Understanding failure and stress-strain behavior of very-high strength concrete (>100 MPa) confined by lateral reinforcement
Source abstract
Abstract
Abstract An experimental program is carried out to evaluate the stress-strain behaviour and investigate the failure mechanisms of confined very-high strength concrete (VHSC) with compressive strengths of up to 160 MPa and lower confinement pressures in the range of 0.6–2.7 MPa. Even though post-peak behaviour of concrete is explained and modelled using the confinement effects, the study proposes that it can be explained by superposition of the shear strength behaviour at the failure plane of concrete, confinement effect, and dowelling action of steel. The stress-strain behaviour is further explained through a theoretical approach and it has good agreement with the experimental results.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Stress-strain model to predict the full-range moment curvature behaviour of high-strength concrete sections10.1680/macr.2000.52.4.227 ↗
2. Analytical moment-curvature relations for tied concrete columns10.1061/(ASCE)0733-9445(1992)118:2(529) ↗
3. Confinement reinforcement design for reinforced concrete columns10.1061/(ASCE)0733-9445(2008)134:5(738) ↗
4. Ductility design of high-strength concrete beams and columns10.1260/1369-4332.13.4.651 ↗
5. Flexural ductility design of high-strength concrete columns10.1002/tal.662 ↗
6. Inelastic design of low-axially loaded high-strength reinforced concrete columns10.1016/S0141-0296(03)00050-6 ↗
7. Confining reinforcement for concrete columns10.1061/(ASCE)0733-9445(1994)120:6(1798) ↗
8. High-Strength Concrete Columns Confined by Rectangular Ties10.1061/(ASCE)0733-9445(1994)120:3(783) ↗
9. B. Li, R. Park, H. Tanaka, Stress-strain behavior of high-strength concrete confined by ultra-high-and normal-strength transverse reinforcements. 2012.
10. Spacing of stirrups for high-strength concrete columns in ordinary moment resisting frames
11. Monotonic axial compression test on ultra-high-strength concrete tied columns
12. High-strength concrete columns with square sections under concentric compression10.1061/(ASCE)0733-9445(1998)124:12(1438) ↗
13. Confinement model for high-strength concrete10.1061/(ASCE)0733-9445(1999)125:3(281) ↗
14. Stress-strain relationship of confined and unconfined concrete
15. Mechanical properties of three high-strength concretes containing silica fume
16. A stress-strain model for uniaxial and confined concrete under compression10.1016/j.engstruct.2012.03.027 ↗
17. Enhancing the confinement of ultra-high-strength concrete columns using headed crossties10.1016/j.engstruct.2016.08.024 ↗
18. Uniaxial confinement model for normal- and high-strength concrete columns10.1061/(ASCE)0733-9445(2003)129:2(241) ↗
19. Design of high strength concrete members: state-of-the-art
20. Kristombu Baduge · 2016
21. AS/NZS 4671. Steel reinforcing materials. Sydney, Australia.: Standards Association of Australia; Standards Association of New Zealand; 2001.
22. ASTM A615/A615M-14. Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement. Philadelphia, United States: American Society for Testing and Materials; 2008.
23. Influence of concrete strength and transverse reinforcement yield strength on behavior of high-strength concrete columns
24. Theoretical stress-strain model for confined concrete10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
25. Campbell Scientific Australia. CR800-Series Dataloggers/CR800. Meas Control Datalogger 2016. https://www.campbellsci.com.au/cr800 (accessed January 20, 2016).
26. Tecnotest – Testing equipment for the Construction Industry 2016. http://www.tecnotest.it/pdfeng/eng%202.1%20concrete.pdf (accessed January 20, 2016).
27. AS 1012.8.1. Methods of testing concrete : Method for making and curing concrete : compression and indirect tensile test specimens. NSW, Australia: Standards Association of Australia; 2014.
28. ASTM C 469. Standard test method for static modulus of elasticity and Poisson’s ratio of concrete in compression. American Society for Testing and Materials; 2014.
29. Stress-strain model for confined high-strength concrete10.1061/(ASCE)0733-9445(1995)121:3(468) ↗
30. Strain localization in confined high-strength concrete columns10.1061/(ASCE)0733-9445(1996)122:9(1055) ↗
31. Stress-strain behavior of concrete confined by overlapping hoops at low and high strain rates
32. International Federation for Structural Concrete, editor. Model Code 2010. Lausanne: International Federation for Structural Concrete; 2010.
33. Ductility analysis of confined columns10.1061/(ASCE)0733-9445(1990)116:11(3148) ↗
34. Shear transfer in reinforced concrete