated timber structures to improve seismic performance.” World Conference of Timber Engineering WCTE2012, Auckland, New Zealand. ( accessed 22 June 2015).
15. Fundamental considerations for the design of non-linear viscous dampers10.1002/(SICI)1096-9845(199911)28:11<1405::AID-EQE875>3.0.CO;2-A ↗
16. Experimental development, trade off analysis and design implementation of high force-to-volume damping technology10.5459/bnzsee.40.2.35-48 ↗
17. Spectral analysis and design approach for high force-to-volume extrusion damper-based structural energy dissipation10.1002/eqe.752 ↗
18. High-force to-volume seismic dissipators embedded in a jointed precast concrete frame10.1061/(ASCE)ST.1943-541X.0000329 ↗
19. Seismic analysis of an isolated and a non-isolated light-frame timber building using artificial and natural accelerograms
20. F. Sarti, A. Palermo, S. Pampanin, “Design Charts and Simplified Procedures for Post-Tensioned Seismic Resistant Timber Walls”, World Conference of Timber Engineering WCTE2012, Auckland, New Zealand, 2012.
21. Shaking table testing of a full-scale prefabricated three-story timber-frame building10.1080/13632469.2014.974291 ↗
22. Post-tensioned glue-laminated beam-column joints with advanced damping systems: testing and numerical analysis10.1080/13632469.2013.835291 ↗
23. “Experimental Seismic behavior of a full-scale four-story soft-story wood-frame building with retrofits. II: shake table test results”
24. D. Wrzesniak, W.G. Rodgers, M. Fragiacomo, G.J. Chase, “Damage avoidance design of timber structures using high-force-to-volume damping devices”. World Conference of Timber Engineering WCTE 2014, Quebec City, Canada, 2014
25. Wrzesniak · 2015