Axial compressive behavior of square concrete columns confined with CFRP strip ties using wet lay-up technique
Source abstract
Abstract
Abstract Pultruded fiber-reinforced polymer (FRP) bars used as confining reinforcement in concrete columns provide limited ductility and confinement efficiency due to the drastic reduction of strength at bend portions and premature bond slip failure at overlapping regions. In this study, complete close-type CFRP strip ties (C-S) with rectangular cross-section and fabricated using wet lay-up technique were proposed to overcome the shortcomings of pultruded FRP ties. Ten square concrete columns (300 × 300 × 900 mm), longitudinally reinforced with steel bars and confined with different types of ties such as steel, pultruded CFRP (C-P), and CFRP strip (C-S) ties, were tested to investigate their axial compressive behavior. Test results depicted that the columns confined with C-S ties exhibited improved confined concrete strength and ultimate axial strain in comparison with the columns confined with steel and C-P ties. Confined concrete strength and ultimate axial strain were increased up to 1.16 times and 3.5 times, respectively, by the replacement of C-P ties with the equal volumetric ratio of C-S ties.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. Tests of glass fibre reinforced polymer rectangular concrete columns subjected to concentric and eccentric axial loading10.1016/j.engstruct.2017.08.023 ↗
2. Cracking control comparison in the specifications of serviceability in cracking for FRP reinforced concrete beams10.1016/j.compstruct.2017.09.016 ↗
3. Behavior of concentrically loaded geopolymer-concrete circular columns reinforced longitudinally and transversely with GFRP bars10.1016/j.engstruct.2016.03.036 ↗
4. Axial load-axial deformation behaviour of circular concrete columns reinforced with GFRP bars and helices10.1016/j.conbuildmat.2016.02.219 ↗
5. Performance evaluation of concrete columns reinforced longitudinally with FRP bars and confined with FRP hoops and spirals under axial load10.1061/(ASCE)BE.1943-5592.0000590 ↗
6. Behavior of concentrically loaded fiber-reinforced polymer reinforced concrete columns with varying reinforcement types and ratios
7. Flexural performance of FRP reinforced concrete beams10.1016/j.compstruct.2011.12.012 ↗
8. Axial capacity of circular concrete columns reinforced with GFRP bars and spirals10.1061/(ASCE)CC.1943-5614.0000438 ↗
9. Strength and axial behavior of circular concrete columns reinforced with CFRP bars and spirals10.1061/(ASCE)CC.1943-5614.0000430 ↗
10. Concrete columns reinforced longitudinally and transversally with glass fiber-reinforced polymer bars
11. ACI, Guide, for the design and construction of structural concrete reinforced with fiber-reinforced polymer (FRP) bars, ACI Farmington Hills 2015 Michigan, USA.
12. Bend strength of FRP stirrups: comparison and evaluation of testing methods10.1061/(ASCE)CC.1943-5614.0000050 ↗
13. Bend strength of complete closed-type carbon fiber-reinforced polymer stirrups with rectangular section10.1061/(ASCE)CC.1943-5614.0000428 ↗
14. Bend-strength of novel filament wound shear reinforcement10.1016/j.compstruct.2017.05.032 ↗
15. Axial compressive behavior of square concrete columns reinforced with innovative closed-type winding GFRP stirrups10.1016/j.compstruct.2018.02.092 ↗
16. Behavior of concentrically loaded fiber-reinforced polymer reinforced concrete columns with varying reinforcement types and ratios
17. Mechanical and structural characterization of new carbon FRP stirrups for concrete members10.1061/(ASCE)1090-0268(2007)11:4(352) ↗
18. A.C. 440, Guide for the Design and Construction of Structural Concrete Reinforced with FRP Bars, American Concrete Institute, 2015.
19. Innovative hybrid reinforcement constituting conventional longitudinal steel and FRP stirrups for improved seismic strength and ductility of RC structures10.1007/s11709-015-0295-9 ↗
20. Experimental observation on the effectiveness of fiber sheet strip stirrups in concrete beams10.1061/(ASCE)CC.1943-5614.0000109 ↗
21. Shear capacity of RC beams with carbon fiber-reinforced polymer stirrups with rectangular section10.1061/(ASCE)CC.1943-5614.0000653 ↗
22. Wound FRP shear reinforcement for concrete structures10.1061/(ASCE)CC.1943-5614.0000807 ↗
23. S. ASTM, Standard specification for deformed and plain carbon-steel bars for concrete reinforcement, 2009.
24. Structural performance of axially loaded FRP-confined rectangular concrete columns as affected by cross-section aspect ratio
25. Path-dependent cyclic stress–strain relationship of reinforcing bar including buckling10.1016/S0141-0296(02)00080-9 ↗
26. Theoretical stress-strain model for confined concrete10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
27. Axial stress-strain model for square concrete columns internally confined with GFRP hoops
28. Reinforcement stability and fracture of cover concrete in reinforced concrete members10.1061/(ASCE)0733-9445(2002)128:10(1253) ↗
29. High-strength concrete columns confined by rectangular ties10.1061/(ASCE)0733-9445(1994)120:3(783) ↗